COMPARISON OF EXPOSURE TO RADIATION DURING PERCUTANEOUS TRANSPEDICULAR PROCEDURES, USING THREE FLUOROSCOPIC TECHNIQUES
Autor(a) principal: | |
---|---|
Data de Publicação: | 2017 |
Outros Autores: | , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Coluna/Columna |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1808-18512017000200141 |
Resumo: | ABSTRACT Objective: To compare radiation exposure to the surgeon, patient and radiation technician during percutaneous access of the vertebral pedicle, using three different fluoroscopic imaging set up. Methods: Percutaneous access in pedicle T9-L5 of nine adult male cadavers using three different fluoroscopic set ups: standard C-arm, C-arm with L-arm, and the biplanar technique. The radiation dose exposure of the surgeon, radiation technician, and cadaver were measured using dosimeter in each procedure and in real time. Results: The radiation dose absorbed by the surgeon was higher when using the standard C-arm fluoroscopic technique than when using the C-arm with L-arm or the biplanar technique. Conclusions: The use of the C-arm with L-arm, or the biplanar fluoroscopic technique, for percutaneous access to the vertebral pedicle, reduces the radiation exposure of the surgeon compared to the standard C-arm fluoroscopic technique. |
id |
SBCO-1_eb7e318f71a1682b2119f6682065a03b |
---|---|
oai_identifier_str |
oai:scielo:S1808-18512017000200141 |
network_acronym_str |
SBCO-1 |
network_name_str |
Coluna/Columna |
repository_id_str |
|
spelling |
COMPARISON OF EXPOSURE TO RADIATION DURING PERCUTANEOUS TRANSPEDICULAR PROCEDURES, USING THREE FLUOROSCOPIC TECHNIQUESLumbar vertebraeThoracic vertebraeFluoroscopyRadiation dosageMinimally invasive surgical procedures.ABSTRACT Objective: To compare radiation exposure to the surgeon, patient and radiation technician during percutaneous access of the vertebral pedicle, using three different fluoroscopic imaging set up. Methods: Percutaneous access in pedicle T9-L5 of nine adult male cadavers using three different fluoroscopic set ups: standard C-arm, C-arm with L-arm, and the biplanar technique. The radiation dose exposure of the surgeon, radiation technician, and cadaver were measured using dosimeter in each procedure and in real time. Results: The radiation dose absorbed by the surgeon was higher when using the standard C-arm fluoroscopic technique than when using the C-arm with L-arm or the biplanar technique. Conclusions: The use of the C-arm with L-arm, or the biplanar fluoroscopic technique, for percutaneous access to the vertebral pedicle, reduces the radiation exposure of the surgeon compared to the standard C-arm fluoroscopic technique.Sociedade Brasileira de Coluna2017-04-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1808-18512017000200141Coluna/Columna v.16 n.2 2017reponame:Coluna/Columnainstname:Sociedade Brasileira de Coluna (SBCO)instacron:SBCO10.1590/s1808-185120171602178378info:eu-repo/semantics/openAccessNascimento,AndersonHerrero,Carlos Fernando Pereira da SilvaDefino,Helton Luiz AparecidoViana,Marina Silva MagalhãesAraújo,João deFernandes,Ronaldo Lavôreng2017-06-21T00:00:00Zoai:scielo:S1808-18512017000200141Revistahttps://www.revistacoluna.org/ONGhttps://old.scielo.br/oai/scielo-oai.phpcoluna.columna@uol.com.br||revistacoluna@uol.com.br2177-014X1808-1851opendoar:2017-06-21T00:00Coluna/Columna - Sociedade Brasileira de Coluna (SBCO)false |
dc.title.none.fl_str_mv |
COMPARISON OF EXPOSURE TO RADIATION DURING PERCUTANEOUS TRANSPEDICULAR PROCEDURES, USING THREE FLUOROSCOPIC TECHNIQUES |
title |
COMPARISON OF EXPOSURE TO RADIATION DURING PERCUTANEOUS TRANSPEDICULAR PROCEDURES, USING THREE FLUOROSCOPIC TECHNIQUES |
spellingShingle |
COMPARISON OF EXPOSURE TO RADIATION DURING PERCUTANEOUS TRANSPEDICULAR PROCEDURES, USING THREE FLUOROSCOPIC TECHNIQUES Nascimento,Anderson Lumbar vertebrae Thoracic vertebrae Fluoroscopy Radiation dosage Minimally invasive surgical procedures. |
title_short |
COMPARISON OF EXPOSURE TO RADIATION DURING PERCUTANEOUS TRANSPEDICULAR PROCEDURES, USING THREE FLUOROSCOPIC TECHNIQUES |
title_full |
COMPARISON OF EXPOSURE TO RADIATION DURING PERCUTANEOUS TRANSPEDICULAR PROCEDURES, USING THREE FLUOROSCOPIC TECHNIQUES |
title_fullStr |
COMPARISON OF EXPOSURE TO RADIATION DURING PERCUTANEOUS TRANSPEDICULAR PROCEDURES, USING THREE FLUOROSCOPIC TECHNIQUES |
title_full_unstemmed |
COMPARISON OF EXPOSURE TO RADIATION DURING PERCUTANEOUS TRANSPEDICULAR PROCEDURES, USING THREE FLUOROSCOPIC TECHNIQUES |
title_sort |
COMPARISON OF EXPOSURE TO RADIATION DURING PERCUTANEOUS TRANSPEDICULAR PROCEDURES, USING THREE FLUOROSCOPIC TECHNIQUES |
author |
Nascimento,Anderson |
author_facet |
Nascimento,Anderson Herrero,Carlos Fernando Pereira da Silva Defino,Helton Luiz Aparecido Viana,Marina Silva Magalhães Araújo,João de Fernandes,Ronaldo Lavôr |
author_role |
author |
author2 |
Herrero,Carlos Fernando Pereira da Silva Defino,Helton Luiz Aparecido Viana,Marina Silva Magalhães Araújo,João de Fernandes,Ronaldo Lavôr |
author2_role |
author author author author author |
dc.contributor.author.fl_str_mv |
Nascimento,Anderson Herrero,Carlos Fernando Pereira da Silva Defino,Helton Luiz Aparecido Viana,Marina Silva Magalhães Araújo,João de Fernandes,Ronaldo Lavôr |
dc.subject.por.fl_str_mv |
Lumbar vertebrae Thoracic vertebrae Fluoroscopy Radiation dosage Minimally invasive surgical procedures. |
topic |
Lumbar vertebrae Thoracic vertebrae Fluoroscopy Radiation dosage Minimally invasive surgical procedures. |
description |
ABSTRACT Objective: To compare radiation exposure to the surgeon, patient and radiation technician during percutaneous access of the vertebral pedicle, using three different fluoroscopic imaging set up. Methods: Percutaneous access in pedicle T9-L5 of nine adult male cadavers using three different fluoroscopic set ups: standard C-arm, C-arm with L-arm, and the biplanar technique. The radiation dose exposure of the surgeon, radiation technician, and cadaver were measured using dosimeter in each procedure and in real time. Results: The radiation dose absorbed by the surgeon was higher when using the standard C-arm fluoroscopic technique than when using the C-arm with L-arm or the biplanar technique. Conclusions: The use of the C-arm with L-arm, or the biplanar fluoroscopic technique, for percutaneous access to the vertebral pedicle, reduces the radiation exposure of the surgeon compared to the standard C-arm fluoroscopic technique. |
publishDate |
2017 |
dc.date.none.fl_str_mv |
2017-04-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1808-18512017000200141 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1808-18512017000200141 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/s1808-185120171602178378 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira de Coluna |
publisher.none.fl_str_mv |
Sociedade Brasileira de Coluna |
dc.source.none.fl_str_mv |
Coluna/Columna v.16 n.2 2017 reponame:Coluna/Columna instname:Sociedade Brasileira de Coluna (SBCO) instacron:SBCO |
instname_str |
Sociedade Brasileira de Coluna (SBCO) |
instacron_str |
SBCO |
institution |
SBCO |
reponame_str |
Coluna/Columna |
collection |
Coluna/Columna |
repository.name.fl_str_mv |
Coluna/Columna - Sociedade Brasileira de Coluna (SBCO) |
repository.mail.fl_str_mv |
coluna.columna@uol.com.br||revistacoluna@uol.com.br |
_version_ |
1752126615540727808 |