Rice detector: proposal of a novel objective response detection technique
Autor(a) principal: | |
---|---|
Data de Publicação: | 2013 |
Outros Autores: | , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Revista Brasileira de Engenharia Biomédica (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1517-31512013000400002 |
Resumo: | INTRODUCTION: The detection of the somatosensory response (SR) is an important tool for the neurophysiological evaluation in the intra and post-operative period of some vascular and spine surgeries. Particularly, the SR identification with a maximum false positive ratio by means of Objective Response Detection (ORD) techniques could lead to a less subjective procedure. In this work a novel ORD, the Rice Detector (RD), is presented and its theoretical critical value is obtained. METHODS: The probability of detection (PD) of RD is assessed for different numbers of eletroencephalographic (EEG) signal epochs (M = 30, 60, 120, 240) and signal-to-noise ratios (-20 to 10 dB, in steps of 1 dB) by means of simulation. The simulated PD curves (PDc) are compared with the theoretical ones and with the PDc of the Magnitude-Squared Coherence (MSC), a well-known ORD technique. The performance of RD and MSC are also compared for real EEG data. The comparison is based on the DP for estimates calculated with M = 30, 60, 120 and 240 epochs. RESULTS: The results showed that the simulated PDc follow the theoretical ones and both the MSC and RD present similar performance, with slight advantage for this latter at low M-values. However, for real data, no statistical significant difference (proportion test with alpha=0.05) was found between MSC and RD. CONCLUSION: Both techniques presented mean detection rates varying from 70% to 90%, even for intermediate M-value (120 epochs), and can be useful for evoked response detection applications. |
id |
SBEB-2_ef67b09a5a32b8fbec288b8febee1957 |
---|---|
oai_identifier_str |
oai:scielo:S1517-31512013000400002 |
network_acronym_str |
SBEB-2 |
network_name_str |
Revista Brasileira de Engenharia Biomédica (Online) |
repository_id_str |
|
spelling |
Rice detector: proposal of a novel objective response detection techniqueObjective response detectionRice distributionRice detectorMagnitude-squared coherenceEvoked potentialElectroencephalographyINTRODUCTION: The detection of the somatosensory response (SR) is an important tool for the neurophysiological evaluation in the intra and post-operative period of some vascular and spine surgeries. Particularly, the SR identification with a maximum false positive ratio by means of Objective Response Detection (ORD) techniques could lead to a less subjective procedure. In this work a novel ORD, the Rice Detector (RD), is presented and its theoretical critical value is obtained. METHODS: The probability of detection (PD) of RD is assessed for different numbers of eletroencephalographic (EEG) signal epochs (M = 30, 60, 120, 240) and signal-to-noise ratios (-20 to 10 dB, in steps of 1 dB) by means of simulation. The simulated PD curves (PDc) are compared with the theoretical ones and with the PDc of the Magnitude-Squared Coherence (MSC), a well-known ORD technique. The performance of RD and MSC are also compared for real EEG data. The comparison is based on the DP for estimates calculated with M = 30, 60, 120 and 240 epochs. RESULTS: The results showed that the simulated PDc follow the theoretical ones and both the MSC and RD present similar performance, with slight advantage for this latter at low M-values. However, for real data, no statistical significant difference (proportion test with alpha=0.05) was found between MSC and RD. CONCLUSION: Both techniques presented mean detection rates varying from 70% to 90%, even for intermediate M-value (120 epochs), and can be useful for evoked response detection applications.SBEB - Sociedade Brasileira de Engenharia Biomédica2013-12-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1517-31512013000400002Revista Brasileira de Engenharia Biomédica v.29 n.4 2013reponame:Revista Brasileira de Engenharia Biomédica (Online)instname:Sociedade Brasileira de Engenharia Biomédica (SBEB)instacron:SBEB10.4322/rbeb.2013.043info:eu-repo/semantics/openAccessFarina Júnior,Paulo DaniloMelges,Danilo BarbosaInfantosi,Antonio Fernando CatelliSá,Antonio Mauricio Ferreira Leite Miranda deeng2015-05-19T00:00:00Zoai:scielo:S1517-31512013000400002Revistahttp://www.scielo.br/rbebONGhttps://old.scielo.br/oai/scielo-oai.php||rbeb@rbeb.org.br1984-77421517-3151opendoar:2015-05-19T00:00Revista Brasileira de Engenharia Biomédica (Online) - Sociedade Brasileira de Engenharia Biomédica (SBEB)false |
dc.title.none.fl_str_mv |
Rice detector: proposal of a novel objective response detection technique |
title |
Rice detector: proposal of a novel objective response detection technique |
spellingShingle |
Rice detector: proposal of a novel objective response detection technique Farina Júnior,Paulo Danilo Objective response detection Rice distribution Rice detector Magnitude-squared coherence Evoked potential Electroencephalography |
title_short |
Rice detector: proposal of a novel objective response detection technique |
title_full |
Rice detector: proposal of a novel objective response detection technique |
title_fullStr |
Rice detector: proposal of a novel objective response detection technique |
title_full_unstemmed |
Rice detector: proposal of a novel objective response detection technique |
title_sort |
Rice detector: proposal of a novel objective response detection technique |
author |
Farina Júnior,Paulo Danilo |
author_facet |
Farina Júnior,Paulo Danilo Melges,Danilo Barbosa Infantosi,Antonio Fernando Catelli Sá,Antonio Mauricio Ferreira Leite Miranda de |
author_role |
author |
author2 |
Melges,Danilo Barbosa Infantosi,Antonio Fernando Catelli Sá,Antonio Mauricio Ferreira Leite Miranda de |
author2_role |
author author author |
dc.contributor.author.fl_str_mv |
Farina Júnior,Paulo Danilo Melges,Danilo Barbosa Infantosi,Antonio Fernando Catelli Sá,Antonio Mauricio Ferreira Leite Miranda de |
dc.subject.por.fl_str_mv |
Objective response detection Rice distribution Rice detector Magnitude-squared coherence Evoked potential Electroencephalography |
topic |
Objective response detection Rice distribution Rice detector Magnitude-squared coherence Evoked potential Electroencephalography |
description |
INTRODUCTION: The detection of the somatosensory response (SR) is an important tool for the neurophysiological evaluation in the intra and post-operative period of some vascular and spine surgeries. Particularly, the SR identification with a maximum false positive ratio by means of Objective Response Detection (ORD) techniques could lead to a less subjective procedure. In this work a novel ORD, the Rice Detector (RD), is presented and its theoretical critical value is obtained. METHODS: The probability of detection (PD) of RD is assessed for different numbers of eletroencephalographic (EEG) signal epochs (M = 30, 60, 120, 240) and signal-to-noise ratios (-20 to 10 dB, in steps of 1 dB) by means of simulation. The simulated PD curves (PDc) are compared with the theoretical ones and with the PDc of the Magnitude-Squared Coherence (MSC), a well-known ORD technique. The performance of RD and MSC are also compared for real EEG data. The comparison is based on the DP for estimates calculated with M = 30, 60, 120 and 240 epochs. RESULTS: The results showed that the simulated PDc follow the theoretical ones and both the MSC and RD present similar performance, with slight advantage for this latter at low M-values. However, for real data, no statistical significant difference (proportion test with alpha=0.05) was found between MSC and RD. CONCLUSION: Both techniques presented mean detection rates varying from 70% to 90%, even for intermediate M-value (120 epochs), and can be useful for evoked response detection applications. |
publishDate |
2013 |
dc.date.none.fl_str_mv |
2013-12-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1517-31512013000400002 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1517-31512013000400002 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.4322/rbeb.2013.043 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
SBEB - Sociedade Brasileira de Engenharia Biomédica |
publisher.none.fl_str_mv |
SBEB - Sociedade Brasileira de Engenharia Biomédica |
dc.source.none.fl_str_mv |
Revista Brasileira de Engenharia Biomédica v.29 n.4 2013 reponame:Revista Brasileira de Engenharia Biomédica (Online) instname:Sociedade Brasileira de Engenharia Biomédica (SBEB) instacron:SBEB |
instname_str |
Sociedade Brasileira de Engenharia Biomédica (SBEB) |
instacron_str |
SBEB |
institution |
SBEB |
reponame_str |
Revista Brasileira de Engenharia Biomédica (Online) |
collection |
Revista Brasileira de Engenharia Biomédica (Online) |
repository.name.fl_str_mv |
Revista Brasileira de Engenharia Biomédica (Online) - Sociedade Brasileira de Engenharia Biomédica (SBEB) |
repository.mail.fl_str_mv |
||rbeb@rbeb.org.br |
_version_ |
1754820915070238720 |