IMAGE-GUIDED SURGERY IN THE SPINE: NEURONAVIGATION VS. FLUOROSCOPY

Detalhes bibliográficos
Autor(a) principal: Guedes,Vinícius de Paula
Data de Publicação: 2015
Outros Autores: Manffra,Elisangela Ferrretti, Aguiar,Luiz Roberto
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Coluna/Columna
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1808-18512015000300181
Resumo: Objectives:To evaluate the accuracy and the operative complications of implanting pedicle screws in the thoracic and lumbar spine, using computer-assisted surgery compared to the implantation technique using fluoroscopy.Methods:A retrospective study was conducted at the Hospital Universitário Cajuru PUC-PR from January 2000 to January 2009. Two groups of patients undergoing implant pedicle screws were analyzed (n=80). Group I received implant pedicle screws through fluoroscopy technique and group II, through neuronavigation technique. The accuracy of positioning of pedicle screws was evaluated using rating scales.Results:The accuracy was higher in group II, where 77.5% of the screws were correctly positioned, whereas there were only 28.5% in group I (p=0.001). There was a reduction of 95% (CI: 80-97%) in the risk of screws misplacement in group II. The average operation time was 312.2±78.1 minutes in group I and 270.3±41.4 in group II (p=0.004). Blood transfusion was needed in 28 patients in group I and 10 patients in group II (p=0.005), resulting in 64% risk reduction of blood transfusion in group II. Eight patients in group I underwent revision surgery whereas only one patient in the group II, that is, 75% of surgical revision risk reduction.Conclusion:The implantation technique of pedicle screws using neuronavigation is a more accurate method and has less operative complications compared with the technique that uses fluoroscopy.
id SBCO-1_d6977f3ff9dce3dd946c27c48cfbc89d
oai_identifier_str oai:scielo:S1808-18512015000300181
network_acronym_str SBCO-1
network_name_str Coluna/Columna
repository_id_str
spelling IMAGE-GUIDED SURGERY IN THE SPINE: NEURONAVIGATION VS. FLUOROSCOPYSpine/surgerySurgery, computer-assistedNeuronavigationFluoroscopyObjectives:To evaluate the accuracy and the operative complications of implanting pedicle screws in the thoracic and lumbar spine, using computer-assisted surgery compared to the implantation technique using fluoroscopy.Methods:A retrospective study was conducted at the Hospital Universitário Cajuru PUC-PR from January 2000 to January 2009. Two groups of patients undergoing implant pedicle screws were analyzed (n=80). Group I received implant pedicle screws through fluoroscopy technique and group II, through neuronavigation technique. The accuracy of positioning of pedicle screws was evaluated using rating scales.Results:The accuracy was higher in group II, where 77.5% of the screws were correctly positioned, whereas there were only 28.5% in group I (p=0.001). There was a reduction of 95% (CI: 80-97%) in the risk of screws misplacement in group II. The average operation time was 312.2±78.1 minutes in group I and 270.3±41.4 in group II (p=0.004). Blood transfusion was needed in 28 patients in group I and 10 patients in group II (p=0.005), resulting in 64% risk reduction of blood transfusion in group II. Eight patients in group I underwent revision surgery whereas only one patient in the group II, that is, 75% of surgical revision risk reduction.Conclusion:The implantation technique of pedicle screws using neuronavigation is a more accurate method and has less operative complications compared with the technique that uses fluoroscopy.Sociedade Brasileira de Coluna2015-09-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1808-18512015000300181Coluna/Columna v.14 n.3 2015reponame:Coluna/Columnainstname:Sociedade Brasileira de Coluna (SBCO)instacron:SBCO10.1590/S1808-185120151403122410info:eu-repo/semantics/openAccessGuedes,Vinícius de PaulaManffra,Elisangela FerrrettiAguiar,Luiz Robertoeng2015-10-23T00:00:00Zoai:scielo:S1808-18512015000300181Revistahttps://www.revistacoluna.org/ONGhttps://old.scielo.br/oai/scielo-oai.phpcoluna.columna@uol.com.br||revistacoluna@uol.com.br2177-014X1808-1851opendoar:2015-10-23T00:00Coluna/Columna - Sociedade Brasileira de Coluna (SBCO)false
dc.title.none.fl_str_mv IMAGE-GUIDED SURGERY IN THE SPINE: NEURONAVIGATION VS. FLUOROSCOPY
title IMAGE-GUIDED SURGERY IN THE SPINE: NEURONAVIGATION VS. FLUOROSCOPY
spellingShingle IMAGE-GUIDED SURGERY IN THE SPINE: NEURONAVIGATION VS. FLUOROSCOPY
Guedes,Vinícius de Paula
Spine/surgery
Surgery, computer-assisted
Neuronavigation
Fluoroscopy
title_short IMAGE-GUIDED SURGERY IN THE SPINE: NEURONAVIGATION VS. FLUOROSCOPY
title_full IMAGE-GUIDED SURGERY IN THE SPINE: NEURONAVIGATION VS. FLUOROSCOPY
title_fullStr IMAGE-GUIDED SURGERY IN THE SPINE: NEURONAVIGATION VS. FLUOROSCOPY
title_full_unstemmed IMAGE-GUIDED SURGERY IN THE SPINE: NEURONAVIGATION VS. FLUOROSCOPY
title_sort IMAGE-GUIDED SURGERY IN THE SPINE: NEURONAVIGATION VS. FLUOROSCOPY
author Guedes,Vinícius de Paula
author_facet Guedes,Vinícius de Paula
Manffra,Elisangela Ferrretti
Aguiar,Luiz Roberto
author_role author
author2 Manffra,Elisangela Ferrretti
Aguiar,Luiz Roberto
author2_role author
author
dc.contributor.author.fl_str_mv Guedes,Vinícius de Paula
Manffra,Elisangela Ferrretti
Aguiar,Luiz Roberto
dc.subject.por.fl_str_mv Spine/surgery
Surgery, computer-assisted
Neuronavigation
Fluoroscopy
topic Spine/surgery
Surgery, computer-assisted
Neuronavigation
Fluoroscopy
description Objectives:To evaluate the accuracy and the operative complications of implanting pedicle screws in the thoracic and lumbar spine, using computer-assisted surgery compared to the implantation technique using fluoroscopy.Methods:A retrospective study was conducted at the Hospital Universitário Cajuru PUC-PR from January 2000 to January 2009. Two groups of patients undergoing implant pedicle screws were analyzed (n=80). Group I received implant pedicle screws through fluoroscopy technique and group II, through neuronavigation technique. The accuracy of positioning of pedicle screws was evaluated using rating scales.Results:The accuracy was higher in group II, where 77.5% of the screws were correctly positioned, whereas there were only 28.5% in group I (p=0.001). There was a reduction of 95% (CI: 80-97%) in the risk of screws misplacement in group II. The average operation time was 312.2±78.1 minutes in group I and 270.3±41.4 in group II (p=0.004). Blood transfusion was needed in 28 patients in group I and 10 patients in group II (p=0.005), resulting in 64% risk reduction of blood transfusion in group II. Eight patients in group I underwent revision surgery whereas only one patient in the group II, that is, 75% of surgical revision risk reduction.Conclusion:The implantation technique of pedicle screws using neuronavigation is a more accurate method and has less operative complications compared with the technique that uses fluoroscopy.
publishDate 2015
dc.date.none.fl_str_mv 2015-09-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1808-18512015000300181
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1808-18512015000300181
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S1808-185120151403122410
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Coluna
publisher.none.fl_str_mv Sociedade Brasileira de Coluna
dc.source.none.fl_str_mv Coluna/Columna v.14 n.3 2015
reponame:Coluna/Columna
instname:Sociedade Brasileira de Coluna (SBCO)
instacron:SBCO
instname_str Sociedade Brasileira de Coluna (SBCO)
instacron_str SBCO
institution SBCO
reponame_str Coluna/Columna
collection Coluna/Columna
repository.name.fl_str_mv Coluna/Columna - Sociedade Brasileira de Coluna (SBCO)
repository.mail.fl_str_mv coluna.columna@uol.com.br||revistacoluna@uol.com.br
_version_ 1752126615077257216