EVALUATION OF DROPLET SPECTRA OF THE SPRAY TIP AD 11002 USING DIFFERENT TECHNIQUES

Detalhes bibliográficos
Autor(a) principal: Cunha,João P. A. R. da
Data de Publicação: 2019
Outros Autores: Reis,Elton F. dos, Assunção,Heli H. T. de, Landim,Thiago N.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Engenharia Agrícola
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-69162019000400476
Resumo: ABSTRACT Knowledge of droplet spectra generated by spray nozzle tips is important to ensure the quality of applications of plant protection products. However, there are different methods for this evaluation, which can cause difficulty in interpreting the results. This study aimed to evaluate the droplet spectra produced by the flat fan spray tip AD 11002 operated under different pressures and using different techniques and equipment. The volume median diameter (VMD), percentage of spray volume in droplets smaller than 100 µm diameter and relative spam (RS), considering pressures of 200, 300, and 400 kPa were determined using two direct measurement equipment (Spraytec and Shadow Sizer), based on laser diffraction and image analysis, respectively, and a measure based on indirect analysis, through the digitization of water-sensitive paper. Thus, the use of different analysis techniques led to variations of the analyzed parameters. Among the direct measurement equipment, a difference of up to 58% was observed in VMD. The use of water-sensitive paper to characterize droplet spectra must be carried out with great discretion because there is an underestimation of fine droplets. Pressure variations of 200 to 400 kPa did not influence VMD and RS.
id SBEA-1_0147d759b8a9c2d7690b076823f958ee
oai_identifier_str oai:scielo:S0100-69162019000400476
network_acronym_str SBEA-1
network_name_str Engenharia Agrícola
repository_id_str
spelling EVALUATION OF DROPLET SPECTRA OF THE SPRAY TIP AD 11002 USING DIFFERENT TECHNIQUESapplication technologydroplet sizewater-sensitive paperlaser diffractionABSTRACT Knowledge of droplet spectra generated by spray nozzle tips is important to ensure the quality of applications of plant protection products. However, there are different methods for this evaluation, which can cause difficulty in interpreting the results. This study aimed to evaluate the droplet spectra produced by the flat fan spray tip AD 11002 operated under different pressures and using different techniques and equipment. The volume median diameter (VMD), percentage of spray volume in droplets smaller than 100 µm diameter and relative spam (RS), considering pressures of 200, 300, and 400 kPa were determined using two direct measurement equipment (Spraytec and Shadow Sizer), based on laser diffraction and image analysis, respectively, and a measure based on indirect analysis, through the digitization of water-sensitive paper. Thus, the use of different analysis techniques led to variations of the analyzed parameters. Among the direct measurement equipment, a difference of up to 58% was observed in VMD. The use of water-sensitive paper to characterize droplet spectra must be carried out with great discretion because there is an underestimation of fine droplets. Pressure variations of 200 to 400 kPa did not influence VMD and RS.Associação Brasileira de Engenharia Agrícola2019-08-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-69162019000400476Engenharia Agrícola v.39 n.4 2019reponame:Engenharia Agrícolainstname:Associação Brasileira de Engenharia Agrícola (SBEA)instacron:SBEA10.1590/1809-4430-eng.agric.v39n4p476-481/2019info:eu-repo/semantics/openAccessCunha,João P. A. R. daReis,Elton F. dosAssunção,Heli H. T. deLandim,Thiago N.eng2019-08-30T00:00:00Zoai:scielo:S0100-69162019000400476Revistahttp://www.engenhariaagricola.org.br/ORGhttps://old.scielo.br/oai/scielo-oai.phprevistasbea@sbea.org.br||sbea@sbea.org.br1809-44300100-6916opendoar:2019-08-30T00:00Engenharia Agrícola - Associação Brasileira de Engenharia Agrícola (SBEA)false
dc.title.none.fl_str_mv EVALUATION OF DROPLET SPECTRA OF THE SPRAY TIP AD 11002 USING DIFFERENT TECHNIQUES
title EVALUATION OF DROPLET SPECTRA OF THE SPRAY TIP AD 11002 USING DIFFERENT TECHNIQUES
spellingShingle EVALUATION OF DROPLET SPECTRA OF THE SPRAY TIP AD 11002 USING DIFFERENT TECHNIQUES
Cunha,João P. A. R. da
application technology
droplet size
water-sensitive paper
laser diffraction
title_short EVALUATION OF DROPLET SPECTRA OF THE SPRAY TIP AD 11002 USING DIFFERENT TECHNIQUES
title_full EVALUATION OF DROPLET SPECTRA OF THE SPRAY TIP AD 11002 USING DIFFERENT TECHNIQUES
title_fullStr EVALUATION OF DROPLET SPECTRA OF THE SPRAY TIP AD 11002 USING DIFFERENT TECHNIQUES
title_full_unstemmed EVALUATION OF DROPLET SPECTRA OF THE SPRAY TIP AD 11002 USING DIFFERENT TECHNIQUES
title_sort EVALUATION OF DROPLET SPECTRA OF THE SPRAY TIP AD 11002 USING DIFFERENT TECHNIQUES
author Cunha,João P. A. R. da
author_facet Cunha,João P. A. R. da
Reis,Elton F. dos
Assunção,Heli H. T. de
Landim,Thiago N.
author_role author
author2 Reis,Elton F. dos
Assunção,Heli H. T. de
Landim,Thiago N.
author2_role author
author
author
dc.contributor.author.fl_str_mv Cunha,João P. A. R. da
Reis,Elton F. dos
Assunção,Heli H. T. de
Landim,Thiago N.
dc.subject.por.fl_str_mv application technology
droplet size
water-sensitive paper
laser diffraction
topic application technology
droplet size
water-sensitive paper
laser diffraction
description ABSTRACT Knowledge of droplet spectra generated by spray nozzle tips is important to ensure the quality of applications of plant protection products. However, there are different methods for this evaluation, which can cause difficulty in interpreting the results. This study aimed to evaluate the droplet spectra produced by the flat fan spray tip AD 11002 operated under different pressures and using different techniques and equipment. The volume median diameter (VMD), percentage of spray volume in droplets smaller than 100 µm diameter and relative spam (RS), considering pressures of 200, 300, and 400 kPa were determined using two direct measurement equipment (Spraytec and Shadow Sizer), based on laser diffraction and image analysis, respectively, and a measure based on indirect analysis, through the digitization of water-sensitive paper. Thus, the use of different analysis techniques led to variations of the analyzed parameters. Among the direct measurement equipment, a difference of up to 58% was observed in VMD. The use of water-sensitive paper to characterize droplet spectra must be carried out with great discretion because there is an underestimation of fine droplets. Pressure variations of 200 to 400 kPa did not influence VMD and RS.
publishDate 2019
dc.date.none.fl_str_mv 2019-08-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-69162019000400476
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-69162019000400476
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/1809-4430-eng.agric.v39n4p476-481/2019
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Associação Brasileira de Engenharia Agrícola
publisher.none.fl_str_mv Associação Brasileira de Engenharia Agrícola
dc.source.none.fl_str_mv Engenharia Agrícola v.39 n.4 2019
reponame:Engenharia Agrícola
instname:Associação Brasileira de Engenharia Agrícola (SBEA)
instacron:SBEA
instname_str Associação Brasileira de Engenharia Agrícola (SBEA)
instacron_str SBEA
institution SBEA
reponame_str Engenharia Agrícola
collection Engenharia Agrícola
repository.name.fl_str_mv Engenharia Agrícola - Associação Brasileira de Engenharia Agrícola (SBEA)
repository.mail.fl_str_mv revistasbea@sbea.org.br||sbea@sbea.org.br
_version_ 1752126274411692032