Flash glucose monitoring system in special situations

Detalhes bibliográficos
Autor(a) principal: Rigon,Fernanda Augustini
Data de Publicação: 2022
Outros Autores: Ronsoni,Marcelo Fernando, Vianna,André Gustavo Daher, Schiavon,Leonardo de Lucca, Hohl,Alexandre, Sande-Lee,Simone van de
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Arquivos de Endocrinologia e Metabolismo (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S2359-39972022000600883
Resumo: ABSTRACT The management of diabetes mellitus (DM) requires maintaining glycemic control, and patients must keep their blood glucose levels close to the normal range to reduce the risk of microvascular complications and cardiovascular events. While glycated hemoglobin (A1C) is currently the primary measure for glucose management and a key marker for long-term complications, it does not provide information on acute glycemic excursions and overall glycemic variability. These limitations may even be higher in some special situations, thereby compromising A1C accuracy, especially when wider glycemic variability is expected and/or when the glycemic goal is more stringent. To attain adequate glycemic control, continuous glucose monitoring (CGM) is more useful than self-monitoring of blood glucose (SMBG), as it is more convenient and provides a greater amount of data. Flash Glucose Monitoring (isCGM /FGM) is a widely accepted option of CGM for measuring interstitial glucose levels in individuals with DM. However, its application under special conditions, such as pregnancy, patients on hemodialysis, patients with cirrhosis, during hospitalization in the intensive care unit and during physical exercise has not yet been fully validated. This review addresses some of these specific situations in which hypoglycemia should be avoided, or in pregnancy, where strict glycemic control is essential, and the application of isCGM/FGM could alleviate the shortcomings associated with poor glucose control or high glycemic variability, thereby contributing to high-quality care.
id SBEM-1_17a599f16e47b6d893d359a4c875fbdc
oai_identifier_str oai:scielo:S2359-39972022000600883
network_acronym_str SBEM-1
network_name_str Arquivos de Endocrinologia e Metabolismo (Online)
repository_id_str
spelling Flash glucose monitoring system in special situationsDiabetes mellitusblood glucose self-monitoringliver cirrhosisrenal dialysispregnancyABSTRACT The management of diabetes mellitus (DM) requires maintaining glycemic control, and patients must keep their blood glucose levels close to the normal range to reduce the risk of microvascular complications and cardiovascular events. While glycated hemoglobin (A1C) is currently the primary measure for glucose management and a key marker for long-term complications, it does not provide information on acute glycemic excursions and overall glycemic variability. These limitations may even be higher in some special situations, thereby compromising A1C accuracy, especially when wider glycemic variability is expected and/or when the glycemic goal is more stringent. To attain adequate glycemic control, continuous glucose monitoring (CGM) is more useful than self-monitoring of blood glucose (SMBG), as it is more convenient and provides a greater amount of data. Flash Glucose Monitoring (isCGM /FGM) is a widely accepted option of CGM for measuring interstitial glucose levels in individuals with DM. However, its application under special conditions, such as pregnancy, patients on hemodialysis, patients with cirrhosis, during hospitalization in the intensive care unit and during physical exercise has not yet been fully validated. This review addresses some of these specific situations in which hypoglycemia should be avoided, or in pregnancy, where strict glycemic control is essential, and the application of isCGM/FGM could alleviate the shortcomings associated with poor glucose control or high glycemic variability, thereby contributing to high-quality care.Sociedade Brasileira de Endocrinologia e Metabologia2022-12-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S2359-39972022000600883Archives of Endocrinology and Metabolism v.66 n.6 2022reponame:Arquivos de Endocrinologia e Metabolismo (Online)instname:Sociedade Brasileira de Endocrinologia e Metabologia (SBEM)instacron:SBEM10.20945/2359-3997000000479info:eu-repo/semantics/openAccessRigon,Fernanda AugustiniRonsoni,Marcelo FernandoVianna,André Gustavo DaherSchiavon,Leonardo de LuccaHohl,AlexandreSande-Lee,Simone van deeng2022-11-24T00:00:00Zoai:scielo:S2359-39972022000600883Revistahttps://www.aem-sbem.com/https://old.scielo.br/oai/scielo-oai.php||aem.editorial.office@endocrino.org.br2359-42922359-3997opendoar:2022-11-24T00:00Arquivos de Endocrinologia e Metabolismo (Online) - Sociedade Brasileira de Endocrinologia e Metabologia (SBEM)false
dc.title.none.fl_str_mv Flash glucose monitoring system in special situations
title Flash glucose monitoring system in special situations
spellingShingle Flash glucose monitoring system in special situations
Rigon,Fernanda Augustini
Diabetes mellitus
blood glucose self-monitoring
liver cirrhosis
renal dialysis
pregnancy
title_short Flash glucose monitoring system in special situations
title_full Flash glucose monitoring system in special situations
title_fullStr Flash glucose monitoring system in special situations
title_full_unstemmed Flash glucose monitoring system in special situations
title_sort Flash glucose monitoring system in special situations
author Rigon,Fernanda Augustini
author_facet Rigon,Fernanda Augustini
Ronsoni,Marcelo Fernando
Vianna,André Gustavo Daher
Schiavon,Leonardo de Lucca
Hohl,Alexandre
Sande-Lee,Simone van de
author_role author
author2 Ronsoni,Marcelo Fernando
Vianna,André Gustavo Daher
Schiavon,Leonardo de Lucca
Hohl,Alexandre
Sande-Lee,Simone van de
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv Rigon,Fernanda Augustini
Ronsoni,Marcelo Fernando
Vianna,André Gustavo Daher
Schiavon,Leonardo de Lucca
Hohl,Alexandre
Sande-Lee,Simone van de
dc.subject.por.fl_str_mv Diabetes mellitus
blood glucose self-monitoring
liver cirrhosis
renal dialysis
pregnancy
topic Diabetes mellitus
blood glucose self-monitoring
liver cirrhosis
renal dialysis
pregnancy
description ABSTRACT The management of diabetes mellitus (DM) requires maintaining glycemic control, and patients must keep their blood glucose levels close to the normal range to reduce the risk of microvascular complications and cardiovascular events. While glycated hemoglobin (A1C) is currently the primary measure for glucose management and a key marker for long-term complications, it does not provide information on acute glycemic excursions and overall glycemic variability. These limitations may even be higher in some special situations, thereby compromising A1C accuracy, especially when wider glycemic variability is expected and/or when the glycemic goal is more stringent. To attain adequate glycemic control, continuous glucose monitoring (CGM) is more useful than self-monitoring of blood glucose (SMBG), as it is more convenient and provides a greater amount of data. Flash Glucose Monitoring (isCGM /FGM) is a widely accepted option of CGM for measuring interstitial glucose levels in individuals with DM. However, its application under special conditions, such as pregnancy, patients on hemodialysis, patients with cirrhosis, during hospitalization in the intensive care unit and during physical exercise has not yet been fully validated. This review addresses some of these specific situations in which hypoglycemia should be avoided, or in pregnancy, where strict glycemic control is essential, and the application of isCGM/FGM could alleviate the shortcomings associated with poor glucose control or high glycemic variability, thereby contributing to high-quality care.
publishDate 2022
dc.date.none.fl_str_mv 2022-12-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S2359-39972022000600883
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S2359-39972022000600883
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.20945/2359-3997000000479
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Endocrinologia e Metabologia
publisher.none.fl_str_mv Sociedade Brasileira de Endocrinologia e Metabologia
dc.source.none.fl_str_mv Archives of Endocrinology and Metabolism v.66 n.6 2022
reponame:Arquivos de Endocrinologia e Metabolismo (Online)
instname:Sociedade Brasileira de Endocrinologia e Metabologia (SBEM)
instacron:SBEM
instname_str Sociedade Brasileira de Endocrinologia e Metabologia (SBEM)
instacron_str SBEM
institution SBEM
reponame_str Arquivos de Endocrinologia e Metabolismo (Online)
collection Arquivos de Endocrinologia e Metabolismo (Online)
repository.name.fl_str_mv Arquivos de Endocrinologia e Metabolismo (Online) - Sociedade Brasileira de Endocrinologia e Metabologia (SBEM)
repository.mail.fl_str_mv ||aem.editorial.office@endocrino.org.br
_version_ 1752122518993371136