Experimental Study and Early Clinical Application Of a Sutureless Aortic Bioprosthesis
Autor(a) principal: | |
---|---|
Data de Publicação: | 2015 |
Outros Autores: | , , , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Brazilian Journal of Cardiovascular Surgery (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-76382015000500515 |
Resumo: | ABSTRACT INTRODUCTION: The conventional aortic valve replacement is the treatment of choice for symptomatic severe aortic stenosis. Transcatheter technique is a viable alternative with promising results for inoperable patients. Sutureless bioprostheses have shown benefits in high-risk patients, such as reduction of aortic clamping and cardiopulmonary bypass, decreasing risks and adverse effects. OBJECTIVE: The objective of this study was to experimentally evaluate the implantation of a novel balloon-expandable aortic valve with sutureless bioprosthesis in sheep and report the early clinical application. METHODS: The bioprosthesis is made of a metal frame and bovine pericardium leaflets, encapsulated in a catheter. The animals underwent left thoracotomy and the cardiopulmonary bypass was established. The sutureless bioprosthesis was deployed to the aortic valve, with 1/3 of the structure on the left ventricular face. Cardiopulmonary bypass, aortic clamping and deployment times were recorded. Echocardiograms were performed before, during and after the surgery. The bioprosthesis was initially implanted in an 85 year-old patient with aortic stenosis and high risk for conventional surgery, EuroSCORE 40 and multiple comorbidities. RESULTS: The sutureless bioprosthesis was rapidly deployed (50-170 seconds; average=95 seconds). The aortic clamping time ranged from 6-10 minutes, average of 7 minutes; the mean cardiopulmonary bypass time was 71 minutes. Bioprostheses were properly positioned without perivalvar leak. In the first operated patient the aortic clamp time was 39 minutes and the patient had good postoperative course. CONCLUSION: The deployment of the sutureless bioprosthesis was safe and effective, thereby representing a new alternative to conventional surgery or transcatheter in moderate- to high-risk patients with severe aortic stenosis. |
id |
SBCCV-1_d55818897f7a572b2bdb7e6fe6e31fd4 |
---|---|
oai_identifier_str |
oai:scielo:S0102-76382015000500515 |
network_acronym_str |
SBCCV-1 |
network_name_str |
Brazilian Journal of Cardiovascular Surgery (Online) |
repository_id_str |
|
spelling |
Experimental Study and Early Clinical Application Of a Sutureless Aortic BioprosthesisAortic Valve, SurgeryHeart Valves, SurgeryAortic Valve StenosisBioprosthesisABSTRACT INTRODUCTION: The conventional aortic valve replacement is the treatment of choice for symptomatic severe aortic stenosis. Transcatheter technique is a viable alternative with promising results for inoperable patients. Sutureless bioprostheses have shown benefits in high-risk patients, such as reduction of aortic clamping and cardiopulmonary bypass, decreasing risks and adverse effects. OBJECTIVE: The objective of this study was to experimentally evaluate the implantation of a novel balloon-expandable aortic valve with sutureless bioprosthesis in sheep and report the early clinical application. METHODS: The bioprosthesis is made of a metal frame and bovine pericardium leaflets, encapsulated in a catheter. The animals underwent left thoracotomy and the cardiopulmonary bypass was established. The sutureless bioprosthesis was deployed to the aortic valve, with 1/3 of the structure on the left ventricular face. Cardiopulmonary bypass, aortic clamping and deployment times were recorded. Echocardiograms were performed before, during and after the surgery. The bioprosthesis was initially implanted in an 85 year-old patient with aortic stenosis and high risk for conventional surgery, EuroSCORE 40 and multiple comorbidities. RESULTS: The sutureless bioprosthesis was rapidly deployed (50-170 seconds; average=95 seconds). The aortic clamping time ranged from 6-10 minutes, average of 7 minutes; the mean cardiopulmonary bypass time was 71 minutes. Bioprostheses were properly positioned without perivalvar leak. In the first operated patient the aortic clamp time was 39 minutes and the patient had good postoperative course. CONCLUSION: The deployment of the sutureless bioprosthesis was safe and effective, thereby representing a new alternative to conventional surgery or transcatheter in moderate- to high-risk patients with severe aortic stenosis.Sociedade Brasileira de Cirurgia Cardiovascular2015-10-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-76382015000500515Brazilian Journal of Cardiovascular Surgery v.30 n.5 2015reponame:Brazilian Journal of Cardiovascular Surgery (Online)instname:Sociedade Brasileira de Cirurgia Cardiovascular (SBCCV)instacron:SBCCV10.5935/1678-9741.20150072info:eu-repo/semantics/openAccessGomes,Walter J.Leal,João CarlosJatene,Fabio BiscegliHossne Jr,Nelson A.Gabaldi,RenataFrazzato,Glaucia BassoAgreli,GuilhermeBraile,Domingo M.eng2016-01-05T00:00:00Zoai:scielo:S0102-76382015000500515Revistahttp://www.rbccv.org.br/https://old.scielo.br/oai/scielo-oai.php||rosangela.monteiro@incor.usp.br|| domingo@braile.com.br|| brandau@braile.com.br1678-97410102-7638opendoar:2016-01-05T00:00Brazilian Journal of Cardiovascular Surgery (Online) - Sociedade Brasileira de Cirurgia Cardiovascular (SBCCV)false |
dc.title.none.fl_str_mv |
Experimental Study and Early Clinical Application Of a Sutureless Aortic Bioprosthesis |
title |
Experimental Study and Early Clinical Application Of a Sutureless Aortic Bioprosthesis |
spellingShingle |
Experimental Study and Early Clinical Application Of a Sutureless Aortic Bioprosthesis Gomes,Walter J. Aortic Valve, Surgery Heart Valves, Surgery Aortic Valve Stenosis Bioprosthesis |
title_short |
Experimental Study and Early Clinical Application Of a Sutureless Aortic Bioprosthesis |
title_full |
Experimental Study and Early Clinical Application Of a Sutureless Aortic Bioprosthesis |
title_fullStr |
Experimental Study and Early Clinical Application Of a Sutureless Aortic Bioprosthesis |
title_full_unstemmed |
Experimental Study and Early Clinical Application Of a Sutureless Aortic Bioprosthesis |
title_sort |
Experimental Study and Early Clinical Application Of a Sutureless Aortic Bioprosthesis |
author |
Gomes,Walter J. |
author_facet |
Gomes,Walter J. Leal,João Carlos Jatene,Fabio Biscegli Hossne Jr,Nelson A. Gabaldi,Renata Frazzato,Glaucia Basso Agreli,Guilherme Braile,Domingo M. |
author_role |
author |
author2 |
Leal,João Carlos Jatene,Fabio Biscegli Hossne Jr,Nelson A. Gabaldi,Renata Frazzato,Glaucia Basso Agreli,Guilherme Braile,Domingo M. |
author2_role |
author author author author author author author |
dc.contributor.author.fl_str_mv |
Gomes,Walter J. Leal,João Carlos Jatene,Fabio Biscegli Hossne Jr,Nelson A. Gabaldi,Renata Frazzato,Glaucia Basso Agreli,Guilherme Braile,Domingo M. |
dc.subject.por.fl_str_mv |
Aortic Valve, Surgery Heart Valves, Surgery Aortic Valve Stenosis Bioprosthesis |
topic |
Aortic Valve, Surgery Heart Valves, Surgery Aortic Valve Stenosis Bioprosthesis |
description |
ABSTRACT INTRODUCTION: The conventional aortic valve replacement is the treatment of choice for symptomatic severe aortic stenosis. Transcatheter technique is a viable alternative with promising results for inoperable patients. Sutureless bioprostheses have shown benefits in high-risk patients, such as reduction of aortic clamping and cardiopulmonary bypass, decreasing risks and adverse effects. OBJECTIVE: The objective of this study was to experimentally evaluate the implantation of a novel balloon-expandable aortic valve with sutureless bioprosthesis in sheep and report the early clinical application. METHODS: The bioprosthesis is made of a metal frame and bovine pericardium leaflets, encapsulated in a catheter. The animals underwent left thoracotomy and the cardiopulmonary bypass was established. The sutureless bioprosthesis was deployed to the aortic valve, with 1/3 of the structure on the left ventricular face. Cardiopulmonary bypass, aortic clamping and deployment times were recorded. Echocardiograms were performed before, during and after the surgery. The bioprosthesis was initially implanted in an 85 year-old patient with aortic stenosis and high risk for conventional surgery, EuroSCORE 40 and multiple comorbidities. RESULTS: The sutureless bioprosthesis was rapidly deployed (50-170 seconds; average=95 seconds). The aortic clamping time ranged from 6-10 minutes, average of 7 minutes; the mean cardiopulmonary bypass time was 71 minutes. Bioprostheses were properly positioned without perivalvar leak. In the first operated patient the aortic clamp time was 39 minutes and the patient had good postoperative course. CONCLUSION: The deployment of the sutureless bioprosthesis was safe and effective, thereby representing a new alternative to conventional surgery or transcatheter in moderate- to high-risk patients with severe aortic stenosis. |
publishDate |
2015 |
dc.date.none.fl_str_mv |
2015-10-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-76382015000500515 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-76382015000500515 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.5935/1678-9741.20150072 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira de Cirurgia Cardiovascular |
publisher.none.fl_str_mv |
Sociedade Brasileira de Cirurgia Cardiovascular |
dc.source.none.fl_str_mv |
Brazilian Journal of Cardiovascular Surgery v.30 n.5 2015 reponame:Brazilian Journal of Cardiovascular Surgery (Online) instname:Sociedade Brasileira de Cirurgia Cardiovascular (SBCCV) instacron:SBCCV |
instname_str |
Sociedade Brasileira de Cirurgia Cardiovascular (SBCCV) |
instacron_str |
SBCCV |
institution |
SBCCV |
reponame_str |
Brazilian Journal of Cardiovascular Surgery (Online) |
collection |
Brazilian Journal of Cardiovascular Surgery (Online) |
repository.name.fl_str_mv |
Brazilian Journal of Cardiovascular Surgery (Online) - Sociedade Brasileira de Cirurgia Cardiovascular (SBCCV) |
repository.mail.fl_str_mv |
||rosangela.monteiro@incor.usp.br|| domingo@braile.com.br|| brandau@braile.com.br |
_version_ |
1752126599009927168 |