A method to determine volatile contaminants in polyethylene terephthalate (PET) packages by HDC-GC-FID and its application to post-consumer materials
Autor(a) principal: | |
---|---|
Data de Publicação: | 2010 |
Outros Autores: | , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Food Science and Technology (Campinas) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0101-20612010000400033 |
Resumo: | A simple and low cost method to determine volatile contaminants in post-consumer recycled PET flakes was developed and validated by Headspace Dynamic Concentration and Gas Chromatography-Flame Ionization Detection (HDC-GC-FID). The analytical parameters evaluated by using surrogates include: correlation coefficient, detection limit, quantification limit, accuracy, intra-assay precision, and inter-assay precision. In order to compare the efficiency of the proposed method to recognized automated techniques, post-consumer PET packaging samples collected in Brazil were used. GC-MS was used to confirm the identity of the substances identified in the PET packaging. Some of the identified contaminants were estimated in the post-consumer material at concentrations higher than 220 ng.g-1. The findings in this work corroborate data available in the scientific literature pointing out the suitability of the proposed analytical method. |
id |
SBCTA-1_9fecf00ec00e272f8adac0624d2c2627 |
---|---|
oai_identifier_str |
oai:scielo:S0101-20612010000400033 |
network_acronym_str |
SBCTA-1 |
network_name_str |
Food Science and Technology (Campinas) |
repository_id_str |
|
spelling |
A method to determine volatile contaminants in polyethylene terephthalate (PET) packages by HDC-GC-FID and its application to post-consumer materialsextractionvalidationgas chromatographyPET packagingA simple and low cost method to determine volatile contaminants in post-consumer recycled PET flakes was developed and validated by Headspace Dynamic Concentration and Gas Chromatography-Flame Ionization Detection (HDC-GC-FID). The analytical parameters evaluated by using surrogates include: correlation coefficient, detection limit, quantification limit, accuracy, intra-assay precision, and inter-assay precision. In order to compare the efficiency of the proposed method to recognized automated techniques, post-consumer PET packaging samples collected in Brazil were used. GC-MS was used to confirm the identity of the substances identified in the PET packaging. Some of the identified contaminants were estimated in the post-consumer material at concentrations higher than 220 ng.g-1. The findings in this work corroborate data available in the scientific literature pointing out the suitability of the proposed analytical method.Sociedade Brasileira de Ciência e Tecnologia de Alimentos2010-12-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0101-20612010000400033Food Science and Technology v.30 n.4 2010reponame:Food Science and Technology (Campinas)instname:Sociedade Brasileira de Ciência e Tecnologia de Alimentos (SBCTA)instacron:SBCTA10.1590/S0101-20612010000400033info:eu-repo/semantics/openAccessFabris,SamantaFreire,Maria Teresa de AlvarengaWagner,RogerReyes,Felix Guillermoeng2011-01-26T00:00:00Zoai:scielo:S0101-20612010000400033Revistahttp://www.scielo.br/ctaONGhttps://old.scielo.br/oai/scielo-oai.php||revista@sbcta.org.br1678-457X0101-2061opendoar:2011-01-26T00:00Food Science and Technology (Campinas) - Sociedade Brasileira de Ciência e Tecnologia de Alimentos (SBCTA)false |
dc.title.none.fl_str_mv |
A method to determine volatile contaminants in polyethylene terephthalate (PET) packages by HDC-GC-FID and its application to post-consumer materials |
title |
A method to determine volatile contaminants in polyethylene terephthalate (PET) packages by HDC-GC-FID and its application to post-consumer materials |
spellingShingle |
A method to determine volatile contaminants in polyethylene terephthalate (PET) packages by HDC-GC-FID and its application to post-consumer materials Fabris,Samanta extraction validation gas chromatography PET packaging |
title_short |
A method to determine volatile contaminants in polyethylene terephthalate (PET) packages by HDC-GC-FID and its application to post-consumer materials |
title_full |
A method to determine volatile contaminants in polyethylene terephthalate (PET) packages by HDC-GC-FID and its application to post-consumer materials |
title_fullStr |
A method to determine volatile contaminants in polyethylene terephthalate (PET) packages by HDC-GC-FID and its application to post-consumer materials |
title_full_unstemmed |
A method to determine volatile contaminants in polyethylene terephthalate (PET) packages by HDC-GC-FID and its application to post-consumer materials |
title_sort |
A method to determine volatile contaminants in polyethylene terephthalate (PET) packages by HDC-GC-FID and its application to post-consumer materials |
author |
Fabris,Samanta |
author_facet |
Fabris,Samanta Freire,Maria Teresa de Alvarenga Wagner,Roger Reyes,Felix Guillermo |
author_role |
author |
author2 |
Freire,Maria Teresa de Alvarenga Wagner,Roger Reyes,Felix Guillermo |
author2_role |
author author author |
dc.contributor.author.fl_str_mv |
Fabris,Samanta Freire,Maria Teresa de Alvarenga Wagner,Roger Reyes,Felix Guillermo |
dc.subject.por.fl_str_mv |
extraction validation gas chromatography PET packaging |
topic |
extraction validation gas chromatography PET packaging |
description |
A simple and low cost method to determine volatile contaminants in post-consumer recycled PET flakes was developed and validated by Headspace Dynamic Concentration and Gas Chromatography-Flame Ionization Detection (HDC-GC-FID). The analytical parameters evaluated by using surrogates include: correlation coefficient, detection limit, quantification limit, accuracy, intra-assay precision, and inter-assay precision. In order to compare the efficiency of the proposed method to recognized automated techniques, post-consumer PET packaging samples collected in Brazil were used. GC-MS was used to confirm the identity of the substances identified in the PET packaging. Some of the identified contaminants were estimated in the post-consumer material at concentrations higher than 220 ng.g-1. The findings in this work corroborate data available in the scientific literature pointing out the suitability of the proposed analytical method. |
publishDate |
2010 |
dc.date.none.fl_str_mv |
2010-12-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0101-20612010000400033 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0101-20612010000400033 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/S0101-20612010000400033 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira de Ciência e Tecnologia de Alimentos |
publisher.none.fl_str_mv |
Sociedade Brasileira de Ciência e Tecnologia de Alimentos |
dc.source.none.fl_str_mv |
Food Science and Technology v.30 n.4 2010 reponame:Food Science and Technology (Campinas) instname:Sociedade Brasileira de Ciência e Tecnologia de Alimentos (SBCTA) instacron:SBCTA |
instname_str |
Sociedade Brasileira de Ciência e Tecnologia de Alimentos (SBCTA) |
instacron_str |
SBCTA |
institution |
SBCTA |
reponame_str |
Food Science and Technology (Campinas) |
collection |
Food Science and Technology (Campinas) |
repository.name.fl_str_mv |
Food Science and Technology (Campinas) - Sociedade Brasileira de Ciência e Tecnologia de Alimentos (SBCTA) |
repository.mail.fl_str_mv |
||revista@sbcta.org.br |
_version_ |
1752126315724537856 |