Reliability of the interpretation of coronary angiography by the simple visual method

Detalhes bibliográficos
Autor(a) principal: Guimarães,Jorge Augusto Nunes
Data de Publicação: 2000
Outros Autores: Victor,Edgar Guimarães, Leite,Maria do Rosário de Britto, Gomes,José Maria Pereira, Victor Filho,Edgar, Reyes Liveras,Jesus
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Arquivos Brasileiros de Cardiologia (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0066-782X2000000400001
Resumo: OBJECTIVE: Evaluation of inter and intraobserver reproducibility of by the visual method interpretation of cineangiogram in a clinically based context. METHODS: Five interventional cardiologists analyzed 11 segments of 8 coronary cineangiograms at a two month apart sessions. The percent luminal reduction by the lesions were analyzed by two different classifications: in one (A) the lesions were graded in 0% = absent, 1-50% = mild, 51 - 69 = moderate, and > or = 70% = severe; the other classification (B) was a dichotomic one : <70% = nonsignificant and > or = 70%=significant lesions. The agreement were measured by the kappa (k) index. RESULTS: Interobserver agreement was moderate for classification A (1st measurement, k = 0.36 -- 0.63, k m = 0.49; 2nd measurement, k = 0.39-0.68, k m = 0.52) and good for classification B (1st measurement, k = 0.55-0.73, k m = 0.63; 2nd measurement, k = 0.37-0.82, k m = 0.61). Intraobserver levels of agreement were k = 0.57-0.95 for classification A and 0.62-1.0 for classification B. CONCLUSION: The higher level of reproducibility obtained by adopting the dichotomous criteria usually considered for ischemic limits demonstrates that in the present clinical context, the reliability of the simple visual method is adequate for the identification of patients with clinically significant lesions and candidates for myocardial revascularization procedures.
id SBC-1_890eea2cbc79b6eb0e22181c61dcb019
oai_identifier_str oai:scielo:S0066-782X2000000400001
network_acronym_str SBC-1
network_name_str Arquivos Brasileiros de Cardiologia (Online)
repository_id_str
spelling Reliability of the interpretation of coronary angiography by the simple visual methodcoronary angiographyobserver variationkappa statisticOBJECTIVE: Evaluation of inter and intraobserver reproducibility of by the visual method interpretation of cineangiogram in a clinically based context. METHODS: Five interventional cardiologists analyzed 11 segments of 8 coronary cineangiograms at a two month apart sessions. The percent luminal reduction by the lesions were analyzed by two different classifications: in one (A) the lesions were graded in 0% = absent, 1-50% = mild, 51 - 69 = moderate, and > or = 70% = severe; the other classification (B) was a dichotomic one : <70% = nonsignificant and > or = 70%=significant lesions. The agreement were measured by the kappa (k) index. RESULTS: Interobserver agreement was moderate for classification A (1st measurement, k = 0.36 -- 0.63, k m = 0.49; 2nd measurement, k = 0.39-0.68, k m = 0.52) and good for classification B (1st measurement, k = 0.55-0.73, k m = 0.63; 2nd measurement, k = 0.37-0.82, k m = 0.61). Intraobserver levels of agreement were k = 0.57-0.95 for classification A and 0.62-1.0 for classification B. CONCLUSION: The higher level of reproducibility obtained by adopting the dichotomous criteria usually considered for ischemic limits demonstrates that in the present clinical context, the reliability of the simple visual method is adequate for the identification of patients with clinically significant lesions and candidates for myocardial revascularization procedures.Sociedade Brasileira de Cardiologia - SBC2000-04-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0066-782X2000000400001Arquivos Brasileiros de Cardiologia v.74 n.4 2000reponame:Arquivos Brasileiros de Cardiologia (Online)instname:Sociedade Brasileira de Cardiologia (SBC)instacron:SBC10.1590/S0066-782X2000000400001info:eu-repo/semantics/openAccessGuimarães,Jorge Augusto NunesVictor,Edgar GuimarãesLeite,Maria do Rosário de BrittoGomes,José Maria PereiraVictor Filho,EdgarReyes Liveras,Jesuseng2002-01-08T00:00:00Zoai:scielo:S0066-782X2000000400001Revistahttp://www.arquivosonline.com.br/https://old.scielo.br/oai/scielo-oai.php||arquivos@cardiol.br1678-41700066-782Xopendoar:2002-01-08T00:00Arquivos Brasileiros de Cardiologia (Online) - Sociedade Brasileira de Cardiologia (SBC)false
dc.title.none.fl_str_mv Reliability of the interpretation of coronary angiography by the simple visual method
title Reliability of the interpretation of coronary angiography by the simple visual method
spellingShingle Reliability of the interpretation of coronary angiography by the simple visual method
Guimarães,Jorge Augusto Nunes
coronary angiography
observer variation
kappa statistic
title_short Reliability of the interpretation of coronary angiography by the simple visual method
title_full Reliability of the interpretation of coronary angiography by the simple visual method
title_fullStr Reliability of the interpretation of coronary angiography by the simple visual method
title_full_unstemmed Reliability of the interpretation of coronary angiography by the simple visual method
title_sort Reliability of the interpretation of coronary angiography by the simple visual method
author Guimarães,Jorge Augusto Nunes
author_facet Guimarães,Jorge Augusto Nunes
Victor,Edgar Guimarães
Leite,Maria do Rosário de Britto
Gomes,José Maria Pereira
Victor Filho,Edgar
Reyes Liveras,Jesus
author_role author
author2 Victor,Edgar Guimarães
Leite,Maria do Rosário de Britto
Gomes,José Maria Pereira
Victor Filho,Edgar
Reyes Liveras,Jesus
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv Guimarães,Jorge Augusto Nunes
Victor,Edgar Guimarães
Leite,Maria do Rosário de Britto
Gomes,José Maria Pereira
Victor Filho,Edgar
Reyes Liveras,Jesus
dc.subject.por.fl_str_mv coronary angiography
observer variation
kappa statistic
topic coronary angiography
observer variation
kappa statistic
description OBJECTIVE: Evaluation of inter and intraobserver reproducibility of by the visual method interpretation of cineangiogram in a clinically based context. METHODS: Five interventional cardiologists analyzed 11 segments of 8 coronary cineangiograms at a two month apart sessions. The percent luminal reduction by the lesions were analyzed by two different classifications: in one (A) the lesions were graded in 0% = absent, 1-50% = mild, 51 - 69 = moderate, and > or = 70% = severe; the other classification (B) was a dichotomic one : <70% = nonsignificant and > or = 70%=significant lesions. The agreement were measured by the kappa (k) index. RESULTS: Interobserver agreement was moderate for classification A (1st measurement, k = 0.36 -- 0.63, k m = 0.49; 2nd measurement, k = 0.39-0.68, k m = 0.52) and good for classification B (1st measurement, k = 0.55-0.73, k m = 0.63; 2nd measurement, k = 0.37-0.82, k m = 0.61). Intraobserver levels of agreement were k = 0.57-0.95 for classification A and 0.62-1.0 for classification B. CONCLUSION: The higher level of reproducibility obtained by adopting the dichotomous criteria usually considered for ischemic limits demonstrates that in the present clinical context, the reliability of the simple visual method is adequate for the identification of patients with clinically significant lesions and candidates for myocardial revascularization procedures.
publishDate 2000
dc.date.none.fl_str_mv 2000-04-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0066-782X2000000400001
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0066-782X2000000400001
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S0066-782X2000000400001
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Cardiologia - SBC
publisher.none.fl_str_mv Sociedade Brasileira de Cardiologia - SBC
dc.source.none.fl_str_mv Arquivos Brasileiros de Cardiologia v.74 n.4 2000
reponame:Arquivos Brasileiros de Cardiologia (Online)
instname:Sociedade Brasileira de Cardiologia (SBC)
instacron:SBC
instname_str Sociedade Brasileira de Cardiologia (SBC)
instacron_str SBC
institution SBC
reponame_str Arquivos Brasileiros de Cardiologia (Online)
collection Arquivos Brasileiros de Cardiologia (Online)
repository.name.fl_str_mv Arquivos Brasileiros de Cardiologia (Online) - Sociedade Brasileira de Cardiologia (SBC)
repository.mail.fl_str_mv ||arquivos@cardiol.br
_version_ 1752126551254630400