An experimental pleural drainage device in hypertensive pneumothorax
Autor(a) principal: | |
---|---|
Data de Publicação: | 2021 |
Outros Autores: | , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Acta Cirúrgica Brasileira (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-86502021000700600 |
Resumo: | ABSTRACT Purpose To develop a specific device for pleural drainage in hypertensive pneumothorax. Methods The prototype was modeled from the free version of a 3D modeling application, printed on a 3D printer using ABS® plastic material, and tested in a pleural drainage simulator. Results Pleural drainage in the simulator using the prototype was feasible and reproducible. Conclusions While the prototype is functional in the simulator, it requires improvement and refinement for use in humans. |
id |
SBDPC-1_3457e473b0d352b7a48529378b1a9c98 |
---|---|
oai_identifier_str |
oai:scielo:S0102-86502021000700600 |
network_acronym_str |
SBDPC-1 |
network_name_str |
Acta Cirúrgica Brasileira (Online) |
repository_id_str |
|
spelling |
An experimental pleural drainage device in hypertensive pneumothoraxPneumothoraxTraumaPulmonary Surgical ProceduresPrintingThree-DimensionalABSTRACT Purpose To develop a specific device for pleural drainage in hypertensive pneumothorax. Methods The prototype was modeled from the free version of a 3D modeling application, printed on a 3D printer using ABS® plastic material, and tested in a pleural drainage simulator. Results Pleural drainage in the simulator using the prototype was feasible and reproducible. Conclusions While the prototype is functional in the simulator, it requires improvement and refinement for use in humans.Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia2021-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-86502021000700600Acta Cirúrgica Brasileira v.36 n.7 2021reponame:Acta Cirúrgica Brasileira (Online)instname:Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia (SBDPC)instacron:SBDPC10.1590/acb360708info:eu-repo/semantics/openAccessPetta,Bruno Filipe ViottoCazanti,Renato FernandoFontes,Carlos Edmundo Rodrigueseng2021-08-20T00:00:00Zoai:scielo:S0102-86502021000700600Revistahttps://www.bvs-vet.org.br/vetindex/periodicos/acta-cirurgica-brasileira/https://old.scielo.br/oai/scielo-oai.php||sgolden@terra.com.br0102-86501678-2674opendoar:2021-08-20T00:00Acta Cirúrgica Brasileira (Online) - Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia (SBDPC)false |
dc.title.none.fl_str_mv |
An experimental pleural drainage device in hypertensive pneumothorax |
title |
An experimental pleural drainage device in hypertensive pneumothorax |
spellingShingle |
An experimental pleural drainage device in hypertensive pneumothorax Petta,Bruno Filipe Viotto Pneumothorax Trauma Pulmonary Surgical Procedures Printing Three-Dimensional |
title_short |
An experimental pleural drainage device in hypertensive pneumothorax |
title_full |
An experimental pleural drainage device in hypertensive pneumothorax |
title_fullStr |
An experimental pleural drainage device in hypertensive pneumothorax |
title_full_unstemmed |
An experimental pleural drainage device in hypertensive pneumothorax |
title_sort |
An experimental pleural drainage device in hypertensive pneumothorax |
author |
Petta,Bruno Filipe Viotto |
author_facet |
Petta,Bruno Filipe Viotto Cazanti,Renato Fernando Fontes,Carlos Edmundo Rodrigues |
author_role |
author |
author2 |
Cazanti,Renato Fernando Fontes,Carlos Edmundo Rodrigues |
author2_role |
author author |
dc.contributor.author.fl_str_mv |
Petta,Bruno Filipe Viotto Cazanti,Renato Fernando Fontes,Carlos Edmundo Rodrigues |
dc.subject.por.fl_str_mv |
Pneumothorax Trauma Pulmonary Surgical Procedures Printing Three-Dimensional |
topic |
Pneumothorax Trauma Pulmonary Surgical Procedures Printing Three-Dimensional |
description |
ABSTRACT Purpose To develop a specific device for pleural drainage in hypertensive pneumothorax. Methods The prototype was modeled from the free version of a 3D modeling application, printed on a 3D printer using ABS® plastic material, and tested in a pleural drainage simulator. Results Pleural drainage in the simulator using the prototype was feasible and reproducible. Conclusions While the prototype is functional in the simulator, it requires improvement and refinement for use in humans. |
publishDate |
2021 |
dc.date.none.fl_str_mv |
2021-01-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-86502021000700600 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-86502021000700600 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/acb360708 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia |
publisher.none.fl_str_mv |
Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia |
dc.source.none.fl_str_mv |
Acta Cirúrgica Brasileira v.36 n.7 2021 reponame:Acta Cirúrgica Brasileira (Online) instname:Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia (SBDPC) instacron:SBDPC |
instname_str |
Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia (SBDPC) |
instacron_str |
SBDPC |
institution |
SBDPC |
reponame_str |
Acta Cirúrgica Brasileira (Online) |
collection |
Acta Cirúrgica Brasileira (Online) |
repository.name.fl_str_mv |
Acta Cirúrgica Brasileira (Online) - Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia (SBDPC) |
repository.mail.fl_str_mv |
||sgolden@terra.com.br |
_version_ |
1752126446271201280 |