ELECTRONIC MONITORING SYSTEM FOR MEASURING HEART RATE AND SKIN TEMPERATURE IN SMALL RUMINANTS

Detalhes bibliográficos
Autor(a) principal: Costa,Daniel dos S.
Data de Publicação: 2018
Outros Autores: Turco,Silvia H. N., Ramos,Rodrigo P., Silva,Flaviane M. F. M., Freire,Murilo S.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Engenharia Agrícola
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-69162018000200166
Resumo: Abstract The electronic monitoring of physiological responses is essential for managing animal production systems considering market demands for animal welfare. The objective of this study was to design, build, and test an electronic monitoring system, with recording and wireless transmission capability, for measuring the heart rate and skin temperature in small ruminants. The system had two components: a mobile base unit, mounted on the animal under study, and a fixed base unit. Wireless communication between the mobile and fixed units was performed using a Xbee Series 2 radio frequency transceiver whereas data were recorded and transferred to a secure digital card in the mobile unit. The device was mounted in Santa Inês crossbred sheep using reference equipment while the animals were restrained in steel cages. Subsequently, the device was validated in free-living Dorper sheep in two collection periods (morning and afternoon). The results indicated that the monitoring system accurately measured physiological responses and efficiently recorded and transmitted data, particularly heart rate data. However, one of the limitations was low energy autonomy.
id SBEA-1_4b6c6e81482a4a175ab03a0b501a7615
oai_identifier_str oai:scielo:S0100-69162018000200166
network_acronym_str SBEA-1
network_name_str Engenharia Agrícola
repository_id_str
spelling ELECTRONIC MONITORING SYSTEM FOR MEASURING HEART RATE AND SKIN TEMPERATURE IN SMALL RUMINANTSembedded electronicsphysiological responsesprecision livestock farmingAbstract The electronic monitoring of physiological responses is essential for managing animal production systems considering market demands for animal welfare. The objective of this study was to design, build, and test an electronic monitoring system, with recording and wireless transmission capability, for measuring the heart rate and skin temperature in small ruminants. The system had two components: a mobile base unit, mounted on the animal under study, and a fixed base unit. Wireless communication between the mobile and fixed units was performed using a Xbee Series 2 radio frequency transceiver whereas data were recorded and transferred to a secure digital card in the mobile unit. The device was mounted in Santa Inês crossbred sheep using reference equipment while the animals were restrained in steel cages. Subsequently, the device was validated in free-living Dorper sheep in two collection periods (morning and afternoon). The results indicated that the monitoring system accurately measured physiological responses and efficiently recorded and transmitted data, particularly heart rate data. However, one of the limitations was low energy autonomy.Associação Brasileira de Engenharia Agrícola2018-04-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-69162018000200166Engenharia Agrícola v.38 n.2 2018reponame:Engenharia Agrícolainstname:Associação Brasileira de Engenharia Agrícola (SBEA)instacron:SBEA10.1590/1809-4430-eng.agric.v38n2p166-172/2018info:eu-repo/semantics/openAccessCosta,Daniel dos S.Turco,Silvia H. N.Ramos,Rodrigo P.Silva,Flaviane M. F. M.Freire,Murilo S.eng2018-05-29T00:00:00Zoai:scielo:S0100-69162018000200166Revistahttp://www.engenhariaagricola.org.br/ORGhttps://old.scielo.br/oai/scielo-oai.phprevistasbea@sbea.org.br||sbea@sbea.org.br1809-44300100-6916opendoar:2018-05-29T00:00Engenharia Agrícola - Associação Brasileira de Engenharia Agrícola (SBEA)false
dc.title.none.fl_str_mv ELECTRONIC MONITORING SYSTEM FOR MEASURING HEART RATE AND SKIN TEMPERATURE IN SMALL RUMINANTS
title ELECTRONIC MONITORING SYSTEM FOR MEASURING HEART RATE AND SKIN TEMPERATURE IN SMALL RUMINANTS
spellingShingle ELECTRONIC MONITORING SYSTEM FOR MEASURING HEART RATE AND SKIN TEMPERATURE IN SMALL RUMINANTS
Costa,Daniel dos S.
embedded electronics
physiological responses
precision livestock farming
title_short ELECTRONIC MONITORING SYSTEM FOR MEASURING HEART RATE AND SKIN TEMPERATURE IN SMALL RUMINANTS
title_full ELECTRONIC MONITORING SYSTEM FOR MEASURING HEART RATE AND SKIN TEMPERATURE IN SMALL RUMINANTS
title_fullStr ELECTRONIC MONITORING SYSTEM FOR MEASURING HEART RATE AND SKIN TEMPERATURE IN SMALL RUMINANTS
title_full_unstemmed ELECTRONIC MONITORING SYSTEM FOR MEASURING HEART RATE AND SKIN TEMPERATURE IN SMALL RUMINANTS
title_sort ELECTRONIC MONITORING SYSTEM FOR MEASURING HEART RATE AND SKIN TEMPERATURE IN SMALL RUMINANTS
author Costa,Daniel dos S.
author_facet Costa,Daniel dos S.
Turco,Silvia H. N.
Ramos,Rodrigo P.
Silva,Flaviane M. F. M.
Freire,Murilo S.
author_role author
author2 Turco,Silvia H. N.
Ramos,Rodrigo P.
Silva,Flaviane M. F. M.
Freire,Murilo S.
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Costa,Daniel dos S.
Turco,Silvia H. N.
Ramos,Rodrigo P.
Silva,Flaviane M. F. M.
Freire,Murilo S.
dc.subject.por.fl_str_mv embedded electronics
physiological responses
precision livestock farming
topic embedded electronics
physiological responses
precision livestock farming
description Abstract The electronic monitoring of physiological responses is essential for managing animal production systems considering market demands for animal welfare. The objective of this study was to design, build, and test an electronic monitoring system, with recording and wireless transmission capability, for measuring the heart rate and skin temperature in small ruminants. The system had two components: a mobile base unit, mounted on the animal under study, and a fixed base unit. Wireless communication between the mobile and fixed units was performed using a Xbee Series 2 radio frequency transceiver whereas data were recorded and transferred to a secure digital card in the mobile unit. The device was mounted in Santa Inês crossbred sheep using reference equipment while the animals were restrained in steel cages. Subsequently, the device was validated in free-living Dorper sheep in two collection periods (morning and afternoon). The results indicated that the monitoring system accurately measured physiological responses and efficiently recorded and transmitted data, particularly heart rate data. However, one of the limitations was low energy autonomy.
publishDate 2018
dc.date.none.fl_str_mv 2018-04-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-69162018000200166
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-69162018000200166
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/1809-4430-eng.agric.v38n2p166-172/2018
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Associação Brasileira de Engenharia Agrícola
publisher.none.fl_str_mv Associação Brasileira de Engenharia Agrícola
dc.source.none.fl_str_mv Engenharia Agrícola v.38 n.2 2018
reponame:Engenharia Agrícola
instname:Associação Brasileira de Engenharia Agrícola (SBEA)
instacron:SBEA
instname_str Associação Brasileira de Engenharia Agrícola (SBEA)
instacron_str SBEA
institution SBEA
reponame_str Engenharia Agrícola
collection Engenharia Agrícola
repository.name.fl_str_mv Engenharia Agrícola - Associação Brasileira de Engenharia Agrícola (SBEA)
repository.mail.fl_str_mv revistasbea@sbea.org.br||sbea@sbea.org.br
_version_ 1752126273651474432