Are Standard Follow-Up Parameters Sufficient to Protect Neurocognitive Functions in Patients with Diabetes Mellitus who Underwent Coronary Artery Bypass Grafting?
Autor(a) principal: | |
---|---|
Data de Publicação: | 2020 |
Outros Autores: | |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Brazilian Journal of Cardiovascular Surgery (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-76382020000100075 |
Resumo: | Abstract Objective: We aimed to compare the effectiveness of cognitive function protection between the standard follow-up parameters and advanced neuromonitoring methods in diabetic patients who underwent coronary artery bypass grafting during cardiopulmonary bypass. Methods: Study design was prospective and observational. Patients were separated into two groups, treated only with standard follow-up parameters (Group 1) and followed up with the change of regional cerebral tissue oxygenation (rSO2) by near-infrared spectroscopy (Group 2). Neurocognitive functions were evaluated preoperatively and postoperatively before discharge in all patients using the Montreal Cognitive Assessment (MoCA) test. Results: Cognitive functions of Group 2 patients in the postoperative period were significantly higher than Group 1 patients (P=0.001). The mean postoperative MoCA score of patients was significantly lower than the mean preoperative MoCA score in Group 1 (24.8±2.2 vs. 23.6±2.6, P=0.02). However, mild cognitive dysfunction was significantly lower in Group 2, compared to Group 1 (P=0.02). Conclusion: In patients followed up with standard parameters, a significant decrease in cognitive function was observed in the early period. However, the use of advanced neuromonitoring methods can significantly prevent this decrease in cognitive functions. |
id |
SBCCV-1_f66854ca9162a80503bfa2df0bcfa80e |
---|---|
oai_identifier_str |
oai:scielo:S0102-76382020000100075 |
network_acronym_str |
SBCCV-1 |
network_name_str |
Brazilian Journal of Cardiovascular Surgery (Online) |
repository_id_str |
|
spelling |
Are Standard Follow-Up Parameters Sufficient to Protect Neurocognitive Functions in Patients with Diabetes Mellitus who Underwent Coronary Artery Bypass Grafting?Cardiopulmonary BypassCognitive DysfunctionSpectroscopyNear-InfraredCoronary Artery BypassDiabetes MellitusAbstract Objective: We aimed to compare the effectiveness of cognitive function protection between the standard follow-up parameters and advanced neuromonitoring methods in diabetic patients who underwent coronary artery bypass grafting during cardiopulmonary bypass. Methods: Study design was prospective and observational. Patients were separated into two groups, treated only with standard follow-up parameters (Group 1) and followed up with the change of regional cerebral tissue oxygenation (rSO2) by near-infrared spectroscopy (Group 2). Neurocognitive functions were evaluated preoperatively and postoperatively before discharge in all patients using the Montreal Cognitive Assessment (MoCA) test. Results: Cognitive functions of Group 2 patients in the postoperative period were significantly higher than Group 1 patients (P=0.001). The mean postoperative MoCA score of patients was significantly lower than the mean preoperative MoCA score in Group 1 (24.8±2.2 vs. 23.6±2.6, P=0.02). However, mild cognitive dysfunction was significantly lower in Group 2, compared to Group 1 (P=0.02). Conclusion: In patients followed up with standard parameters, a significant decrease in cognitive function was observed in the early period. However, the use of advanced neuromonitoring methods can significantly prevent this decrease in cognitive functions.Sociedade Brasileira de Cirurgia Cardiovascular2020-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-76382020000100075Brazilian Journal of Cardiovascular Surgery v.35 n.1 2020reponame:Brazilian Journal of Cardiovascular Surgery (Online)instname:Sociedade Brasileira de Cirurgia Cardiovascular (SBCCV)instacron:SBCCV10.21470/1678-9741-2019-0160info:eu-repo/semantics/openAccessSacli,HakanKara,Ibrahimeng2020-03-17T00:00:00Zoai:scielo:S0102-76382020000100075Revistahttp://www.rbccv.org.br/https://old.scielo.br/oai/scielo-oai.php||rosangela.monteiro@incor.usp.br|| domingo@braile.com.br|| brandau@braile.com.br1678-97410102-7638opendoar:2020-03-17T00:00Brazilian Journal of Cardiovascular Surgery (Online) - Sociedade Brasileira de Cirurgia Cardiovascular (SBCCV)false |
dc.title.none.fl_str_mv |
Are Standard Follow-Up Parameters Sufficient to Protect Neurocognitive Functions in Patients with Diabetes Mellitus who Underwent Coronary Artery Bypass Grafting? |
title |
Are Standard Follow-Up Parameters Sufficient to Protect Neurocognitive Functions in Patients with Diabetes Mellitus who Underwent Coronary Artery Bypass Grafting? |
spellingShingle |
Are Standard Follow-Up Parameters Sufficient to Protect Neurocognitive Functions in Patients with Diabetes Mellitus who Underwent Coronary Artery Bypass Grafting? Sacli,Hakan Cardiopulmonary Bypass Cognitive Dysfunction Spectroscopy Near-Infrared Coronary Artery Bypass Diabetes Mellitus |
title_short |
Are Standard Follow-Up Parameters Sufficient to Protect Neurocognitive Functions in Patients with Diabetes Mellitus who Underwent Coronary Artery Bypass Grafting? |
title_full |
Are Standard Follow-Up Parameters Sufficient to Protect Neurocognitive Functions in Patients with Diabetes Mellitus who Underwent Coronary Artery Bypass Grafting? |
title_fullStr |
Are Standard Follow-Up Parameters Sufficient to Protect Neurocognitive Functions in Patients with Diabetes Mellitus who Underwent Coronary Artery Bypass Grafting? |
title_full_unstemmed |
Are Standard Follow-Up Parameters Sufficient to Protect Neurocognitive Functions in Patients with Diabetes Mellitus who Underwent Coronary Artery Bypass Grafting? |
title_sort |
Are Standard Follow-Up Parameters Sufficient to Protect Neurocognitive Functions in Patients with Diabetes Mellitus who Underwent Coronary Artery Bypass Grafting? |
author |
Sacli,Hakan |
author_facet |
Sacli,Hakan Kara,Ibrahim |
author_role |
author |
author2 |
Kara,Ibrahim |
author2_role |
author |
dc.contributor.author.fl_str_mv |
Sacli,Hakan Kara,Ibrahim |
dc.subject.por.fl_str_mv |
Cardiopulmonary Bypass Cognitive Dysfunction Spectroscopy Near-Infrared Coronary Artery Bypass Diabetes Mellitus |
topic |
Cardiopulmonary Bypass Cognitive Dysfunction Spectroscopy Near-Infrared Coronary Artery Bypass Diabetes Mellitus |
description |
Abstract Objective: We aimed to compare the effectiveness of cognitive function protection between the standard follow-up parameters and advanced neuromonitoring methods in diabetic patients who underwent coronary artery bypass grafting during cardiopulmonary bypass. Methods: Study design was prospective and observational. Patients were separated into two groups, treated only with standard follow-up parameters (Group 1) and followed up with the change of regional cerebral tissue oxygenation (rSO2) by near-infrared spectroscopy (Group 2). Neurocognitive functions were evaluated preoperatively and postoperatively before discharge in all patients using the Montreal Cognitive Assessment (MoCA) test. Results: Cognitive functions of Group 2 patients in the postoperative period were significantly higher than Group 1 patients (P=0.001). The mean postoperative MoCA score of patients was significantly lower than the mean preoperative MoCA score in Group 1 (24.8±2.2 vs. 23.6±2.6, P=0.02). However, mild cognitive dysfunction was significantly lower in Group 2, compared to Group 1 (P=0.02). Conclusion: In patients followed up with standard parameters, a significant decrease in cognitive function was observed in the early period. However, the use of advanced neuromonitoring methods can significantly prevent this decrease in cognitive functions. |
publishDate |
2020 |
dc.date.none.fl_str_mv |
2020-01-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-76382020000100075 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-76382020000100075 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.21470/1678-9741-2019-0160 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira de Cirurgia Cardiovascular |
publisher.none.fl_str_mv |
Sociedade Brasileira de Cirurgia Cardiovascular |
dc.source.none.fl_str_mv |
Brazilian Journal of Cardiovascular Surgery v.35 n.1 2020 reponame:Brazilian Journal of Cardiovascular Surgery (Online) instname:Sociedade Brasileira de Cirurgia Cardiovascular (SBCCV) instacron:SBCCV |
instname_str |
Sociedade Brasileira de Cirurgia Cardiovascular (SBCCV) |
instacron_str |
SBCCV |
institution |
SBCCV |
reponame_str |
Brazilian Journal of Cardiovascular Surgery (Online) |
collection |
Brazilian Journal of Cardiovascular Surgery (Online) |
repository.name.fl_str_mv |
Brazilian Journal of Cardiovascular Surgery (Online) - Sociedade Brasileira de Cirurgia Cardiovascular (SBCCV) |
repository.mail.fl_str_mv |
||rosangela.monteiro@incor.usp.br|| domingo@braile.com.br|| brandau@braile.com.br |
_version_ |
1752126601144827904 |