Experimental study comparing the tensile strength of different surgical meshes following aponeurotic-muscle deformity synthesis on Wistar rats
Autor(a) principal: | |
---|---|
Data de Publicação: | 2007 |
Outros Autores: | , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Acta Cirúrgica Brasileira (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-86502007000100009 |
Resumo: | PURPOSE: To assess the tensile strength of polypropylene and polypropylene associated with polyglactin meshes (Vypro II® - Ethicon®, Somerville, NJ, USA) in a situation of partial separation of abdominal muscle aponeurosis on rats. METHODS: Thirty rats were used of the Wistar strain, which were randomized into two groups of 15 specimens each. In both groups an aponeurotic-muscle deformity was created on the abdominal wall measuring 3.0 x 1.0 cm, which was closed with polypropylene mesh (polypropylene group) or Vypro® mesh (vypro group). After 28 days the rats underwent euthanasia and an area was removed from the abdominal wall with which a strip was made measuring 2.0 cm in length and 6.0 cm in width comprising the abdominal muscles with the implanted mesh. This sample was placed in a mechanical test machine in which a constant force was applied contrary to the tissue strips. Maximum force expressed in Newton was considered until full rupture of the sample occurred. The non-parametric Kruskal - Wallis test was used for statistical analysis admitting p<0.05. RESULTS: Out of the thirty animals, there were two deaths in the vypro group and one unit in the polypropylene group was lost. One animal in the polypropylene group developed hernia during the study and another one developed granuloma of the abdominal wall. All animals in both groups developed epiplon adherence to the mesh. The average force was 48.08 N for the polypropylene group and 45.32 for the vypro® group. CONCLUSION: In these experimental conditions it could be observed that there is no statistically significant difference in the rupture force of the polypropylene and Vypro® meshes (p=0.54). |
id |
SBDPC-1_e1f03342be1548f0d106434ecb6320e0 |
---|---|
oai_identifier_str |
oai:scielo:S0102-86502007000100009 |
network_acronym_str |
SBDPC-1 |
network_name_str |
Acta Cirúrgica Brasileira (Online) |
repository_id_str |
|
spelling |
Experimental study comparing the tensile strength of different surgical meshes following aponeurotic-muscle deformity synthesis on Wistar ratsSurgerySurgical MeshTensile StrengthWistar, RatsPURPOSE: To assess the tensile strength of polypropylene and polypropylene associated with polyglactin meshes (Vypro II® - Ethicon®, Somerville, NJ, USA) in a situation of partial separation of abdominal muscle aponeurosis on rats. METHODS: Thirty rats were used of the Wistar strain, which were randomized into two groups of 15 specimens each. In both groups an aponeurotic-muscle deformity was created on the abdominal wall measuring 3.0 x 1.0 cm, which was closed with polypropylene mesh (polypropylene group) or Vypro® mesh (vypro group). After 28 days the rats underwent euthanasia and an area was removed from the abdominal wall with which a strip was made measuring 2.0 cm in length and 6.0 cm in width comprising the abdominal muscles with the implanted mesh. This sample was placed in a mechanical test machine in which a constant force was applied contrary to the tissue strips. Maximum force expressed in Newton was considered until full rupture of the sample occurred. The non-parametric Kruskal - Wallis test was used for statistical analysis admitting p<0.05. RESULTS: Out of the thirty animals, there were two deaths in the vypro group and one unit in the polypropylene group was lost. One animal in the polypropylene group developed hernia during the study and another one developed granuloma of the abdominal wall. All animals in both groups developed epiplon adherence to the mesh. The average force was 48.08 N for the polypropylene group and 45.32 for the vypro® group. CONCLUSION: In these experimental conditions it could be observed that there is no statistically significant difference in the rupture force of the polypropylene and Vypro® meshes (p=0.54).Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia2007-02-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-86502007000100009Acta Cirúrgica Brasileira v.22 n.1 2007reponame:Acta Cirúrgica Brasileira (Online)instname:Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia (SBDPC)instacron:SBDPC10.1590/S0102-86502007000100009info:eu-repo/semantics/openAccessd'Acampora,Armando JoséKestering,Darlan de MedeirosSoldi,Marly da SilveiraRossi,Lucas Félixeng2007-03-15T00:00:00Zoai:scielo:S0102-86502007000100009Revistahttps://www.bvs-vet.org.br/vetindex/periodicos/acta-cirurgica-brasileira/https://old.scielo.br/oai/scielo-oai.php||sgolden@terra.com.br0102-86501678-2674opendoar:2007-03-15T00:00Acta Cirúrgica Brasileira (Online) - Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia (SBDPC)false |
dc.title.none.fl_str_mv |
Experimental study comparing the tensile strength of different surgical meshes following aponeurotic-muscle deformity synthesis on Wistar rats |
title |
Experimental study comparing the tensile strength of different surgical meshes following aponeurotic-muscle deformity synthesis on Wistar rats |
spellingShingle |
Experimental study comparing the tensile strength of different surgical meshes following aponeurotic-muscle deformity synthesis on Wistar rats d'Acampora,Armando José Surgery Surgical Mesh Tensile Strength Wistar, Rats |
title_short |
Experimental study comparing the tensile strength of different surgical meshes following aponeurotic-muscle deformity synthesis on Wistar rats |
title_full |
Experimental study comparing the tensile strength of different surgical meshes following aponeurotic-muscle deformity synthesis on Wistar rats |
title_fullStr |
Experimental study comparing the tensile strength of different surgical meshes following aponeurotic-muscle deformity synthesis on Wistar rats |
title_full_unstemmed |
Experimental study comparing the tensile strength of different surgical meshes following aponeurotic-muscle deformity synthesis on Wistar rats |
title_sort |
Experimental study comparing the tensile strength of different surgical meshes following aponeurotic-muscle deformity synthesis on Wistar rats |
author |
d'Acampora,Armando José |
author_facet |
d'Acampora,Armando José Kestering,Darlan de Medeiros Soldi,Marly da Silveira Rossi,Lucas Félix |
author_role |
author |
author2 |
Kestering,Darlan de Medeiros Soldi,Marly da Silveira Rossi,Lucas Félix |
author2_role |
author author author |
dc.contributor.author.fl_str_mv |
d'Acampora,Armando José Kestering,Darlan de Medeiros Soldi,Marly da Silveira Rossi,Lucas Félix |
dc.subject.por.fl_str_mv |
Surgery Surgical Mesh Tensile Strength Wistar, Rats |
topic |
Surgery Surgical Mesh Tensile Strength Wistar, Rats |
description |
PURPOSE: To assess the tensile strength of polypropylene and polypropylene associated with polyglactin meshes (Vypro II® - Ethicon®, Somerville, NJ, USA) in a situation of partial separation of abdominal muscle aponeurosis on rats. METHODS: Thirty rats were used of the Wistar strain, which were randomized into two groups of 15 specimens each. In both groups an aponeurotic-muscle deformity was created on the abdominal wall measuring 3.0 x 1.0 cm, which was closed with polypropylene mesh (polypropylene group) or Vypro® mesh (vypro group). After 28 days the rats underwent euthanasia and an area was removed from the abdominal wall with which a strip was made measuring 2.0 cm in length and 6.0 cm in width comprising the abdominal muscles with the implanted mesh. This sample was placed in a mechanical test machine in which a constant force was applied contrary to the tissue strips. Maximum force expressed in Newton was considered until full rupture of the sample occurred. The non-parametric Kruskal - Wallis test was used for statistical analysis admitting p<0.05. RESULTS: Out of the thirty animals, there were two deaths in the vypro group and one unit in the polypropylene group was lost. One animal in the polypropylene group developed hernia during the study and another one developed granuloma of the abdominal wall. All animals in both groups developed epiplon adherence to the mesh. The average force was 48.08 N for the polypropylene group and 45.32 for the vypro® group. CONCLUSION: In these experimental conditions it could be observed that there is no statistically significant difference in the rupture force of the polypropylene and Vypro® meshes (p=0.54). |
publishDate |
2007 |
dc.date.none.fl_str_mv |
2007-02-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-86502007000100009 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-86502007000100009 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/S0102-86502007000100009 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia |
publisher.none.fl_str_mv |
Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia |
dc.source.none.fl_str_mv |
Acta Cirúrgica Brasileira v.22 n.1 2007 reponame:Acta Cirúrgica Brasileira (Online) instname:Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia (SBDPC) instacron:SBDPC |
instname_str |
Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia (SBDPC) |
instacron_str |
SBDPC |
institution |
SBDPC |
reponame_str |
Acta Cirúrgica Brasileira (Online) |
collection |
Acta Cirúrgica Brasileira (Online) |
repository.name.fl_str_mv |
Acta Cirúrgica Brasileira (Online) - Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia (SBDPC) |
repository.mail.fl_str_mv |
||sgolden@terra.com.br |
_version_ |
1752126438600867840 |