Technique for implanting intramuscular electrodes in the diaphragm by videolaparoscopy in pigs
Autor(a) principal: | |
---|---|
Data de Publicação: | 2016 |
Outros Autores: | , , , , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Acta Cirúrgica Brasileira (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-86502016000200138 |
Resumo: | PURPOSE: To describe a novel approach for implanting intramuscular electrodes in the diaphragm through videolaparoscopy. METHODS: We used twelve pigs for this videolaparoscopic technique, which permits at the same time to explore the diaphragm, to locate its motor points and to fix the electrodes in the diaphragm bilaterally. In this technique we used three trocars: one portal for a 10-mm 0° viewing angle laparoscope, one portal for the manipulation of structures and another for electrode implantation. RESULTS: All animals survived the procedure without pneumothorax/capnothorax or other complication. Implanted electrodes provided an appropriate interface between the muscle and the electrical current generator, and electroventilation was satisfactorily generated in all animals. CONCLUSION: This videolaparoscopic technique with three trocars enables the exploration and identification of motor points and an efficient fixation of one or two electrodes in each hemidiaphragm. |
id |
SBDPC-1_d663142a61ad4fa52701726ffa72c003 |
---|---|
oai_identifier_str |
oai:scielo:S0102-86502016000200138 |
network_acronym_str |
SBDPC-1 |
network_name_str |
Acta Cirúrgica Brasileira (Online) |
repository_id_str |
|
spelling |
Technique for implanting intramuscular electrodes in the diaphragm by videolaparoscopy in pigsLaparoscopyDiaphragmPacemaker, ArtificialSwine PURPOSE: To describe a novel approach for implanting intramuscular electrodes in the diaphragm through videolaparoscopy. METHODS: We used twelve pigs for this videolaparoscopic technique, which permits at the same time to explore the diaphragm, to locate its motor points and to fix the electrodes in the diaphragm bilaterally. In this technique we used three trocars: one portal for a 10-mm 0° viewing angle laparoscope, one portal for the manipulation of structures and another for electrode implantation. RESULTS: All animals survived the procedure without pneumothorax/capnothorax or other complication. Implanted electrodes provided an appropriate interface between the muscle and the electrical current generator, and electroventilation was satisfactorily generated in all animals. CONCLUSION: This videolaparoscopic technique with three trocars enables the exploration and identification of motor points and an efficient fixation of one or two electrodes in each hemidiaphragm.Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia2016-02-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-86502016000200138Acta Cirúrgica Brasileira v.31 n.2 2016reponame:Acta Cirúrgica Brasileira (Online)instname:Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia (SBDPC)instacron:SBDPC10.1590/S0102-865020160020000009info:eu-repo/semantics/openAccessGhedini,Rodrigo GuellnerPaludo,Artur de OliveiraMariano,RodrigoSilva,Éverton FrancoThomaz,Leonardo Dalla Giacomassa RochaDiehl,GustavoSimoneti,Lucas Elias LiseDrachler,Igor PiresAndrade,Cristiano Feijóeng2016-03-03T00:00:00Zoai:scielo:S0102-86502016000200138Revistahttps://www.bvs-vet.org.br/vetindex/periodicos/acta-cirurgica-brasileira/https://old.scielo.br/oai/scielo-oai.php||sgolden@terra.com.br0102-86501678-2674opendoar:2016-03-03T00:00Acta Cirúrgica Brasileira (Online) - Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia (SBDPC)false |
dc.title.none.fl_str_mv |
Technique for implanting intramuscular electrodes in the diaphragm by videolaparoscopy in pigs |
title |
Technique for implanting intramuscular electrodes in the diaphragm by videolaparoscopy in pigs |
spellingShingle |
Technique for implanting intramuscular electrodes in the diaphragm by videolaparoscopy in pigs Ghedini,Rodrigo Guellner Laparoscopy Diaphragm Pacemaker, Artificial Swine |
title_short |
Technique for implanting intramuscular electrodes in the diaphragm by videolaparoscopy in pigs |
title_full |
Technique for implanting intramuscular electrodes in the diaphragm by videolaparoscopy in pigs |
title_fullStr |
Technique for implanting intramuscular electrodes in the diaphragm by videolaparoscopy in pigs |
title_full_unstemmed |
Technique for implanting intramuscular electrodes in the diaphragm by videolaparoscopy in pigs |
title_sort |
Technique for implanting intramuscular electrodes in the diaphragm by videolaparoscopy in pigs |
author |
Ghedini,Rodrigo Guellner |
author_facet |
Ghedini,Rodrigo Guellner Paludo,Artur de Oliveira Mariano,Rodrigo Silva,Éverton Franco Thomaz,Leonardo Dalla Giacomassa Rocha Diehl,Gustavo Simoneti,Lucas Elias Lise Drachler,Igor Pires Andrade,Cristiano Feijó |
author_role |
author |
author2 |
Paludo,Artur de Oliveira Mariano,Rodrigo Silva,Éverton Franco Thomaz,Leonardo Dalla Giacomassa Rocha Diehl,Gustavo Simoneti,Lucas Elias Lise Drachler,Igor Pires Andrade,Cristiano Feijó |
author2_role |
author author author author author author author author |
dc.contributor.author.fl_str_mv |
Ghedini,Rodrigo Guellner Paludo,Artur de Oliveira Mariano,Rodrigo Silva,Éverton Franco Thomaz,Leonardo Dalla Giacomassa Rocha Diehl,Gustavo Simoneti,Lucas Elias Lise Drachler,Igor Pires Andrade,Cristiano Feijó |
dc.subject.por.fl_str_mv |
Laparoscopy Diaphragm Pacemaker, Artificial Swine |
topic |
Laparoscopy Diaphragm Pacemaker, Artificial Swine |
description |
PURPOSE: To describe a novel approach for implanting intramuscular electrodes in the diaphragm through videolaparoscopy. METHODS: We used twelve pigs for this videolaparoscopic technique, which permits at the same time to explore the diaphragm, to locate its motor points and to fix the electrodes in the diaphragm bilaterally. In this technique we used three trocars: one portal for a 10-mm 0° viewing angle laparoscope, one portal for the manipulation of structures and another for electrode implantation. RESULTS: All animals survived the procedure without pneumothorax/capnothorax or other complication. Implanted electrodes provided an appropriate interface between the muscle and the electrical current generator, and electroventilation was satisfactorily generated in all animals. CONCLUSION: This videolaparoscopic technique with three trocars enables the exploration and identification of motor points and an efficient fixation of one or two electrodes in each hemidiaphragm. |
publishDate |
2016 |
dc.date.none.fl_str_mv |
2016-02-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-86502016000200138 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-86502016000200138 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/S0102-865020160020000009 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia |
publisher.none.fl_str_mv |
Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia |
dc.source.none.fl_str_mv |
Acta Cirúrgica Brasileira v.31 n.2 2016 reponame:Acta Cirúrgica Brasileira (Online) instname:Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia (SBDPC) instacron:SBDPC |
instname_str |
Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia (SBDPC) |
instacron_str |
SBDPC |
institution |
SBDPC |
reponame_str |
Acta Cirúrgica Brasileira (Online) |
collection |
Acta Cirúrgica Brasileira (Online) |
repository.name.fl_str_mv |
Acta Cirúrgica Brasileira (Online) - Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia (SBDPC) |
repository.mail.fl_str_mv |
||sgolden@terra.com.br |
_version_ |
1752126443598381056 |