Continuous glucose monitoring system: dawn period calibration does not change accuracy of the method

Detalhes bibliográficos
Autor(a) principal: Augusto,Gustavo A.
Data de Publicação: 2009
Outros Autores: Sousa,André G. P., Perazo,Marcela N. A., Correa-Giannella,Maria L. C., Nery,Marcia, Melo,Karla F. S. de
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Arquivos Brasileiros de Endocrinologia & Metabologia (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27302009000400006
Resumo: INTRODUCTION: Continuous glucose monitoring system is a valuable instrument to measure glycemic control, which uses a retrospective calibration based upon 3 to 4 capillary glucose meter values inserted by the patient each day. OBJECTIVE: We evaluated the interference of calibration during the dawn period in the system accuracy. METHODS: The monitoring data were retrospectively divided into two groups: with (Group A) or without (Group B) the dawn period calibration (between 1:00 and 5:00 AM). Accuracy of the method was expressed by relative absolute difference. RESULTS: Thirty-four continuous glucose monitoring data were evaluated comprising a total of 112 nights. A total of 289 paired readings were analyzed - 195 in Group A and 94 in Group B. We did not find a difference in relative absolute difference (RAD%) in any analyzed period of day by adding dawn calibration. CONCLUSIONS: These data suggest that dawn calibration does not alter accuracy of method.
id SBEM-2_e955844c43aad0de31160dc0b391ed2d
oai_identifier_str oai:scielo:S0004-27302009000400006
network_acronym_str SBEM-2
network_name_str Arquivos Brasileiros de Endocrinologia & Metabologia (Online)
repository_id_str
spelling Continuous glucose monitoring system: dawn period calibration does not change accuracy of the methodDiabetes mellitusglycemic controlhypoglycemiacontinuous monitoringINTRODUCTION: Continuous glucose monitoring system is a valuable instrument to measure glycemic control, which uses a retrospective calibration based upon 3 to 4 capillary glucose meter values inserted by the patient each day. OBJECTIVE: We evaluated the interference of calibration during the dawn period in the system accuracy. METHODS: The monitoring data were retrospectively divided into two groups: with (Group A) or without (Group B) the dawn period calibration (between 1:00 and 5:00 AM). Accuracy of the method was expressed by relative absolute difference. RESULTS: Thirty-four continuous glucose monitoring data were evaluated comprising a total of 112 nights. A total of 289 paired readings were analyzed - 195 in Group A and 94 in Group B. We did not find a difference in relative absolute difference (RAD%) in any analyzed period of day by adding dawn calibration. CONCLUSIONS: These data suggest that dawn calibration does not alter accuracy of method.Sociedade Brasileira de Endocrinologia e Metabologia2009-06-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27302009000400006Arquivos Brasileiros de Endocrinologia & Metabologia v.53 n.4 2009reponame:Arquivos Brasileiros de Endocrinologia & Metabologia (Online)instname:Sociedade Brasileira de Endocrinologia e Metabologia (SBEM)instacron:SBEM10.1590/S0004-27302009000400006info:eu-repo/semantics/openAccessAugusto,Gustavo A.Sousa,André G. P.Perazo,Marcela N. A.Correa-Giannella,Maria L. C.Nery,MarciaMelo,Karla F. S. deeng2009-07-22T00:00:00Zoai:scielo:S0004-27302009000400006Revistahttps://www.aem-sbem.com/ONGhttps://old.scielo.br/oai/scielo-oai.php||abem-editoria@endocrino.org.br1677-94870004-2730opendoar:2009-07-22T00:00Arquivos Brasileiros de Endocrinologia & Metabologia (Online) - Sociedade Brasileira de Endocrinologia e Metabologia (SBEM)false
dc.title.none.fl_str_mv Continuous glucose monitoring system: dawn period calibration does not change accuracy of the method
title Continuous glucose monitoring system: dawn period calibration does not change accuracy of the method
spellingShingle Continuous glucose monitoring system: dawn period calibration does not change accuracy of the method
Augusto,Gustavo A.
Diabetes mellitus
glycemic control
hypoglycemia
continuous monitoring
title_short Continuous glucose monitoring system: dawn period calibration does not change accuracy of the method
title_full Continuous glucose monitoring system: dawn period calibration does not change accuracy of the method
title_fullStr Continuous glucose monitoring system: dawn period calibration does not change accuracy of the method
title_full_unstemmed Continuous glucose monitoring system: dawn period calibration does not change accuracy of the method
title_sort Continuous glucose monitoring system: dawn period calibration does not change accuracy of the method
author Augusto,Gustavo A.
author_facet Augusto,Gustavo A.
Sousa,André G. P.
Perazo,Marcela N. A.
Correa-Giannella,Maria L. C.
Nery,Marcia
Melo,Karla F. S. de
author_role author
author2 Sousa,André G. P.
Perazo,Marcela N. A.
Correa-Giannella,Maria L. C.
Nery,Marcia
Melo,Karla F. S. de
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv Augusto,Gustavo A.
Sousa,André G. P.
Perazo,Marcela N. A.
Correa-Giannella,Maria L. C.
Nery,Marcia
Melo,Karla F. S. de
dc.subject.por.fl_str_mv Diabetes mellitus
glycemic control
hypoglycemia
continuous monitoring
topic Diabetes mellitus
glycemic control
hypoglycemia
continuous monitoring
description INTRODUCTION: Continuous glucose monitoring system is a valuable instrument to measure glycemic control, which uses a retrospective calibration based upon 3 to 4 capillary glucose meter values inserted by the patient each day. OBJECTIVE: We evaluated the interference of calibration during the dawn period in the system accuracy. METHODS: The monitoring data were retrospectively divided into two groups: with (Group A) or without (Group B) the dawn period calibration (between 1:00 and 5:00 AM). Accuracy of the method was expressed by relative absolute difference. RESULTS: Thirty-four continuous glucose monitoring data were evaluated comprising a total of 112 nights. A total of 289 paired readings were analyzed - 195 in Group A and 94 in Group B. We did not find a difference in relative absolute difference (RAD%) in any analyzed period of day by adding dawn calibration. CONCLUSIONS: These data suggest that dawn calibration does not alter accuracy of method.
publishDate 2009
dc.date.none.fl_str_mv 2009-06-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27302009000400006
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27302009000400006
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S0004-27302009000400006
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Endocrinologia e Metabologia
publisher.none.fl_str_mv Sociedade Brasileira de Endocrinologia e Metabologia
dc.source.none.fl_str_mv Arquivos Brasileiros de Endocrinologia & Metabologia v.53 n.4 2009
reponame:Arquivos Brasileiros de Endocrinologia & Metabologia (Online)
instname:Sociedade Brasileira de Endocrinologia e Metabologia (SBEM)
instacron:SBEM
instname_str Sociedade Brasileira de Endocrinologia e Metabologia (SBEM)
instacron_str SBEM
institution SBEM
reponame_str Arquivos Brasileiros de Endocrinologia & Metabologia (Online)
collection Arquivos Brasileiros de Endocrinologia & Metabologia (Online)
repository.name.fl_str_mv Arquivos Brasileiros de Endocrinologia & Metabologia (Online) - Sociedade Brasileira de Endocrinologia e Metabologia (SBEM)
repository.mail.fl_str_mv ||abem-editoria@endocrino.org.br
_version_ 1754734810506461184