Biocompatibility of a new device of self-expandable covered and non-covered tracheal stent: comparative study in rats

Detalhes bibliográficos
Autor(a) principal: Rodrigues,Olavo Ribeiro
Data de Publicação: 2013
Outros Autores: Minamoto,Hélio, Canzian,Mauro, Correia,Aristides Tadeu, Jatene,Fabio Biscegli
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Acta Cirúrgica Brasileira (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-86502013000100003
Resumo: PURPOSE: To investigate the compatibility of a new model of self-expandable tracheal stent in rats. METHODS: A new device of polyurethane covered and non - covered stent was placed in the trachea of Wistar rats. Animals were distributed in two groups: the polyurethane covered and non-covered group. Macroscopic parameters included position within the tracheal lumen, adherence to the mucosa, degree of dilatation, permeability and internal diameter. Microscopic findings evaluated were: incorporation, inflammatory activity, granulation tissue and epithelial revetment injuries. The observation follow-up was six weeks. All parameters were quantified based on determined score values. Incorporation of the stents was evaluated based on the observation if the stent was fixed into the trachea or if it could be removed. Degree of dilatation was performed by external diameter measurements. Granulation tissue was evaluated by measurements of height of the tissue growing into the tracheal lumen. RESULTS: 100% of non-covered stents had total attachment to mucosa and 100% of polyurethane covered type had adherence only. Regarding dilatation, granulation tissue, inflammatory activity and internal diameter measurements, there were no significant differences between the groups. Pathological tracheal wall injuries were present in both groups. CONCLUSION: Both models of stent demonstrated biocompatibility with the trachea. Rats are suitable for an experimental model of tracheal stent study.
id SBDPC-1_bf4bcf853562a488e37ba667541086af
oai_identifier_str oai:scielo:S0102-86502013000100003
network_acronym_str SBDPC-1
network_name_str Acta Cirúrgica Brasileira (Online)
repository_id_str
spelling Biocompatibility of a new device of self-expandable covered and non-covered tracheal stent: comparative study in ratsStentsTracheal StenosisMaterials TestingRatsPURPOSE: To investigate the compatibility of a new model of self-expandable tracheal stent in rats. METHODS: A new device of polyurethane covered and non - covered stent was placed in the trachea of Wistar rats. Animals were distributed in two groups: the polyurethane covered and non-covered group. Macroscopic parameters included position within the tracheal lumen, adherence to the mucosa, degree of dilatation, permeability and internal diameter. Microscopic findings evaluated were: incorporation, inflammatory activity, granulation tissue and epithelial revetment injuries. The observation follow-up was six weeks. All parameters were quantified based on determined score values. Incorporation of the stents was evaluated based on the observation if the stent was fixed into the trachea or if it could be removed. Degree of dilatation was performed by external diameter measurements. Granulation tissue was evaluated by measurements of height of the tissue growing into the tracheal lumen. RESULTS: 100% of non-covered stents had total attachment to mucosa and 100% of polyurethane covered type had adherence only. Regarding dilatation, granulation tissue, inflammatory activity and internal diameter measurements, there were no significant differences between the groups. Pathological tracheal wall injuries were present in both groups. CONCLUSION: Both models of stent demonstrated biocompatibility with the trachea. Rats are suitable for an experimental model of tracheal stent study.Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia2013-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-86502013000100003Acta Cirúrgica Brasileira v.28 n.1 2013reponame:Acta Cirúrgica Brasileira (Online)instname:Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia (SBDPC)instacron:SBDPC10.1590/S0102-86502013000100003info:eu-repo/semantics/openAccessRodrigues,Olavo RibeiroMinamoto,HélioCanzian,MauroCorreia,Aristides TadeuJatene,Fabio Bisceglieng2013-01-18T00:00:00Zoai:scielo:S0102-86502013000100003Revistahttps://www.bvs-vet.org.br/vetindex/periodicos/acta-cirurgica-brasileira/https://old.scielo.br/oai/scielo-oai.php||sgolden@terra.com.br0102-86501678-2674opendoar:2013-01-18T00:00Acta Cirúrgica Brasileira (Online) - Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia (SBDPC)false
dc.title.none.fl_str_mv Biocompatibility of a new device of self-expandable covered and non-covered tracheal stent: comparative study in rats
title Biocompatibility of a new device of self-expandable covered and non-covered tracheal stent: comparative study in rats
spellingShingle Biocompatibility of a new device of self-expandable covered and non-covered tracheal stent: comparative study in rats
Rodrigues,Olavo Ribeiro
Stents
Tracheal Stenosis
Materials Testing
Rats
title_short Biocompatibility of a new device of self-expandable covered and non-covered tracheal stent: comparative study in rats
title_full Biocompatibility of a new device of self-expandable covered and non-covered tracheal stent: comparative study in rats
title_fullStr Biocompatibility of a new device of self-expandable covered and non-covered tracheal stent: comparative study in rats
title_full_unstemmed Biocompatibility of a new device of self-expandable covered and non-covered tracheal stent: comparative study in rats
title_sort Biocompatibility of a new device of self-expandable covered and non-covered tracheal stent: comparative study in rats
author Rodrigues,Olavo Ribeiro
author_facet Rodrigues,Olavo Ribeiro
Minamoto,Hélio
Canzian,Mauro
Correia,Aristides Tadeu
Jatene,Fabio Biscegli
author_role author
author2 Minamoto,Hélio
Canzian,Mauro
Correia,Aristides Tadeu
Jatene,Fabio Biscegli
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Rodrigues,Olavo Ribeiro
Minamoto,Hélio
Canzian,Mauro
Correia,Aristides Tadeu
Jatene,Fabio Biscegli
dc.subject.por.fl_str_mv Stents
Tracheal Stenosis
Materials Testing
Rats
topic Stents
Tracheal Stenosis
Materials Testing
Rats
description PURPOSE: To investigate the compatibility of a new model of self-expandable tracheal stent in rats. METHODS: A new device of polyurethane covered and non - covered stent was placed in the trachea of Wistar rats. Animals were distributed in two groups: the polyurethane covered and non-covered group. Macroscopic parameters included position within the tracheal lumen, adherence to the mucosa, degree of dilatation, permeability and internal diameter. Microscopic findings evaluated were: incorporation, inflammatory activity, granulation tissue and epithelial revetment injuries. The observation follow-up was six weeks. All parameters were quantified based on determined score values. Incorporation of the stents was evaluated based on the observation if the stent was fixed into the trachea or if it could be removed. Degree of dilatation was performed by external diameter measurements. Granulation tissue was evaluated by measurements of height of the tissue growing into the tracheal lumen. RESULTS: 100% of non-covered stents had total attachment to mucosa and 100% of polyurethane covered type had adherence only. Regarding dilatation, granulation tissue, inflammatory activity and internal diameter measurements, there were no significant differences between the groups. Pathological tracheal wall injuries were present in both groups. CONCLUSION: Both models of stent demonstrated biocompatibility with the trachea. Rats are suitable for an experimental model of tracheal stent study.
publishDate 2013
dc.date.none.fl_str_mv 2013-01-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-86502013000100003
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-86502013000100003
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S0102-86502013000100003
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia
publisher.none.fl_str_mv Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia
dc.source.none.fl_str_mv Acta Cirúrgica Brasileira v.28 n.1 2013
reponame:Acta Cirúrgica Brasileira (Online)
instname:Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia (SBDPC)
instacron:SBDPC
instname_str Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia (SBDPC)
instacron_str SBDPC
institution SBDPC
reponame_str Acta Cirúrgica Brasileira (Online)
collection Acta Cirúrgica Brasileira (Online)
repository.name.fl_str_mv Acta Cirúrgica Brasileira (Online) - Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia (SBDPC)
repository.mail.fl_str_mv ||sgolden@terra.com.br
_version_ 1752126441410002944