The anatomy of superficial inferior epigastric artery flap

Detalhes bibliográficos
Autor(a) principal: Fathi,Mahdi
Data de Publicação: 2008
Outros Autores: Hatamipour,Ebrahim, Fathi,Hamid Reza, Abbasi,Ali
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Acta Cirúrgica Brasileira (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-86502008000500007
Resumo: PURPOSE: To describe the anatomical variations of superficial inferior epigastric artery (SIEA) flap as a muscle-sparing flap. METHODS: A series of 40 dissections were performed on 20 preserved or fresh male cadavers. The site origin and drainage of vessels, caliber, length, and correlation between diameter and length of pedicle were identified. RESULTS: The SIEA and SIEV were identified at inguinal ligament level in 38 (95%) and 40 (100%) dissections, respectively. The SIEA originated directly from a common femoral artery 22 (57.9%) or a common trunk with other arteries. The SIEA was found within 1 cm of the midpoint of the inguinal ligament in 33 of 38 cases. The meanSD length of SIEA was 3.041.73 (0.5-7) cm. The meanSD caliber of SIEA was 1.450.35 (0.7-2.1) mm. The length of SIEV ranged from 2.2 to 12 cm with a meanSD of 5.452.08 cm. The caliber of SIEV ranged from 1.6 to 4 mm with a meanSD of 2.140.45 mm. The length of SIEA correlated with caliber of arterial pedicle (p<0.001 and correlation coefficient = 0.517). CONCLUSION: The inferior epigastric artery flap can be applied to microsurgical flap transfer, potentially in breast reconstruction, hemifacial atrophy, phalloplasty, or when extremely large amounts of skin coverage are required.
id SBDPC-1_a544e1ff97e03fecce13f419de9eb04c
oai_identifier_str oai:scielo:S0102-86502008000500007
network_acronym_str SBDPC-1
network_name_str Acta Cirúrgica Brasileira (Online)
repository_id_str
spelling The anatomy of superficial inferior epigastric artery flapEpigastric ArteriesSurgical FlapsAnatomyPURPOSE: To describe the anatomical variations of superficial inferior epigastric artery (SIEA) flap as a muscle-sparing flap. METHODS: A series of 40 dissections were performed on 20 preserved or fresh male cadavers. The site origin and drainage of vessels, caliber, length, and correlation between diameter and length of pedicle were identified. RESULTS: The SIEA and SIEV were identified at inguinal ligament level in 38 (95%) and 40 (100%) dissections, respectively. The SIEA originated directly from a common femoral artery 22 (57.9%) or a common trunk with other arteries. The SIEA was found within 1 cm of the midpoint of the inguinal ligament in 33 of 38 cases. The meanSD length of SIEA was 3.041.73 (0.5-7) cm. The meanSD caliber of SIEA was 1.450.35 (0.7-2.1) mm. The length of SIEV ranged from 2.2 to 12 cm with a meanSD of 5.452.08 cm. The caliber of SIEV ranged from 1.6 to 4 mm with a meanSD of 2.140.45 mm. The length of SIEA correlated with caliber of arterial pedicle (p<0.001 and correlation coefficient = 0.517). CONCLUSION: The inferior epigastric artery flap can be applied to microsurgical flap transfer, potentially in breast reconstruction, hemifacial atrophy, phalloplasty, or when extremely large amounts of skin coverage are required.Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia2008-10-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-86502008000500007Acta Cirúrgica Brasileira v.23 n.5 2008reponame:Acta Cirúrgica Brasileira (Online)instname:Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia (SBDPC)instacron:SBDPC10.1590/S0102-86502008000500007info:eu-repo/semantics/openAccessFathi,MahdiHatamipour,EbrahimFathi,Hamid RezaAbbasi,Alieng2008-09-03T00:00:00Zoai:scielo:S0102-86502008000500007Revistahttps://www.bvs-vet.org.br/vetindex/periodicos/acta-cirurgica-brasileira/https://old.scielo.br/oai/scielo-oai.php||sgolden@terra.com.br0102-86501678-2674opendoar:2008-09-03T00:00Acta Cirúrgica Brasileira (Online) - Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia (SBDPC)false
dc.title.none.fl_str_mv The anatomy of superficial inferior epigastric artery flap
title The anatomy of superficial inferior epigastric artery flap
spellingShingle The anatomy of superficial inferior epigastric artery flap
Fathi,Mahdi
Epigastric Arteries
Surgical Flaps
Anatomy
title_short The anatomy of superficial inferior epigastric artery flap
title_full The anatomy of superficial inferior epigastric artery flap
title_fullStr The anatomy of superficial inferior epigastric artery flap
title_full_unstemmed The anatomy of superficial inferior epigastric artery flap
title_sort The anatomy of superficial inferior epigastric artery flap
author Fathi,Mahdi
author_facet Fathi,Mahdi
Hatamipour,Ebrahim
Fathi,Hamid Reza
Abbasi,Ali
author_role author
author2 Hatamipour,Ebrahim
Fathi,Hamid Reza
Abbasi,Ali
author2_role author
author
author
dc.contributor.author.fl_str_mv Fathi,Mahdi
Hatamipour,Ebrahim
Fathi,Hamid Reza
Abbasi,Ali
dc.subject.por.fl_str_mv Epigastric Arteries
Surgical Flaps
Anatomy
topic Epigastric Arteries
Surgical Flaps
Anatomy
description PURPOSE: To describe the anatomical variations of superficial inferior epigastric artery (SIEA) flap as a muscle-sparing flap. METHODS: A series of 40 dissections were performed on 20 preserved or fresh male cadavers. The site origin and drainage of vessels, caliber, length, and correlation between diameter and length of pedicle were identified. RESULTS: The SIEA and SIEV were identified at inguinal ligament level in 38 (95%) and 40 (100%) dissections, respectively. The SIEA originated directly from a common femoral artery 22 (57.9%) or a common trunk with other arteries. The SIEA was found within 1 cm of the midpoint of the inguinal ligament in 33 of 38 cases. The meanSD length of SIEA was 3.041.73 (0.5-7) cm. The meanSD caliber of SIEA was 1.450.35 (0.7-2.1) mm. The length of SIEV ranged from 2.2 to 12 cm with a meanSD of 5.452.08 cm. The caliber of SIEV ranged from 1.6 to 4 mm with a meanSD of 2.140.45 mm. The length of SIEA correlated with caliber of arterial pedicle (p<0.001 and correlation coefficient = 0.517). CONCLUSION: The inferior epigastric artery flap can be applied to microsurgical flap transfer, potentially in breast reconstruction, hemifacial atrophy, phalloplasty, or when extremely large amounts of skin coverage are required.
publishDate 2008
dc.date.none.fl_str_mv 2008-10-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-86502008000500007
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-86502008000500007
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S0102-86502008000500007
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia
publisher.none.fl_str_mv Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia
dc.source.none.fl_str_mv Acta Cirúrgica Brasileira v.23 n.5 2008
reponame:Acta Cirúrgica Brasileira (Online)
instname:Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia (SBDPC)
instacron:SBDPC
instname_str Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia (SBDPC)
instacron_str SBDPC
institution SBDPC
reponame_str Acta Cirúrgica Brasileira (Online)
collection Acta Cirúrgica Brasileira (Online)
repository.name.fl_str_mv Acta Cirúrgica Brasileira (Online) - Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia (SBDPC)
repository.mail.fl_str_mv ||sgolden@terra.com.br
_version_ 1752126439160807424