EVALUATION OF DROPLET SPECTRA OF THE SPRAY TIP AD 11002 USING DIFFERENT TECHNIQUES
Autor(a) principal: | |
---|---|
Data de Publicação: | 2019 |
Outros Autores: | , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Engenharia Agrícola |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-69162019000400476 |
Resumo: | ABSTRACT Knowledge of droplet spectra generated by spray nozzle tips is important to ensure the quality of applications of plant protection products. However, there are different methods for this evaluation, which can cause difficulty in interpreting the results. This study aimed to evaluate the droplet spectra produced by the flat fan spray tip AD 11002 operated under different pressures and using different techniques and equipment. The volume median diameter (VMD), percentage of spray volume in droplets smaller than 100 µm diameter and relative spam (RS), considering pressures of 200, 300, and 400 kPa were determined using two direct measurement equipment (Spraytec and Shadow Sizer), based on laser diffraction and image analysis, respectively, and a measure based on indirect analysis, through the digitization of water-sensitive paper. Thus, the use of different analysis techniques led to variations of the analyzed parameters. Among the direct measurement equipment, a difference of up to 58% was observed in VMD. The use of water-sensitive paper to characterize droplet spectra must be carried out with great discretion because there is an underestimation of fine droplets. Pressure variations of 200 to 400 kPa did not influence VMD and RS. |
id |
SBEA-1_0147d759b8a9c2d7690b076823f958ee |
---|---|
oai_identifier_str |
oai:scielo:S0100-69162019000400476 |
network_acronym_str |
SBEA-1 |
network_name_str |
Engenharia Agrícola |
repository_id_str |
|
spelling |
EVALUATION OF DROPLET SPECTRA OF THE SPRAY TIP AD 11002 USING DIFFERENT TECHNIQUESapplication technologydroplet sizewater-sensitive paperlaser diffractionABSTRACT Knowledge of droplet spectra generated by spray nozzle tips is important to ensure the quality of applications of plant protection products. However, there are different methods for this evaluation, which can cause difficulty in interpreting the results. This study aimed to evaluate the droplet spectra produced by the flat fan spray tip AD 11002 operated under different pressures and using different techniques and equipment. The volume median diameter (VMD), percentage of spray volume in droplets smaller than 100 µm diameter and relative spam (RS), considering pressures of 200, 300, and 400 kPa were determined using two direct measurement equipment (Spraytec and Shadow Sizer), based on laser diffraction and image analysis, respectively, and a measure based on indirect analysis, through the digitization of water-sensitive paper. Thus, the use of different analysis techniques led to variations of the analyzed parameters. Among the direct measurement equipment, a difference of up to 58% was observed in VMD. The use of water-sensitive paper to characterize droplet spectra must be carried out with great discretion because there is an underestimation of fine droplets. Pressure variations of 200 to 400 kPa did not influence VMD and RS.Associação Brasileira de Engenharia Agrícola2019-08-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-69162019000400476Engenharia Agrícola v.39 n.4 2019reponame:Engenharia Agrícolainstname:Associação Brasileira de Engenharia Agrícola (SBEA)instacron:SBEA10.1590/1809-4430-eng.agric.v39n4p476-481/2019info:eu-repo/semantics/openAccessCunha,João P. A. R. daReis,Elton F. dosAssunção,Heli H. T. deLandim,Thiago N.eng2019-08-30T00:00:00Zoai:scielo:S0100-69162019000400476Revistahttp://www.engenhariaagricola.org.br/ORGhttps://old.scielo.br/oai/scielo-oai.phprevistasbea@sbea.org.br||sbea@sbea.org.br1809-44300100-6916opendoar:2019-08-30T00:00Engenharia Agrícola - Associação Brasileira de Engenharia Agrícola (SBEA)false |
dc.title.none.fl_str_mv |
EVALUATION OF DROPLET SPECTRA OF THE SPRAY TIP AD 11002 USING DIFFERENT TECHNIQUES |
title |
EVALUATION OF DROPLET SPECTRA OF THE SPRAY TIP AD 11002 USING DIFFERENT TECHNIQUES |
spellingShingle |
EVALUATION OF DROPLET SPECTRA OF THE SPRAY TIP AD 11002 USING DIFFERENT TECHNIQUES Cunha,João P. A. R. da application technology droplet size water-sensitive paper laser diffraction |
title_short |
EVALUATION OF DROPLET SPECTRA OF THE SPRAY TIP AD 11002 USING DIFFERENT TECHNIQUES |
title_full |
EVALUATION OF DROPLET SPECTRA OF THE SPRAY TIP AD 11002 USING DIFFERENT TECHNIQUES |
title_fullStr |
EVALUATION OF DROPLET SPECTRA OF THE SPRAY TIP AD 11002 USING DIFFERENT TECHNIQUES |
title_full_unstemmed |
EVALUATION OF DROPLET SPECTRA OF THE SPRAY TIP AD 11002 USING DIFFERENT TECHNIQUES |
title_sort |
EVALUATION OF DROPLET SPECTRA OF THE SPRAY TIP AD 11002 USING DIFFERENT TECHNIQUES |
author |
Cunha,João P. A. R. da |
author_facet |
Cunha,João P. A. R. da Reis,Elton F. dos Assunção,Heli H. T. de Landim,Thiago N. |
author_role |
author |
author2 |
Reis,Elton F. dos Assunção,Heli H. T. de Landim,Thiago N. |
author2_role |
author author author |
dc.contributor.author.fl_str_mv |
Cunha,João P. A. R. da Reis,Elton F. dos Assunção,Heli H. T. de Landim,Thiago N. |
dc.subject.por.fl_str_mv |
application technology droplet size water-sensitive paper laser diffraction |
topic |
application technology droplet size water-sensitive paper laser diffraction |
description |
ABSTRACT Knowledge of droplet spectra generated by spray nozzle tips is important to ensure the quality of applications of plant protection products. However, there are different methods for this evaluation, which can cause difficulty in interpreting the results. This study aimed to evaluate the droplet spectra produced by the flat fan spray tip AD 11002 operated under different pressures and using different techniques and equipment. The volume median diameter (VMD), percentage of spray volume in droplets smaller than 100 µm diameter and relative spam (RS), considering pressures of 200, 300, and 400 kPa were determined using two direct measurement equipment (Spraytec and Shadow Sizer), based on laser diffraction and image analysis, respectively, and a measure based on indirect analysis, through the digitization of water-sensitive paper. Thus, the use of different analysis techniques led to variations of the analyzed parameters. Among the direct measurement equipment, a difference of up to 58% was observed in VMD. The use of water-sensitive paper to characterize droplet spectra must be carried out with great discretion because there is an underestimation of fine droplets. Pressure variations of 200 to 400 kPa did not influence VMD and RS. |
publishDate |
2019 |
dc.date.none.fl_str_mv |
2019-08-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-69162019000400476 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-69162019000400476 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/1809-4430-eng.agric.v39n4p476-481/2019 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Associação Brasileira de Engenharia Agrícola |
publisher.none.fl_str_mv |
Associação Brasileira de Engenharia Agrícola |
dc.source.none.fl_str_mv |
Engenharia Agrícola v.39 n.4 2019 reponame:Engenharia Agrícola instname:Associação Brasileira de Engenharia Agrícola (SBEA) instacron:SBEA |
instname_str |
Associação Brasileira de Engenharia Agrícola (SBEA) |
instacron_str |
SBEA |
institution |
SBEA |
reponame_str |
Engenharia Agrícola |
collection |
Engenharia Agrícola |
repository.name.fl_str_mv |
Engenharia Agrícola - Associação Brasileira de Engenharia Agrícola (SBEA) |
repository.mail.fl_str_mv |
revistasbea@sbea.org.br||sbea@sbea.org.br |
_version_ |
1752126274411692032 |