Resumo: | A biosensor was developed for spectrophotometric determination of glucose concentrations in real samples of orange juice energetic drinks, and sport drinks. The biosensor consisted of glucose oxidase (GOD) and horseradish peroxidase (HRP) immobilized onto polyaniline activated with glutaraldehyde (PANIG). Immobilization parameters were optimized for GOD, and maximum immobilization yield was 16% when 5.0 mg of PANIG and 8.9 U prepared in 0.1 mol.L-1 sodium phosphate buffer (pH 7.0) reacted for 60 minutes at 4 °C with gentle stirring. The linear operational range for glucose determination using optimized operational parameters was between 0.05 and 6.0 mg.mL-1 with a very good reproducibility of response. The results obtained in the biosensor were compared with those obtained using free enzymes (commercial kits) and then validated through statistical analysis using the Tukey test (95% confidence interval). |
id |
SBCTA-1_0b34820eea54fb89af3c3ae0d9bc3dd1 |
---|---|
oai_identifier_str |
oai:scielo:S0101-20612012000100010 |
network_acronym_str |
SBCTA-1 |
network_name_str |
Food Science and Technology (Campinas) |
repository_id_str |
|
spelling |
Biosensor for determination of glucose in real samples of beveragesbiosensorglucoseglucose oxidaseimmobilizationpolyanilineA biosensor was developed for spectrophotometric determination of glucose concentrations in real samples of orange juice energetic drinks, and sport drinks. The biosensor consisted of glucose oxidase (GOD) and horseradish peroxidase (HRP) immobilized onto polyaniline activated with glutaraldehyde (PANIG). Immobilization parameters were optimized for GOD, and maximum immobilization yield was 16% when 5.0 mg of PANIG and 8.9 U prepared in 0.1 mol.L-1 sodium phosphate buffer (pH 7.0) reacted for 60 minutes at 4 °C with gentle stirring. The linear operational range for glucose determination using optimized operational parameters was between 0.05 and 6.0 mg.mL-1 with a very good reproducibility of response. The results obtained in the biosensor were compared with those obtained using free enzymes (commercial kits) and then validated through statistical analysis using the Tukey test (95% confidence interval).Sociedade Brasileira de Ciência e Tecnologia de Alimentos2012-03-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0101-20612012000100010Food Science and Technology v.32 n.1 2012reponame:Food Science and Technology (Campinas)instname:Sociedade Brasileira de Ciência e Tecnologia de Alimentos (SBCTA)instacron:SBCTA10.1590/S0101-20612012005000003info:eu-repo/semantics/openAccessLopes,Flavio MarquesBatista,Karla de AleluiaBatista,Gustavo Luiz AleluiaFernandes,Kátia Fláviaeng2012-05-18T00:00:00Zoai:scielo:S0101-20612012000100010Revistahttp://www.scielo.br/ctaONGhttps://old.scielo.br/oai/scielo-oai.php||revista@sbcta.org.br1678-457X0101-2061opendoar:2012-05-18T00:00Food Science and Technology (Campinas) - Sociedade Brasileira de Ciência e Tecnologia de Alimentos (SBCTA)false |
dc.title.none.fl_str_mv |
Biosensor for determination of glucose in real samples of beverages |
title |
Biosensor for determination of glucose in real samples of beverages |
spellingShingle |
Biosensor for determination of glucose in real samples of beverages Lopes,Flavio Marques biosensor glucose glucose oxidase immobilization polyaniline |
title_short |
Biosensor for determination of glucose in real samples of beverages |
title_full |
Biosensor for determination of glucose in real samples of beverages |
title_fullStr |
Biosensor for determination of glucose in real samples of beverages |
title_full_unstemmed |
Biosensor for determination of glucose in real samples of beverages |
title_sort |
Biosensor for determination of glucose in real samples of beverages |
author |
Lopes,Flavio Marques |
author_facet |
Lopes,Flavio Marques Batista,Karla de Aleluia Batista,Gustavo Luiz Aleluia Fernandes,Kátia Flávia |
author_role |
author |
author2 |
Batista,Karla de Aleluia Batista,Gustavo Luiz Aleluia Fernandes,Kátia Flávia |
author2_role |
author author author |
dc.contributor.author.fl_str_mv |
Lopes,Flavio Marques Batista,Karla de Aleluia Batista,Gustavo Luiz Aleluia Fernandes,Kátia Flávia |
dc.subject.por.fl_str_mv |
biosensor glucose glucose oxidase immobilization polyaniline |
topic |
biosensor glucose glucose oxidase immobilization polyaniline |
description |
A biosensor was developed for spectrophotometric determination of glucose concentrations in real samples of orange juice energetic drinks, and sport drinks. The biosensor consisted of glucose oxidase (GOD) and horseradish peroxidase (HRP) immobilized onto polyaniline activated with glutaraldehyde (PANIG). Immobilization parameters were optimized for GOD, and maximum immobilization yield was 16% when 5.0 mg of PANIG and 8.9 U prepared in 0.1 mol.L-1 sodium phosphate buffer (pH 7.0) reacted for 60 minutes at 4 °C with gentle stirring. The linear operational range for glucose determination using optimized operational parameters was between 0.05 and 6.0 mg.mL-1 with a very good reproducibility of response. The results obtained in the biosensor were compared with those obtained using free enzymes (commercial kits) and then validated through statistical analysis using the Tukey test (95% confidence interval). |
publishDate |
2012 |
dc.date.none.fl_str_mv |
2012-03-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0101-20612012000100010 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0101-20612012000100010 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/S0101-20612012005000003 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira de Ciência e Tecnologia de Alimentos |
publisher.none.fl_str_mv |
Sociedade Brasileira de Ciência e Tecnologia de Alimentos |
dc.source.none.fl_str_mv |
Food Science and Technology v.32 n.1 2012 reponame:Food Science and Technology (Campinas) instname:Sociedade Brasileira de Ciência e Tecnologia de Alimentos (SBCTA) instacron:SBCTA |
instname_str |
Sociedade Brasileira de Ciência e Tecnologia de Alimentos (SBCTA) |
instacron_str |
SBCTA |
institution |
SBCTA |
reponame_str |
Food Science and Technology (Campinas) |
collection |
Food Science and Technology (Campinas) |
repository.name.fl_str_mv |
Food Science and Technology (Campinas) - Sociedade Brasileira de Ciência e Tecnologia de Alimentos (SBCTA) |
repository.mail.fl_str_mv |
||revista@sbcta.org.br |
_version_ |
1752126317299499008 |