Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-69162012000100009
Resumo: Quantifying soil evaporation is required on studies of soil water balance and applications aiming to improve water use efficiency by crops. The performance of a microlysimeter (ML) to measure soil evaporation under irrigation and non-irrigation was evaluated. The MLs were constructed using PVC tubes, with dimensions of 100 mm inner diameter, 150 mm depth and 2.5 mm wall thickness. Four MLs were uniformly distributed on the soil surface of two weighing lysimeters conducted under bare soil, previously installed at Iapar, in Londrina, PR, Brazil. The lysimeters had 1.4 m width, 1.9 m length and 1.3 m depth and were conducted with and without irrigation. Evaporation measurements by MLs (E ML) were compared with measurements by lysimeters (E L) during four different periods in the year. Differences between E ML and E L were small either for low or high atmospheric demand and also for either irrigated or non-irrigated conditions, which indicates that the ML tested here is suitable for measurement of soil evaporation.
id SBEA-1_4d4e7d56bbf57afe7182e430a8b127b7
oai_identifier_str oai:scielo:S0100-69162012000100009
network_acronym_str SBEA-1
network_name_str Engenharia Agrícola
repository_id_str
spelling Test of a microlysimeter for measurement of soil evaporationwater managementwater balancelysimeterssoil waterQuantifying soil evaporation is required on studies of soil water balance and applications aiming to improve water use efficiency by crops. The performance of a microlysimeter (ML) to measure soil evaporation under irrigation and non-irrigation was evaluated. The MLs were constructed using PVC tubes, with dimensions of 100 mm inner diameter, 150 mm depth and 2.5 mm wall thickness. Four MLs were uniformly distributed on the soil surface of two weighing lysimeters conducted under bare soil, previously installed at Iapar, in Londrina, PR, Brazil. The lysimeters had 1.4 m width, 1.9 m length and 1.3 m depth and were conducted with and without irrigation. Evaporation measurements by MLs (E ML) were compared with measurements by lysimeters (E L) during four different periods in the year. Differences between E ML and E L were small either for low or high atmospheric demand and also for either irrigated or non-irrigated conditions, which indicates that the ML tested here is suitable for measurement of soil evaporation.Associação Brasileira de Engenharia Agrícola2012-02-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-69162012000100009Engenharia Agrícola v.32 n.1 2012reponame:Engenharia Agrícolainstname:Associação Brasileira de Engenharia Agrícola (SBEA)instacron:SBEA10.1590/S0100-69162012000100009info:eu-repo/semantics/openAccessFlumignan,Danilton L.Faria,Rogério T. deLena,Bruno P.eng2012-04-18T00:00:00Zoai:scielo:S0100-69162012000100009Revistahttp://www.engenhariaagricola.org.br/ORGhttps://old.scielo.br/oai/scielo-oai.phprevistasbea@sbea.org.br||sbea@sbea.org.br1809-44300100-6916opendoar:2012-04-18T00:00Engenharia Agrícola - Associação Brasileira de Engenharia Agrícola (SBEA)false
dc.title.none.fl_str_mv Test of a microlysimeter for measurement of soil evaporation
title Test of a microlysimeter for measurement of soil evaporation
spellingShingle Test of a microlysimeter for measurement of soil evaporation
Flumignan,Danilton L.
water management
water balance
lysimeters
soil water
title_short Test of a microlysimeter for measurement of soil evaporation
title_full Test of a microlysimeter for measurement of soil evaporation
title_fullStr Test of a microlysimeter for measurement of soil evaporation
title_full_unstemmed Test of a microlysimeter for measurement of soil evaporation
title_sort Test of a microlysimeter for measurement of soil evaporation
author Flumignan,Danilton L.
author_facet Flumignan,Danilton L.
Faria,Rogério T. de
Lena,Bruno P.
author_role author
author2 Faria,Rogério T. de
Lena,Bruno P.
author2_role author
author
dc.contributor.author.fl_str_mv Flumignan,Danilton L.
Faria,Rogério T. de
Lena,Bruno P.
dc.subject.por.fl_str_mv water management
water balance
lysimeters
soil water
topic water management
water balance
lysimeters
soil water
description Quantifying soil evaporation is required on studies of soil water balance and applications aiming to improve water use efficiency by crops. The performance of a microlysimeter (ML) to measure soil evaporation under irrigation and non-irrigation was evaluated. The MLs were constructed using PVC tubes, with dimensions of 100 mm inner diameter, 150 mm depth and 2.5 mm wall thickness. Four MLs were uniformly distributed on the soil surface of two weighing lysimeters conducted under bare soil, previously installed at Iapar, in Londrina, PR, Brazil. The lysimeters had 1.4 m width, 1.9 m length and 1.3 m depth and were conducted with and without irrigation. Evaporation measurements by MLs (E ML) were compared with measurements by lysimeters (E L) during four different periods in the year. Differences between E ML and E L were small either for low or high atmospheric demand and also for either irrigated or non-irrigated conditions, which indicates that the ML tested here is suitable for measurement of soil evaporation.
publishDate 2012
dc.date.none.fl_str_mv 2012-02-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-69162012000100009
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-69162012000100009
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S0100-69162012000100009
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Associação Brasileira de Engenharia Agrícola
publisher.none.fl_str_mv Associação Brasileira de Engenharia Agrícola
dc.source.none.fl_str_mv Engenharia Agrícola v.32 n.1 2012
reponame:Engenharia Agrícola
instname:Associação Brasileira de Engenharia Agrícola (SBEA)
instacron:SBEA
instname_str Associação Brasileira de Engenharia Agrícola (SBEA)
instacron_str SBEA
institution SBEA
reponame_str Engenharia Agrícola
collection Engenharia Agrícola
repository.name.fl_str_mv Engenharia Agrícola - Associação Brasileira de Engenharia Agrícola (SBEA)
repository.mail.fl_str_mv revistasbea@sbea.org.br||sbea@sbea.org.br
_version_ 1752126270691344384