Technique for implanting intramuscular electrodes in the diaphragm by videolaparoscopy in pigs

Detalhes bibliográficos
Autor(a) principal: Ghedini,Rodrigo Guellner
Data de Publicação: 2016
Outros Autores: Paludo,Artur de Oliveira, Mariano,Rodrigo, Silva,Éverton Franco, Thomaz,Leonardo Dalla Giacomassa Rocha, Diehl,Gustavo, Simoneti,Lucas Elias Lise, Drachler,Igor Pires, Andrade,Cristiano Feijó
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Acta Cirúrgica Brasileira (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-86502016000200138
Resumo: PURPOSE: To describe a novel approach for implanting intramuscular electrodes in the diaphragm through videolaparoscopy. METHODS: We used twelve pigs for this videolaparoscopic technique, which permits at the same time to explore the diaphragm, to locate its motor points and to fix the electrodes in the diaphragm bilaterally. In this technique we used three trocars: one portal for a 10-mm 0° viewing angle laparoscope, one portal for the manipulation of structures and another for electrode implantation. RESULTS: All animals survived the procedure without pneumothorax/capnothorax or other complication. Implanted electrodes provided an appropriate interface between the muscle and the electrical current generator, and electroventilation was satisfactorily generated in all animals. CONCLUSION: This videolaparoscopic technique with three trocars enables the exploration and identification of motor points and an efficient fixation of one or two electrodes in each hemidiaphragm.
id SBDPC-1_d663142a61ad4fa52701726ffa72c003
oai_identifier_str oai:scielo:S0102-86502016000200138
network_acronym_str SBDPC-1
network_name_str Acta Cirúrgica Brasileira (Online)
repository_id_str
spelling Technique for implanting intramuscular electrodes in the diaphragm by videolaparoscopy in pigsLaparoscopyDiaphragmPacemaker, ArtificialSwine PURPOSE: To describe a novel approach for implanting intramuscular electrodes in the diaphragm through videolaparoscopy. METHODS: We used twelve pigs for this videolaparoscopic technique, which permits at the same time to explore the diaphragm, to locate its motor points and to fix the electrodes in the diaphragm bilaterally. In this technique we used three trocars: one portal for a 10-mm 0° viewing angle laparoscope, one portal for the manipulation of structures and another for electrode implantation. RESULTS: All animals survived the procedure without pneumothorax/capnothorax or other complication. Implanted electrodes provided an appropriate interface between the muscle and the electrical current generator, and electroventilation was satisfactorily generated in all animals. CONCLUSION: This videolaparoscopic technique with three trocars enables the exploration and identification of motor points and an efficient fixation of one or two electrodes in each hemidiaphragm.Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia2016-02-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-86502016000200138Acta Cirúrgica Brasileira v.31 n.2 2016reponame:Acta Cirúrgica Brasileira (Online)instname:Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia (SBDPC)instacron:SBDPC10.1590/S0102-865020160020000009info:eu-repo/semantics/openAccessGhedini,Rodrigo GuellnerPaludo,Artur de OliveiraMariano,RodrigoSilva,Éverton FrancoThomaz,Leonardo Dalla Giacomassa RochaDiehl,GustavoSimoneti,Lucas Elias LiseDrachler,Igor PiresAndrade,Cristiano Feijóeng2016-03-03T00:00:00Zoai:scielo:S0102-86502016000200138Revistahttps://www.bvs-vet.org.br/vetindex/periodicos/acta-cirurgica-brasileira/https://old.scielo.br/oai/scielo-oai.php||sgolden@terra.com.br0102-86501678-2674opendoar:2016-03-03T00:00Acta Cirúrgica Brasileira (Online) - Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia (SBDPC)false
dc.title.none.fl_str_mv Technique for implanting intramuscular electrodes in the diaphragm by videolaparoscopy in pigs
title Technique for implanting intramuscular electrodes in the diaphragm by videolaparoscopy in pigs
spellingShingle Technique for implanting intramuscular electrodes in the diaphragm by videolaparoscopy in pigs
Ghedini,Rodrigo Guellner
Laparoscopy
Diaphragm
Pacemaker, Artificial
Swine
title_short Technique for implanting intramuscular electrodes in the diaphragm by videolaparoscopy in pigs
title_full Technique for implanting intramuscular electrodes in the diaphragm by videolaparoscopy in pigs
title_fullStr Technique for implanting intramuscular electrodes in the diaphragm by videolaparoscopy in pigs
title_full_unstemmed Technique for implanting intramuscular electrodes in the diaphragm by videolaparoscopy in pigs
title_sort Technique for implanting intramuscular electrodes in the diaphragm by videolaparoscopy in pigs
author Ghedini,Rodrigo Guellner
author_facet Ghedini,Rodrigo Guellner
Paludo,Artur de Oliveira
Mariano,Rodrigo
Silva,Éverton Franco
Thomaz,Leonardo Dalla Giacomassa Rocha
Diehl,Gustavo
Simoneti,Lucas Elias Lise
Drachler,Igor Pires
Andrade,Cristiano Feijó
author_role author
author2 Paludo,Artur de Oliveira
Mariano,Rodrigo
Silva,Éverton Franco
Thomaz,Leonardo Dalla Giacomassa Rocha
Diehl,Gustavo
Simoneti,Lucas Elias Lise
Drachler,Igor Pires
Andrade,Cristiano Feijó
author2_role author
author
author
author
author
author
author
author
dc.contributor.author.fl_str_mv Ghedini,Rodrigo Guellner
Paludo,Artur de Oliveira
Mariano,Rodrigo
Silva,Éverton Franco
Thomaz,Leonardo Dalla Giacomassa Rocha
Diehl,Gustavo
Simoneti,Lucas Elias Lise
Drachler,Igor Pires
Andrade,Cristiano Feijó
dc.subject.por.fl_str_mv Laparoscopy
Diaphragm
Pacemaker, Artificial
Swine
topic Laparoscopy
Diaphragm
Pacemaker, Artificial
Swine
description PURPOSE: To describe a novel approach for implanting intramuscular electrodes in the diaphragm through videolaparoscopy. METHODS: We used twelve pigs for this videolaparoscopic technique, which permits at the same time to explore the diaphragm, to locate its motor points and to fix the electrodes in the diaphragm bilaterally. In this technique we used three trocars: one portal for a 10-mm 0° viewing angle laparoscope, one portal for the manipulation of structures and another for electrode implantation. RESULTS: All animals survived the procedure without pneumothorax/capnothorax or other complication. Implanted electrodes provided an appropriate interface between the muscle and the electrical current generator, and electroventilation was satisfactorily generated in all animals. CONCLUSION: This videolaparoscopic technique with three trocars enables the exploration and identification of motor points and an efficient fixation of one or two electrodes in each hemidiaphragm.
publishDate 2016
dc.date.none.fl_str_mv 2016-02-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-86502016000200138
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-86502016000200138
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S0102-865020160020000009
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia
publisher.none.fl_str_mv Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia
dc.source.none.fl_str_mv Acta Cirúrgica Brasileira v.31 n.2 2016
reponame:Acta Cirúrgica Brasileira (Online)
instname:Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia (SBDPC)
instacron:SBDPC
instname_str Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia (SBDPC)
instacron_str SBDPC
institution SBDPC
reponame_str Acta Cirúrgica Brasileira (Online)
collection Acta Cirúrgica Brasileira (Online)
repository.name.fl_str_mv Acta Cirúrgica Brasileira (Online) - Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia (SBDPC)
repository.mail.fl_str_mv ||sgolden@terra.com.br
_version_ 1752126443598381056