Adhesion prevention in reabsorbable polyethylene glycol hydrogel (Coseal®) coated polypropylene mesh in rabbits

Detalhes bibliográficos
Autor(a) principal: Quinino,Reynaldo Martins e
Data de Publicação: 2013
Outros Autores: Araújo-Filho,Irami, Lima,Francisco Piganataro, Barbosa,André Luís Costa, Maia,Tatiana de Carvalho, Goldenberg,Alberto
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Acta Cirúrgica Brasileira (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-86502013001200001
Resumo: PURPOSE: To evaluate of postoperative adhesion prevention and inflammatory response to polypropylene mesh, coated with reabsorbable hydrogel of polyethylene glycol (Coseal®) in contact with small bowel in an experimental model in rabbits. METHODS: Twenty female rabbits underwent laparotomy to implant two polypropylene meshes, 2x1cm, in the right and left flanks. The right mesh was protected with Coseal® spray (Group 1) and the left mesh received no treatment after implantation (Group 2). Thirty days after implantation, the rabbits underwent laparoscopy for adhesion analysis; the prosthesis were removed en bloc with the adjacent tissue for microscopic analysis of inflammation. Statistical analysis used the Mann-Whitney test. RESULTS: There was adhesion formation in five meshes (36%) from Group 1 and in 14 meshes (100%) from Group 2, with statistical significance (p<0.01). There were no differences in the inflammatory response, fibrosis, foreign body reaction, presence of collagen and type of inflammatory cells between the two groups. CONCLUSION: Polypropylene mesh coated with Coseal® showed a significantly lower rate of adhesion formation when compared with uncoated meshes, without interfering with inflammatory response.
id SBDPC-1_042d8802b90a9adc1025c194fbdd571b
oai_identifier_str oai:scielo:S0102-86502013001200001
network_acronym_str SBDPC-1
network_name_str Acta Cirúrgica Brasileira (Online)
repository_id_str
spelling Adhesion prevention in reabsorbable polyethylene glycol hydrogel (Coseal®) coated polypropylene mesh in rabbitsTissue AdhesionsPolyethylene GlycolsPolypropylenesRabbitsPURPOSE: To evaluate of postoperative adhesion prevention and inflammatory response to polypropylene mesh, coated with reabsorbable hydrogel of polyethylene glycol (Coseal®) in contact with small bowel in an experimental model in rabbits. METHODS: Twenty female rabbits underwent laparotomy to implant two polypropylene meshes, 2x1cm, in the right and left flanks. The right mesh was protected with Coseal® spray (Group 1) and the left mesh received no treatment after implantation (Group 2). Thirty days after implantation, the rabbits underwent laparoscopy for adhesion analysis; the prosthesis were removed en bloc with the adjacent tissue for microscopic analysis of inflammation. Statistical analysis used the Mann-Whitney test. RESULTS: There was adhesion formation in five meshes (36%) from Group 1 and in 14 meshes (100%) from Group 2, with statistical significance (p<0.01). There were no differences in the inflammatory response, fibrosis, foreign body reaction, presence of collagen and type of inflammatory cells between the two groups. CONCLUSION: Polypropylene mesh coated with Coseal® showed a significantly lower rate of adhesion formation when compared with uncoated meshes, without interfering with inflammatory response.Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia2013-12-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-86502013001200001Acta Cirúrgica Brasileira v.28 n.12 2013reponame:Acta Cirúrgica Brasileira (Online)instname:Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia (SBDPC)instacron:SBDPC10.1590/S0102-86502013001200001info:eu-repo/semantics/openAccessQuinino,Reynaldo Martins eAraújo-Filho,IramiLima,Francisco PiganataroBarbosa,André Luís CostaMaia,Tatiana de CarvalhoGoldenberg,Albertoeng2013-12-04T00:00:00Zoai:scielo:S0102-86502013001200001Revistahttps://www.bvs-vet.org.br/vetindex/periodicos/acta-cirurgica-brasileira/https://old.scielo.br/oai/scielo-oai.php||sgolden@terra.com.br0102-86501678-2674opendoar:2013-12-04T00:00Acta Cirúrgica Brasileira (Online) - Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia (SBDPC)false
dc.title.none.fl_str_mv Adhesion prevention in reabsorbable polyethylene glycol hydrogel (Coseal®) coated polypropylene mesh in rabbits
title Adhesion prevention in reabsorbable polyethylene glycol hydrogel (Coseal®) coated polypropylene mesh in rabbits
spellingShingle Adhesion prevention in reabsorbable polyethylene glycol hydrogel (Coseal®) coated polypropylene mesh in rabbits
Quinino,Reynaldo Martins e
Tissue Adhesions
Polyethylene Glycols
Polypropylenes
Rabbits
title_short Adhesion prevention in reabsorbable polyethylene glycol hydrogel (Coseal®) coated polypropylene mesh in rabbits
title_full Adhesion prevention in reabsorbable polyethylene glycol hydrogel (Coseal®) coated polypropylene mesh in rabbits
title_fullStr Adhesion prevention in reabsorbable polyethylene glycol hydrogel (Coseal®) coated polypropylene mesh in rabbits
title_full_unstemmed Adhesion prevention in reabsorbable polyethylene glycol hydrogel (Coseal®) coated polypropylene mesh in rabbits
title_sort Adhesion prevention in reabsorbable polyethylene glycol hydrogel (Coseal®) coated polypropylene mesh in rabbits
author Quinino,Reynaldo Martins e
author_facet Quinino,Reynaldo Martins e
Araújo-Filho,Irami
Lima,Francisco Piganataro
Barbosa,André Luís Costa
Maia,Tatiana de Carvalho
Goldenberg,Alberto
author_role author
author2 Araújo-Filho,Irami
Lima,Francisco Piganataro
Barbosa,André Luís Costa
Maia,Tatiana de Carvalho
Goldenberg,Alberto
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv Quinino,Reynaldo Martins e
Araújo-Filho,Irami
Lima,Francisco Piganataro
Barbosa,André Luís Costa
Maia,Tatiana de Carvalho
Goldenberg,Alberto
dc.subject.por.fl_str_mv Tissue Adhesions
Polyethylene Glycols
Polypropylenes
Rabbits
topic Tissue Adhesions
Polyethylene Glycols
Polypropylenes
Rabbits
description PURPOSE: To evaluate of postoperative adhesion prevention and inflammatory response to polypropylene mesh, coated with reabsorbable hydrogel of polyethylene glycol (Coseal®) in contact with small bowel in an experimental model in rabbits. METHODS: Twenty female rabbits underwent laparotomy to implant two polypropylene meshes, 2x1cm, in the right and left flanks. The right mesh was protected with Coseal® spray (Group 1) and the left mesh received no treatment after implantation (Group 2). Thirty days after implantation, the rabbits underwent laparoscopy for adhesion analysis; the prosthesis were removed en bloc with the adjacent tissue for microscopic analysis of inflammation. Statistical analysis used the Mann-Whitney test. RESULTS: There was adhesion formation in five meshes (36%) from Group 1 and in 14 meshes (100%) from Group 2, with statistical significance (p<0.01). There were no differences in the inflammatory response, fibrosis, foreign body reaction, presence of collagen and type of inflammatory cells between the two groups. CONCLUSION: Polypropylene mesh coated with Coseal® showed a significantly lower rate of adhesion formation when compared with uncoated meshes, without interfering with inflammatory response.
publishDate 2013
dc.date.none.fl_str_mv 2013-12-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-86502013001200001
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-86502013001200001
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S0102-86502013001200001
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia
publisher.none.fl_str_mv Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia
dc.source.none.fl_str_mv Acta Cirúrgica Brasileira v.28 n.12 2013
reponame:Acta Cirúrgica Brasileira (Online)
instname:Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia (SBDPC)
instacron:SBDPC
instname_str Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia (SBDPC)
instacron_str SBDPC
institution SBDPC
reponame_str Acta Cirúrgica Brasileira (Online)
collection Acta Cirúrgica Brasileira (Online)
repository.name.fl_str_mv Acta Cirúrgica Brasileira (Online) - Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia (SBDPC)
repository.mail.fl_str_mv ||sgolden@terra.com.br
_version_ 1752126442148200448