Increasing diagnostic effectiveness of thyroid nodule evaluation by implementation of cell block preparation in routine US-FNA analysis

Detalhes bibliográficos
Autor(a) principal: Cristo,Ana Patrícia de
Data de Publicação: 2016
Outros Autores: Goldstein,Heloísa Folgierini, Faccin,Carlo Sasso, Maia,Ana Luiza, Graudenz,Marcia Silveira
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Arquivos de Endocrinologia e Metabolismo (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S2359-39972016000400367
Resumo: ABSTRACT Objective Ultrasound-guided fine-needle aspiration (US-FNA) biopsy has proven to be an accurate and efficient tool in thyroid nodule evaluation. We evaluated whether cell block adds to the diagnostic accuracy of US-FNA. Subjects and methods Three hundred twenty-eight consecutive patients underwent US-FNA, cytology and cell block evaluation. Six slides were prepared for each patient and stained by Papanicolaou and Giemsa techniques. The residual hemorrhagic aspirate in the syringe and needle was fixed in 10% formalin and paraffin-embedded (cell block). The histological sections were examined as a complementary diagnostic tool to US-FNA. Results The study population comprised 89% females and the mean age was 57.4 ± 13.7 years. The mean nodule size was 2.3 ± 1.2 cm. US-FNA cytological results were as follows: Bethesda I, 17.1% (n = 56); Bethesda II, 61.6% (n = 202); Bethesda III, 9.5% (n = 31); Bethesda IV, 5.8% (n = 19); Bethesda V, 2.4% (n = 8), and Bethesda VI, 3.6% (n = 12). Cell blocks were obtained in 100% of cases and were considered diagnostic in 89.6%. Combined cytological and cell block (cyto-cell block) results were as follows: unsatisfactory, 4.3% (n = 14); benign, 72.6% (n = 238); indeterminate, 11.3% (n = 37); follicular lesion, 5.8% (n = 19); suspicious for malignancy, 2.4% (n = 8), and malignant, 3.6% (n = 12). The sensitivity and specificity for cyto-cell block was 100% and 90%, respectively, and the accuracy was 94%. Cyto-cell block analysis reduced the rate of unsatisfactory samples (p < 0.001). Conclusions The cyto-cell block interpretation improved the efficiency of US-FNA. This simple, fast and low-cost technique should be used as an adjunctive test in thyroid nodule evaluation. Arch Endocrinol Metab. 2016;60(4):367-73
id SBEM-1_5f08112fa045d5d1288be18e68a6965c
oai_identifier_str oai:scielo:S2359-39972016000400367
network_acronym_str SBEM-1
network_name_str Arquivos de Endocrinologia e Metabolismo (Online)
repository_id_str
spelling Increasing diagnostic effectiveness of thyroid nodule evaluation by implementation of cell block preparation in routine US-FNA analysisUltrasound-guided fine-needle aspiration (US-FNA)cell blockthyroid nodulethyroid cancerABSTRACT Objective Ultrasound-guided fine-needle aspiration (US-FNA) biopsy has proven to be an accurate and efficient tool in thyroid nodule evaluation. We evaluated whether cell block adds to the diagnostic accuracy of US-FNA. Subjects and methods Three hundred twenty-eight consecutive patients underwent US-FNA, cytology and cell block evaluation. Six slides were prepared for each patient and stained by Papanicolaou and Giemsa techniques. The residual hemorrhagic aspirate in the syringe and needle was fixed in 10% formalin and paraffin-embedded (cell block). The histological sections were examined as a complementary diagnostic tool to US-FNA. Results The study population comprised 89% females and the mean age was 57.4 ± 13.7 years. The mean nodule size was 2.3 ± 1.2 cm. US-FNA cytological results were as follows: Bethesda I, 17.1% (n = 56); Bethesda II, 61.6% (n = 202); Bethesda III, 9.5% (n = 31); Bethesda IV, 5.8% (n = 19); Bethesda V, 2.4% (n = 8), and Bethesda VI, 3.6% (n = 12). Cell blocks were obtained in 100% of cases and were considered diagnostic in 89.6%. Combined cytological and cell block (cyto-cell block) results were as follows: unsatisfactory, 4.3% (n = 14); benign, 72.6% (n = 238); indeterminate, 11.3% (n = 37); follicular lesion, 5.8% (n = 19); suspicious for malignancy, 2.4% (n = 8), and malignant, 3.6% (n = 12). The sensitivity and specificity for cyto-cell block was 100% and 90%, respectively, and the accuracy was 94%. Cyto-cell block analysis reduced the rate of unsatisfactory samples (p < 0.001). Conclusions The cyto-cell block interpretation improved the efficiency of US-FNA. This simple, fast and low-cost technique should be used as an adjunctive test in thyroid nodule evaluation. Arch Endocrinol Metab. 2016;60(4):367-73Sociedade Brasileira de Endocrinologia e Metabologia2016-08-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S2359-39972016000400367Archives of Endocrinology and Metabolism v.60 n.4 2016reponame:Arquivos de Endocrinologia e Metabolismo (Online)instname:Sociedade Brasileira de Endocrinologia e Metabologia (SBEM)instacron:SBEM10.1590/2359-3997000000180info:eu-repo/semantics/openAccessCristo,Ana Patrícia deGoldstein,Heloísa FolgieriniFaccin,Carlo SassoMaia,Ana LuizaGraudenz,Marcia Silveiraeng2016-08-12T00:00:00Zoai:scielo:S2359-39972016000400367Revistahttps://www.aem-sbem.com/https://old.scielo.br/oai/scielo-oai.php||aem.editorial.office@endocrino.org.br2359-42922359-3997opendoar:2016-08-12T00:00Arquivos de Endocrinologia e Metabolismo (Online) - Sociedade Brasileira de Endocrinologia e Metabologia (SBEM)false
dc.title.none.fl_str_mv Increasing diagnostic effectiveness of thyroid nodule evaluation by implementation of cell block preparation in routine US-FNA analysis
title Increasing diagnostic effectiveness of thyroid nodule evaluation by implementation of cell block preparation in routine US-FNA analysis
spellingShingle Increasing diagnostic effectiveness of thyroid nodule evaluation by implementation of cell block preparation in routine US-FNA analysis
Cristo,Ana Patrícia de
Ultrasound-guided fine-needle aspiration (US-FNA)
cell block
thyroid nodule
thyroid cancer
title_short Increasing diagnostic effectiveness of thyroid nodule evaluation by implementation of cell block preparation in routine US-FNA analysis
title_full Increasing diagnostic effectiveness of thyroid nodule evaluation by implementation of cell block preparation in routine US-FNA analysis
title_fullStr Increasing diagnostic effectiveness of thyroid nodule evaluation by implementation of cell block preparation in routine US-FNA analysis
title_full_unstemmed Increasing diagnostic effectiveness of thyroid nodule evaluation by implementation of cell block preparation in routine US-FNA analysis
title_sort Increasing diagnostic effectiveness of thyroid nodule evaluation by implementation of cell block preparation in routine US-FNA analysis
author Cristo,Ana Patrícia de
author_facet Cristo,Ana Patrícia de
Goldstein,Heloísa Folgierini
Faccin,Carlo Sasso
Maia,Ana Luiza
Graudenz,Marcia Silveira
author_role author
author2 Goldstein,Heloísa Folgierini
Faccin,Carlo Sasso
Maia,Ana Luiza
Graudenz,Marcia Silveira
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Cristo,Ana Patrícia de
Goldstein,Heloísa Folgierini
Faccin,Carlo Sasso
Maia,Ana Luiza
Graudenz,Marcia Silveira
dc.subject.por.fl_str_mv Ultrasound-guided fine-needle aspiration (US-FNA)
cell block
thyroid nodule
thyroid cancer
topic Ultrasound-guided fine-needle aspiration (US-FNA)
cell block
thyroid nodule
thyroid cancer
description ABSTRACT Objective Ultrasound-guided fine-needle aspiration (US-FNA) biopsy has proven to be an accurate and efficient tool in thyroid nodule evaluation. We evaluated whether cell block adds to the diagnostic accuracy of US-FNA. Subjects and methods Three hundred twenty-eight consecutive patients underwent US-FNA, cytology and cell block evaluation. Six slides were prepared for each patient and stained by Papanicolaou and Giemsa techniques. The residual hemorrhagic aspirate in the syringe and needle was fixed in 10% formalin and paraffin-embedded (cell block). The histological sections were examined as a complementary diagnostic tool to US-FNA. Results The study population comprised 89% females and the mean age was 57.4 ± 13.7 years. The mean nodule size was 2.3 ± 1.2 cm. US-FNA cytological results were as follows: Bethesda I, 17.1% (n = 56); Bethesda II, 61.6% (n = 202); Bethesda III, 9.5% (n = 31); Bethesda IV, 5.8% (n = 19); Bethesda V, 2.4% (n = 8), and Bethesda VI, 3.6% (n = 12). Cell blocks were obtained in 100% of cases and were considered diagnostic in 89.6%. Combined cytological and cell block (cyto-cell block) results were as follows: unsatisfactory, 4.3% (n = 14); benign, 72.6% (n = 238); indeterminate, 11.3% (n = 37); follicular lesion, 5.8% (n = 19); suspicious for malignancy, 2.4% (n = 8), and malignant, 3.6% (n = 12). The sensitivity and specificity for cyto-cell block was 100% and 90%, respectively, and the accuracy was 94%. Cyto-cell block analysis reduced the rate of unsatisfactory samples (p < 0.001). Conclusions The cyto-cell block interpretation improved the efficiency of US-FNA. This simple, fast and low-cost technique should be used as an adjunctive test in thyroid nodule evaluation. Arch Endocrinol Metab. 2016;60(4):367-73
publishDate 2016
dc.date.none.fl_str_mv 2016-08-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S2359-39972016000400367
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S2359-39972016000400367
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/2359-3997000000180
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Endocrinologia e Metabologia
publisher.none.fl_str_mv Sociedade Brasileira de Endocrinologia e Metabologia
dc.source.none.fl_str_mv Archives of Endocrinology and Metabolism v.60 n.4 2016
reponame:Arquivos de Endocrinologia e Metabolismo (Online)
instname:Sociedade Brasileira de Endocrinologia e Metabologia (SBEM)
instacron:SBEM
instname_str Sociedade Brasileira de Endocrinologia e Metabologia (SBEM)
instacron_str SBEM
institution SBEM
reponame_str Arquivos de Endocrinologia e Metabolismo (Online)
collection Arquivos de Endocrinologia e Metabolismo (Online)
repository.name.fl_str_mv Arquivos de Endocrinologia e Metabolismo (Online) - Sociedade Brasileira de Endocrinologia e Metabologia (SBEM)
repository.mail.fl_str_mv ||aem.editorial.office@endocrino.org.br
_version_ 1752122513970692096