APPLICABILITY OF THE COBB ANGLE MEASUREMENT IN IDIOPATHIC SCOLIOSIS USING SCANNED IMAGING

Detalhes bibliográficos
Autor(a) principal: ZARDO,ERASMO DE ABREU
Data de Publicação: 2017
Outros Autores: ZIEGLER,MARCUS SOFIA, SERDEIRA,AFRANE, SEVERO,CARLOS MARCELO DONAZAR, FRAST,RODRIGO VALENTE, RECH,PAULO RENATO, TOFFOLO,LAURO, SCALCO,RENATA SICILIANI, SCHWANKE,CARLA HELENA AUGUSTIN
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Coluna/Columna
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1808-18512017000100022
Resumo: ABSTRACT Objectives: To compare the measurement of the Cobb angle on printed radiographs and on scanned radiographs viewed through the software "PixViewer". Methods: Preoperative radiographs of 23 patients were evaluated on printed films and through the software "PixViewer". The same evaluator, a spine surgeon, chose the proximal and distal limiting vertebrae of the main curve on printed radiographs, without identification of patients, and measured the Cobb angle based on these parameters. The same parameters and measurements were applied to scanned radiographs. The measurements were compared, as well as the choice of limiting vertebrae. Results: The average variation of the Cobb angle between methods was 1.48 ± 1.73°. The intraclass correlation coefficient (ICC) was 0.99, demonstrating excellent reproducibility. Conclusion: The Cobb method can be used to evaluate scoliosis through the "PixViewer" tool with the same reliability as the classic method on printed radiographs.
id SBCO-1_38e95008c87e1e6b0248e77ddaf44988
oai_identifier_str oai:scielo:S1808-18512017000100022
network_acronym_str SBCO-1
network_name_str Coluna/Columna
repository_id_str
spelling APPLICABILITY OF THE COBB ANGLE MEASUREMENT IN IDIOPATHIC SCOLIOSIS USING SCANNED IMAGINGScoliosisSpinal diseasesSpinal curvaturesRadiographic image enhancement.ABSTRACT Objectives: To compare the measurement of the Cobb angle on printed radiographs and on scanned radiographs viewed through the software "PixViewer". Methods: Preoperative radiographs of 23 patients were evaluated on printed films and through the software "PixViewer". The same evaluator, a spine surgeon, chose the proximal and distal limiting vertebrae of the main curve on printed radiographs, without identification of patients, and measured the Cobb angle based on these parameters. The same parameters and measurements were applied to scanned radiographs. The measurements were compared, as well as the choice of limiting vertebrae. Results: The average variation of the Cobb angle between methods was 1.48 ± 1.73°. The intraclass correlation coefficient (ICC) was 0.99, demonstrating excellent reproducibility. Conclusion: The Cobb method can be used to evaluate scoliosis through the "PixViewer" tool with the same reliability as the classic method on printed radiographs.Sociedade Brasileira de Coluna2017-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1808-18512017000100022Coluna/Columna v.16 n.1 2017reponame:Coluna/Columnainstname:Sociedade Brasileira de Coluna (SBCO)instacron:SBCO10.1590/s1808-185120171601153058info:eu-repo/semantics/openAccessZARDO,ERASMO DE ABREUZIEGLER,MARCUS SOFIASERDEIRA,AFRANESEVERO,CARLOS MARCELO DONAZARFRAST,RODRIGO VALENTERECH,PAULO RENATOTOFFOLO,LAUROSCALCO,RENATA SICILIANISCHWANKE,CARLA HELENA AUGUSTINeng2017-04-11T00:00:00Zoai:scielo:S1808-18512017000100022Revistahttps://www.revistacoluna.org/ONGhttps://old.scielo.br/oai/scielo-oai.phpcoluna.columna@uol.com.br||revistacoluna@uol.com.br2177-014X1808-1851opendoar:2017-04-11T00:00Coluna/Columna - Sociedade Brasileira de Coluna (SBCO)false
dc.title.none.fl_str_mv APPLICABILITY OF THE COBB ANGLE MEASUREMENT IN IDIOPATHIC SCOLIOSIS USING SCANNED IMAGING
title APPLICABILITY OF THE COBB ANGLE MEASUREMENT IN IDIOPATHIC SCOLIOSIS USING SCANNED IMAGING
spellingShingle APPLICABILITY OF THE COBB ANGLE MEASUREMENT IN IDIOPATHIC SCOLIOSIS USING SCANNED IMAGING
ZARDO,ERASMO DE ABREU
Scoliosis
Spinal diseases
Spinal curvatures
Radiographic image enhancement.
title_short APPLICABILITY OF THE COBB ANGLE MEASUREMENT IN IDIOPATHIC SCOLIOSIS USING SCANNED IMAGING
title_full APPLICABILITY OF THE COBB ANGLE MEASUREMENT IN IDIOPATHIC SCOLIOSIS USING SCANNED IMAGING
title_fullStr APPLICABILITY OF THE COBB ANGLE MEASUREMENT IN IDIOPATHIC SCOLIOSIS USING SCANNED IMAGING
title_full_unstemmed APPLICABILITY OF THE COBB ANGLE MEASUREMENT IN IDIOPATHIC SCOLIOSIS USING SCANNED IMAGING
title_sort APPLICABILITY OF THE COBB ANGLE MEASUREMENT IN IDIOPATHIC SCOLIOSIS USING SCANNED IMAGING
author ZARDO,ERASMO DE ABREU
author_facet ZARDO,ERASMO DE ABREU
ZIEGLER,MARCUS SOFIA
SERDEIRA,AFRANE
SEVERO,CARLOS MARCELO DONAZAR
FRAST,RODRIGO VALENTE
RECH,PAULO RENATO
TOFFOLO,LAURO
SCALCO,RENATA SICILIANI
SCHWANKE,CARLA HELENA AUGUSTIN
author_role author
author2 ZIEGLER,MARCUS SOFIA
SERDEIRA,AFRANE
SEVERO,CARLOS MARCELO DONAZAR
FRAST,RODRIGO VALENTE
RECH,PAULO RENATO
TOFFOLO,LAURO
SCALCO,RENATA SICILIANI
SCHWANKE,CARLA HELENA AUGUSTIN
author2_role author
author
author
author
author
author
author
author
dc.contributor.author.fl_str_mv ZARDO,ERASMO DE ABREU
ZIEGLER,MARCUS SOFIA
SERDEIRA,AFRANE
SEVERO,CARLOS MARCELO DONAZAR
FRAST,RODRIGO VALENTE
RECH,PAULO RENATO
TOFFOLO,LAURO
SCALCO,RENATA SICILIANI
SCHWANKE,CARLA HELENA AUGUSTIN
dc.subject.por.fl_str_mv Scoliosis
Spinal diseases
Spinal curvatures
Radiographic image enhancement.
topic Scoliosis
Spinal diseases
Spinal curvatures
Radiographic image enhancement.
description ABSTRACT Objectives: To compare the measurement of the Cobb angle on printed radiographs and on scanned radiographs viewed through the software "PixViewer". Methods: Preoperative radiographs of 23 patients were evaluated on printed films and through the software "PixViewer". The same evaluator, a spine surgeon, chose the proximal and distal limiting vertebrae of the main curve on printed radiographs, without identification of patients, and measured the Cobb angle based on these parameters. The same parameters and measurements were applied to scanned radiographs. The measurements were compared, as well as the choice of limiting vertebrae. Results: The average variation of the Cobb angle between methods was 1.48 ± 1.73°. The intraclass correlation coefficient (ICC) was 0.99, demonstrating excellent reproducibility. Conclusion: The Cobb method can be used to evaluate scoliosis through the "PixViewer" tool with the same reliability as the classic method on printed radiographs.
publishDate 2017
dc.date.none.fl_str_mv 2017-01-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1808-18512017000100022
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1808-18512017000100022
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/s1808-185120171601153058
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Coluna
publisher.none.fl_str_mv Sociedade Brasileira de Coluna
dc.source.none.fl_str_mv Coluna/Columna v.16 n.1 2017
reponame:Coluna/Columna
instname:Sociedade Brasileira de Coluna (SBCO)
instacron:SBCO
instname_str Sociedade Brasileira de Coluna (SBCO)
instacron_str SBCO
institution SBCO
reponame_str Coluna/Columna
collection Coluna/Columna
repository.name.fl_str_mv Coluna/Columna - Sociedade Brasileira de Coluna (SBCO)
repository.mail.fl_str_mv coluna.columna@uol.com.br||revistacoluna@uol.com.br
_version_ 1752126615496687616