Resumo: | IntroductionNowadays Knee Osteoarthritis (KOA) affects a large percentage of the elderly, and one solution is to perform a Total Knee Arthroplasty (TKA). In this paper, one intends to study the gait and posture of these patients after the TKA, while walking with three assistive devices (ADs) (crutches, standard walker (SW) and rollator with forearm supports (RFS)).MethodsEleven patients were evaluated in 2 phases: 5 days and 15 days after surgery. This evaluation was conducted with two inertial sensors, one attached to the operated leg ankle, to measure spatiotemporal parameters, and the other at the sacrum, to measure posture and fall risk-related parameters. Multivariate analysis of variance (MANOVA) with repeated measures was performed to detect group differences.ResultsThe MANOVA results show that all spatiotemporal parameters are significantly different (p<0.05) between the two phases of study. So, time has a significant influence on such parameters. In relation to the ADs, one observes that there are statistical significant effects on all spatiotemporal parameters, except for swing duration and step length (p>0.05). The interaction between time and ADs only affects significantly the velocity (p<0.05). In terms of fall risk parameters, time only significantly affects the antero-posterior direction (p<0.05) and ADs affects significantly root mean square in medio-lateral direction (p<0.05). In terms of interaction between time and ADs, there are no statistical significant differences.ConclusionThis study concludes that depending on the state of recovery of the patient, different ADs should be prescribed. On the overall, standard walker is good to give stability to the patient and RFS allows the patient to present a gait pattern closer to a natural gait. |
id |
SBEB-1_12c5b1c1de2a0560d45d7662708bf4f1 |
---|---|
oai_identifier_str |
oai:scielo:S2446-47402015000300208 |
network_acronym_str |
SBEB-1 |
network_name_str |
Research on Biomedical Engineering (Online) |
repository_id_str |
|
spelling |
Evaluation of gait performance of knee osteoarthritis patients after total knee arthroplasty with different assistive devicesKnee osteoarthritisTotal knee arthroplastyAssistive devicesElderlyWalkersIntroductionNowadays Knee Osteoarthritis (KOA) affects a large percentage of the elderly, and one solution is to perform a Total Knee Arthroplasty (TKA). In this paper, one intends to study the gait and posture of these patients after the TKA, while walking with three assistive devices (ADs) (crutches, standard walker (SW) and rollator with forearm supports (RFS)).MethodsEleven patients were evaluated in 2 phases: 5 days and 15 days after surgery. This evaluation was conducted with two inertial sensors, one attached to the operated leg ankle, to measure spatiotemporal parameters, and the other at the sacrum, to measure posture and fall risk-related parameters. Multivariate analysis of variance (MANOVA) with repeated measures was performed to detect group differences.ResultsThe MANOVA results show that all spatiotemporal parameters are significantly different (p<0.05) between the two phases of study. So, time has a significant influence on such parameters. In relation to the ADs, one observes that there are statistical significant effects on all spatiotemporal parameters, except for swing duration and step length (p>0.05). The interaction between time and ADs only affects significantly the velocity (p<0.05). In terms of fall risk parameters, time only significantly affects the antero-posterior direction (p<0.05) and ADs affects significantly root mean square in medio-lateral direction (p<0.05). In terms of interaction between time and ADs, there are no statistical significant differences.ConclusionThis study concludes that depending on the state of recovery of the patient, different ADs should be prescribed. On the overall, standard walker is good to give stability to the patient and RFS allows the patient to present a gait pattern closer to a natural gait.Sociedade Brasileira de Engenharia Biomédica2015-09-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S2446-47402015000300208Research on Biomedical Engineering v.31 n.3 2015reponame:Research on Biomedical Engineering (Online)instname:Sociedade Brasileira de Engenharia Biomédica (SBEB)instacron:SBEB10.1590/2446-4740.0729info:eu-repo/semantics/openAccessTereso,AnaMartins,Maria ManuelSantos,Cristina Peixotoeng2015-10-20T00:00:00Zoai:scielo:S2446-47402015000300208Revistahttp://www.rbejournal.org/https://old.scielo.br/oai/scielo-oai.php||rbe@rbejournal.org2446-47402446-4732opendoar:2015-10-20T00:00Research on Biomedical Engineering (Online) - Sociedade Brasileira de Engenharia Biomédica (SBEB)false |
dc.title.none.fl_str_mv |
Evaluation of gait performance of knee osteoarthritis patients after total knee arthroplasty with different assistive devices |
title |
Evaluation of gait performance of knee osteoarthritis patients after total knee arthroplasty with different assistive devices |
spellingShingle |
Evaluation of gait performance of knee osteoarthritis patients after total knee arthroplasty with different assistive devices Tereso,Ana Knee osteoarthritis Total knee arthroplasty Assistive devices Elderly Walkers |
title_short |
Evaluation of gait performance of knee osteoarthritis patients after total knee arthroplasty with different assistive devices |
title_full |
Evaluation of gait performance of knee osteoarthritis patients after total knee arthroplasty with different assistive devices |
title_fullStr |
Evaluation of gait performance of knee osteoarthritis patients after total knee arthroplasty with different assistive devices |
title_full_unstemmed |
Evaluation of gait performance of knee osteoarthritis patients after total knee arthroplasty with different assistive devices |
title_sort |
Evaluation of gait performance of knee osteoarthritis patients after total knee arthroplasty with different assistive devices |
author |
Tereso,Ana |
author_facet |
Tereso,Ana Martins,Maria Manuel Santos,Cristina Peixoto |
author_role |
author |
author2 |
Martins,Maria Manuel Santos,Cristina Peixoto |
author2_role |
author author |
dc.contributor.author.fl_str_mv |
Tereso,Ana Martins,Maria Manuel Santos,Cristina Peixoto |
dc.subject.por.fl_str_mv |
Knee osteoarthritis Total knee arthroplasty Assistive devices Elderly Walkers |
topic |
Knee osteoarthritis Total knee arthroplasty Assistive devices Elderly Walkers |
description |
IntroductionNowadays Knee Osteoarthritis (KOA) affects a large percentage of the elderly, and one solution is to perform a Total Knee Arthroplasty (TKA). In this paper, one intends to study the gait and posture of these patients after the TKA, while walking with three assistive devices (ADs) (crutches, standard walker (SW) and rollator with forearm supports (RFS)).MethodsEleven patients were evaluated in 2 phases: 5 days and 15 days after surgery. This evaluation was conducted with two inertial sensors, one attached to the operated leg ankle, to measure spatiotemporal parameters, and the other at the sacrum, to measure posture and fall risk-related parameters. Multivariate analysis of variance (MANOVA) with repeated measures was performed to detect group differences.ResultsThe MANOVA results show that all spatiotemporal parameters are significantly different (p<0.05) between the two phases of study. So, time has a significant influence on such parameters. In relation to the ADs, one observes that there are statistical significant effects on all spatiotemporal parameters, except for swing duration and step length (p>0.05). The interaction between time and ADs only affects significantly the velocity (p<0.05). In terms of fall risk parameters, time only significantly affects the antero-posterior direction (p<0.05) and ADs affects significantly root mean square in medio-lateral direction (p<0.05). In terms of interaction between time and ADs, there are no statistical significant differences.ConclusionThis study concludes that depending on the state of recovery of the patient, different ADs should be prescribed. On the overall, standard walker is good to give stability to the patient and RFS allows the patient to present a gait pattern closer to a natural gait. |
publishDate |
2015 |
dc.date.none.fl_str_mv |
2015-09-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S2446-47402015000300208 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S2446-47402015000300208 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/2446-4740.0729 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira de Engenharia Biomédica |
publisher.none.fl_str_mv |
Sociedade Brasileira de Engenharia Biomédica |
dc.source.none.fl_str_mv |
Research on Biomedical Engineering v.31 n.3 2015 reponame:Research on Biomedical Engineering (Online) instname:Sociedade Brasileira de Engenharia Biomédica (SBEB) instacron:SBEB |
instname_str |
Sociedade Brasileira de Engenharia Biomédica (SBEB) |
instacron_str |
SBEB |
institution |
SBEB |
reponame_str |
Research on Biomedical Engineering (Online) |
collection |
Research on Biomedical Engineering (Online) |
repository.name.fl_str_mv |
Research on Biomedical Engineering (Online) - Sociedade Brasileira de Engenharia Biomédica (SBEB) |
repository.mail.fl_str_mv |
||rbe@rbejournal.org |
_version_ |
1752126288196272128 |