Exhaled breath condensate collection for nitrite dosage: a safe and low cost adaptation
Autor(a) principal: | |
---|---|
Data de Publicação: | 2010 |
Outros Autores: | , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Acta Cirúrgica Brasileira (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-86502010000200015 |
Resumo: | PURPOSE: Standardization of a simple and low cost technique of exhaled breath condensate (EBC) collection to measure nitrite. METHODS: Two devices were mounted in polystyrene boxes filled either with crushed ice/salt crystals or dry ice/crushed ice. Blood samples were stored at -70º C for posterior nitrite dosages by chemiluminescence and the Griess reaction. RESULTS: a) The use of crushed ice/dry ice or salt revealed sufficient EBC room air collection, but was not efficient for patients under ventilation support; b) the method using crushed ice/salt collected greater EBC volumes, but the nitrite concentrations were not proportional to the volume collected; c) The EBC nitrite values were higher in the surgical group using both methods; d) In the surgical group the nasal clip use diminished the EBC nitrite concentrations in both methods. CONCLUSIONS: The exhaled breath condensate (EBC) methodology collection was efficient on room air breathing. Either cooling methods provided successful EBC collections showing that it is possible to diminish costs, and, amongst the two used methods, the one using crushed ice/salt crystals revealed better efficiency compared to the dry ice method. |
id |
SBDPC-1_09d0d7db528aac5ab8fb5db590360ef0 |
---|---|
oai_identifier_str |
oai:scielo:S0102-86502010000200015 |
network_acronym_str |
SBDPC-1 |
network_name_str |
Acta Cirúrgica Brasileira (Online) |
repository_id_str |
|
spelling |
Exhaled breath condensate collection for nitrite dosage: a safe and low cost adaptationExtracorporeal CirculationThoracic SurgeryNitritesPURPOSE: Standardization of a simple and low cost technique of exhaled breath condensate (EBC) collection to measure nitrite. METHODS: Two devices were mounted in polystyrene boxes filled either with crushed ice/salt crystals or dry ice/crushed ice. Blood samples were stored at -70º C for posterior nitrite dosages by chemiluminescence and the Griess reaction. RESULTS: a) The use of crushed ice/dry ice or salt revealed sufficient EBC room air collection, but was not efficient for patients under ventilation support; b) the method using crushed ice/salt collected greater EBC volumes, but the nitrite concentrations were not proportional to the volume collected; c) The EBC nitrite values were higher in the surgical group using both methods; d) In the surgical group the nasal clip use diminished the EBC nitrite concentrations in both methods. CONCLUSIONS: The exhaled breath condensate (EBC) methodology collection was efficient on room air breathing. Either cooling methods provided successful EBC collections showing that it is possible to diminish costs, and, amongst the two used methods, the one using crushed ice/salt crystals revealed better efficiency compared to the dry ice method.Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia2010-04-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-86502010000200015Acta Cirúrgica Brasileira v.25 n.2 2010reponame:Acta Cirúrgica Brasileira (Online)instname:Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia (SBDPC)instacron:SBDPC10.1590/S0102-86502010000200015info:eu-repo/semantics/openAccessReis,Graziela SaraivaAugusto,Viviane dos SantosSouza,Maria Eliza Jordani deBaldo,Caroline FloreotoRodrigues,Alfredo JoséEvora,Paulo Roberto Barbosaeng2010-10-18T00:00:00Zoai:scielo:S0102-86502010000200015Revistahttps://www.bvs-vet.org.br/vetindex/periodicos/acta-cirurgica-brasileira/https://old.scielo.br/oai/scielo-oai.php||sgolden@terra.com.br0102-86501678-2674opendoar:2010-10-18T00:00Acta Cirúrgica Brasileira (Online) - Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia (SBDPC)false |
dc.title.none.fl_str_mv |
Exhaled breath condensate collection for nitrite dosage: a safe and low cost adaptation |
title |
Exhaled breath condensate collection for nitrite dosage: a safe and low cost adaptation |
spellingShingle |
Exhaled breath condensate collection for nitrite dosage: a safe and low cost adaptation Reis,Graziela Saraiva Extracorporeal Circulation Thoracic Surgery Nitrites |
title_short |
Exhaled breath condensate collection for nitrite dosage: a safe and low cost adaptation |
title_full |
Exhaled breath condensate collection for nitrite dosage: a safe and low cost adaptation |
title_fullStr |
Exhaled breath condensate collection for nitrite dosage: a safe and low cost adaptation |
title_full_unstemmed |
Exhaled breath condensate collection for nitrite dosage: a safe and low cost adaptation |
title_sort |
Exhaled breath condensate collection for nitrite dosage: a safe and low cost adaptation |
author |
Reis,Graziela Saraiva |
author_facet |
Reis,Graziela Saraiva Augusto,Viviane dos Santos Souza,Maria Eliza Jordani de Baldo,Caroline Floreoto Rodrigues,Alfredo José Evora,Paulo Roberto Barbosa |
author_role |
author |
author2 |
Augusto,Viviane dos Santos Souza,Maria Eliza Jordani de Baldo,Caroline Floreoto Rodrigues,Alfredo José Evora,Paulo Roberto Barbosa |
author2_role |
author author author author author |
dc.contributor.author.fl_str_mv |
Reis,Graziela Saraiva Augusto,Viviane dos Santos Souza,Maria Eliza Jordani de Baldo,Caroline Floreoto Rodrigues,Alfredo José Evora,Paulo Roberto Barbosa |
dc.subject.por.fl_str_mv |
Extracorporeal Circulation Thoracic Surgery Nitrites |
topic |
Extracorporeal Circulation Thoracic Surgery Nitrites |
description |
PURPOSE: Standardization of a simple and low cost technique of exhaled breath condensate (EBC) collection to measure nitrite. METHODS: Two devices were mounted in polystyrene boxes filled either with crushed ice/salt crystals or dry ice/crushed ice. Blood samples were stored at -70º C for posterior nitrite dosages by chemiluminescence and the Griess reaction. RESULTS: a) The use of crushed ice/dry ice or salt revealed sufficient EBC room air collection, but was not efficient for patients under ventilation support; b) the method using crushed ice/salt collected greater EBC volumes, but the nitrite concentrations were not proportional to the volume collected; c) The EBC nitrite values were higher in the surgical group using both methods; d) In the surgical group the nasal clip use diminished the EBC nitrite concentrations in both methods. CONCLUSIONS: The exhaled breath condensate (EBC) methodology collection was efficient on room air breathing. Either cooling methods provided successful EBC collections showing that it is possible to diminish costs, and, amongst the two used methods, the one using crushed ice/salt crystals revealed better efficiency compared to the dry ice method. |
publishDate |
2010 |
dc.date.none.fl_str_mv |
2010-04-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-86502010000200015 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-86502010000200015 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/S0102-86502010000200015 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia |
publisher.none.fl_str_mv |
Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia |
dc.source.none.fl_str_mv |
Acta Cirúrgica Brasileira v.25 n.2 2010 reponame:Acta Cirúrgica Brasileira (Online) instname:Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia (SBDPC) instacron:SBDPC |
instname_str |
Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia (SBDPC) |
instacron_str |
SBDPC |
institution |
SBDPC |
reponame_str |
Acta Cirúrgica Brasileira (Online) |
collection |
Acta Cirúrgica Brasileira (Online) |
repository.name.fl_str_mv |
Acta Cirúrgica Brasileira (Online) - Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia (SBDPC) |
repository.mail.fl_str_mv |
||sgolden@terra.com.br |
_version_ |
1752126439964016640 |