Resumo: | ABSTRACT Purpose To investigate the applicability of piezosurgery for cervical ventral slot (CVS), comparing it with the conventional technique of using high-speed burs for bone wear. Methods Thirty rabbits (Oryctolagus cuniculus) were divided into two treatment groups (T1 and T2) corresponding to CVS between C3-C4. In T1, the surgery was performed with piezoelectric apparatus, and in T2 with high-speed burs. The evaluated parameters were: duration of each stage of surgery, temperature variations during CVS, visibility of the surgical field, intra and postoperative complications, and anesthetic monitoring. At 14, 28, and 56 postoperative days, five animals from each treatment group were submitted for histopathological study of the surgical site. Results Compared with T2, T1 had more precise bone cut, and better visibility of the operative field, although it required longer total surgical time (p = 0.02) and triggered a greater number of intraoperative complications (p < 0.01), microscopic lesions in the spinal cord (p < 0.05), and transient neurological deficits in the postoperatively (p < 0.05). Conclusions It is necessary to perform surgical planning and have several tips of the piezoelectric instrument available for the safe use of the piezoelectric device in neurosurgery. |
id |
SBDPC-1_42bd54db091f38711da8d1c68394511e |
---|---|
oai_identifier_str |
oai:scielo:S0102-86502021000600203 |
network_acronym_str |
SBDPC-1 |
network_name_str |
Acta Cirúrgica Brasileira (Online) |
repository_id_str |
|
spelling |
Cervical ventral slot in rabbits (Oryctolagus cuniculus). Piezosurgery versus conventional techniqueNeurosurgeryPiezosurgerySpinal CordRabbitsABSTRACT Purpose To investigate the applicability of piezosurgery for cervical ventral slot (CVS), comparing it with the conventional technique of using high-speed burs for bone wear. Methods Thirty rabbits (Oryctolagus cuniculus) were divided into two treatment groups (T1 and T2) corresponding to CVS between C3-C4. In T1, the surgery was performed with piezoelectric apparatus, and in T2 with high-speed burs. The evaluated parameters were: duration of each stage of surgery, temperature variations during CVS, visibility of the surgical field, intra and postoperative complications, and anesthetic monitoring. At 14, 28, and 56 postoperative days, five animals from each treatment group were submitted for histopathological study of the surgical site. Results Compared with T2, T1 had more precise bone cut, and better visibility of the operative field, although it required longer total surgical time (p = 0.02) and triggered a greater number of intraoperative complications (p < 0.01), microscopic lesions in the spinal cord (p < 0.05), and transient neurological deficits in the postoperatively (p < 0.05). Conclusions It is necessary to perform surgical planning and have several tips of the piezoelectric instrument available for the safe use of the piezoelectric device in neurosurgery.Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia2021-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-86502021000600203Acta Cirúrgica Brasileira v.36 n.6 2021reponame:Acta Cirúrgica Brasileira (Online)instname:Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia (SBDPC)instacron:SBDPC10.1590/acb360606info:eu-repo/semantics/openAccessRoscamp,MarceloHataka,AlessandreZambon,Frederico CarliniFerreira,Danyelle Rayssa CintraMinto,Bruno WatanabeDias,Luis Gustavo Gosuen Gonçalveseng2021-07-06T00:00:00Zoai:scielo:S0102-86502021000600203Revistahttps://www.bvs-vet.org.br/vetindex/periodicos/acta-cirurgica-brasileira/https://old.scielo.br/oai/scielo-oai.php||sgolden@terra.com.br0102-86501678-2674opendoar:2021-07-06T00:00Acta Cirúrgica Brasileira (Online) - Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia (SBDPC)false |
dc.title.none.fl_str_mv |
Cervical ventral slot in rabbits (Oryctolagus cuniculus). Piezosurgery versus conventional technique |
title |
Cervical ventral slot in rabbits (Oryctolagus cuniculus). Piezosurgery versus conventional technique |
spellingShingle |
Cervical ventral slot in rabbits (Oryctolagus cuniculus). Piezosurgery versus conventional technique Roscamp,Marcelo Neurosurgery Piezosurgery Spinal Cord Rabbits |
title_short |
Cervical ventral slot in rabbits (Oryctolagus cuniculus). Piezosurgery versus conventional technique |
title_full |
Cervical ventral slot in rabbits (Oryctolagus cuniculus). Piezosurgery versus conventional technique |
title_fullStr |
Cervical ventral slot in rabbits (Oryctolagus cuniculus). Piezosurgery versus conventional technique |
title_full_unstemmed |
Cervical ventral slot in rabbits (Oryctolagus cuniculus). Piezosurgery versus conventional technique |
title_sort |
Cervical ventral slot in rabbits (Oryctolagus cuniculus). Piezosurgery versus conventional technique |
author |
Roscamp,Marcelo |
author_facet |
Roscamp,Marcelo Hataka,Alessandre Zambon,Frederico Carlini Ferreira,Danyelle Rayssa Cintra Minto,Bruno Watanabe Dias,Luis Gustavo Gosuen Gonçalves |
author_role |
author |
author2 |
Hataka,Alessandre Zambon,Frederico Carlini Ferreira,Danyelle Rayssa Cintra Minto,Bruno Watanabe Dias,Luis Gustavo Gosuen Gonçalves |
author2_role |
author author author author author |
dc.contributor.author.fl_str_mv |
Roscamp,Marcelo Hataka,Alessandre Zambon,Frederico Carlini Ferreira,Danyelle Rayssa Cintra Minto,Bruno Watanabe Dias,Luis Gustavo Gosuen Gonçalves |
dc.subject.por.fl_str_mv |
Neurosurgery Piezosurgery Spinal Cord Rabbits |
topic |
Neurosurgery Piezosurgery Spinal Cord Rabbits |
description |
ABSTRACT Purpose To investigate the applicability of piezosurgery for cervical ventral slot (CVS), comparing it with the conventional technique of using high-speed burs for bone wear. Methods Thirty rabbits (Oryctolagus cuniculus) were divided into two treatment groups (T1 and T2) corresponding to CVS between C3-C4. In T1, the surgery was performed with piezoelectric apparatus, and in T2 with high-speed burs. The evaluated parameters were: duration of each stage of surgery, temperature variations during CVS, visibility of the surgical field, intra and postoperative complications, and anesthetic monitoring. At 14, 28, and 56 postoperative days, five animals from each treatment group were submitted for histopathological study of the surgical site. Results Compared with T2, T1 had more precise bone cut, and better visibility of the operative field, although it required longer total surgical time (p = 0.02) and triggered a greater number of intraoperative complications (p < 0.01), microscopic lesions in the spinal cord (p < 0.05), and transient neurological deficits in the postoperatively (p < 0.05). Conclusions It is necessary to perform surgical planning and have several tips of the piezoelectric instrument available for the safe use of the piezoelectric device in neurosurgery. |
publishDate |
2021 |
dc.date.none.fl_str_mv |
2021-01-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-86502021000600203 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-86502021000600203 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/acb360606 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia |
publisher.none.fl_str_mv |
Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia |
dc.source.none.fl_str_mv |
Acta Cirúrgica Brasileira v.36 n.6 2021 reponame:Acta Cirúrgica Brasileira (Online) instname:Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia (SBDPC) instacron:SBDPC |
instname_str |
Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia (SBDPC) |
instacron_str |
SBDPC |
institution |
SBDPC |
reponame_str |
Acta Cirúrgica Brasileira (Online) |
collection |
Acta Cirúrgica Brasileira (Online) |
repository.name.fl_str_mv |
Acta Cirúrgica Brasileira (Online) - Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia (SBDPC) |
repository.mail.fl_str_mv |
||sgolden@terra.com.br |
_version_ |
1752126446247084032 |