Lower energy and pulse stacking. A safer alternative for skin tightening using fractional CO2 laser

Detalhes bibliográficos
Autor(a) principal: Motta,Marcos Matias
Data de Publicação: 2016
Outros Autores: Stelini,Rafael Fantelli, Calderoni,Davi Reis, Gilioli,Rovilson, Kharmandayan,Paulo
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Acta Cirúrgica Brasileira (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-86502016000100028
Resumo: PURPOSE : To evaluate the effect of different energies and stacking in skin shrinkage. METHODS : Three decreasing settings of a fractional CO2 laser were applied to the abdomen of Twenty five Wistar rats divided into three groups. Group I (n=5) was histologically evaluated for microthermal zones dimensions. Groups II and III (n=10 each) were macroscopic evaluated with freeware ImageJ for area contraction immediately and after 30 and 60 days. RESULTS : No statistical significance was found within microthermal zone histological dimensions (Group I) in all settings studied. (Ablation depth: 76.90 to 97.18µm; Coagulation depth: 186.01 to 219.84 µm). In Group II, macroscopic evaluation showed that all settings cause significant immediate skin contraction. The highest setting cause significant more intense tightening effect initially, contracting skin area from 258.65 to 179.09 mm2. The same pattern was observed in Group III. At 30 and 60 days, the lowest setting significantly sustained contraction. CONCLUSION : Lower fractional CO2 laser energies associated to pulse stacking could cause consistent and long lasting tissue contraction in rats.
id SBDPC-1_c04a83975126e3c22787f43d7b49470a
oai_identifier_str oai:scielo:S0102-86502016000100028
network_acronym_str SBDPC-1
network_name_str Acta Cirúrgica Brasileira (Online)
repository_id_str
spelling Lower energy and pulse stacking. A safer alternative for skin tightening using fractional CO2 laserLasers, GasSkin AgingLaser TherapyRats PURPOSE : To evaluate the effect of different energies and stacking in skin shrinkage. METHODS : Three decreasing settings of a fractional CO2 laser were applied to the abdomen of Twenty five Wistar rats divided into three groups. Group I (n=5) was histologically evaluated for microthermal zones dimensions. Groups II and III (n=10 each) were macroscopic evaluated with freeware ImageJ for area contraction immediately and after 30 and 60 days. RESULTS : No statistical significance was found within microthermal zone histological dimensions (Group I) in all settings studied. (Ablation depth: 76.90 to 97.18µm; Coagulation depth: 186.01 to 219.84 µm). In Group II, macroscopic evaluation showed that all settings cause significant immediate skin contraction. The highest setting cause significant more intense tightening effect initially, contracting skin area from 258.65 to 179.09 mm2. The same pattern was observed in Group III. At 30 and 60 days, the lowest setting significantly sustained contraction. CONCLUSION : Lower fractional CO2 laser energies associated to pulse stacking could cause consistent and long lasting tissue contraction in rats.Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia2016-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-86502016000100028Acta Cirúrgica Brasileira v.31 n.1 2016reponame:Acta Cirúrgica Brasileira (Online)instname:Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia (SBDPC)instacron:SBDPC10.1590/S0102-865020160010000005info:eu-repo/semantics/openAccessMotta,Marcos MatiasStelini,Rafael FantelliCalderoni,Davi ReisGilioli,RovilsonKharmandayan,Pauloeng2016-01-28T00:00:00Zoai:scielo:S0102-86502016000100028Revistahttps://www.bvs-vet.org.br/vetindex/periodicos/acta-cirurgica-brasileira/https://old.scielo.br/oai/scielo-oai.php||sgolden@terra.com.br0102-86501678-2674opendoar:2016-01-28T00:00Acta Cirúrgica Brasileira (Online) - Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia (SBDPC)false
dc.title.none.fl_str_mv Lower energy and pulse stacking. A safer alternative for skin tightening using fractional CO2 laser
title Lower energy and pulse stacking. A safer alternative for skin tightening using fractional CO2 laser
spellingShingle Lower energy and pulse stacking. A safer alternative for skin tightening using fractional CO2 laser
Motta,Marcos Matias
Lasers, Gas
Skin Aging
Laser Therapy
Rats
title_short Lower energy and pulse stacking. A safer alternative for skin tightening using fractional CO2 laser
title_full Lower energy and pulse stacking. A safer alternative for skin tightening using fractional CO2 laser
title_fullStr Lower energy and pulse stacking. A safer alternative for skin tightening using fractional CO2 laser
title_full_unstemmed Lower energy and pulse stacking. A safer alternative for skin tightening using fractional CO2 laser
title_sort Lower energy and pulse stacking. A safer alternative for skin tightening using fractional CO2 laser
author Motta,Marcos Matias
author_facet Motta,Marcos Matias
Stelini,Rafael Fantelli
Calderoni,Davi Reis
Gilioli,Rovilson
Kharmandayan,Paulo
author_role author
author2 Stelini,Rafael Fantelli
Calderoni,Davi Reis
Gilioli,Rovilson
Kharmandayan,Paulo
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Motta,Marcos Matias
Stelini,Rafael Fantelli
Calderoni,Davi Reis
Gilioli,Rovilson
Kharmandayan,Paulo
dc.subject.por.fl_str_mv Lasers, Gas
Skin Aging
Laser Therapy
Rats
topic Lasers, Gas
Skin Aging
Laser Therapy
Rats
description PURPOSE : To evaluate the effect of different energies and stacking in skin shrinkage. METHODS : Three decreasing settings of a fractional CO2 laser were applied to the abdomen of Twenty five Wistar rats divided into three groups. Group I (n=5) was histologically evaluated for microthermal zones dimensions. Groups II and III (n=10 each) were macroscopic evaluated with freeware ImageJ for area contraction immediately and after 30 and 60 days. RESULTS : No statistical significance was found within microthermal zone histological dimensions (Group I) in all settings studied. (Ablation depth: 76.90 to 97.18µm; Coagulation depth: 186.01 to 219.84 µm). In Group II, macroscopic evaluation showed that all settings cause significant immediate skin contraction. The highest setting cause significant more intense tightening effect initially, contracting skin area from 258.65 to 179.09 mm2. The same pattern was observed in Group III. At 30 and 60 days, the lowest setting significantly sustained contraction. CONCLUSION : Lower fractional CO2 laser energies associated to pulse stacking could cause consistent and long lasting tissue contraction in rats.
publishDate 2016
dc.date.none.fl_str_mv 2016-01-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-86502016000100028
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-86502016000100028
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S0102-865020160010000005
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia
publisher.none.fl_str_mv Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia
dc.source.none.fl_str_mv Acta Cirúrgica Brasileira v.31 n.1 2016
reponame:Acta Cirúrgica Brasileira (Online)
instname:Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia (SBDPC)
instacron:SBDPC
instname_str Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia (SBDPC)
instacron_str SBDPC
institution SBDPC
reponame_str Acta Cirúrgica Brasileira (Online)
collection Acta Cirúrgica Brasileira (Online)
repository.name.fl_str_mv Acta Cirúrgica Brasileira (Online) - Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia (SBDPC)
repository.mail.fl_str_mv ||sgolden@terra.com.br
_version_ 1752126443572166656