Saline oscillator as a teaching experiment

Detalhes bibliográficos
Autor(a) principal: Lama,Lucas S. del
Data de Publicação: 2011
Outros Autores: Mulato,Marcelo
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Revista Brasileira de Ensino de Física (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-11172011000400010
Resumo: The saline oscillator consists of two aligned containers that are filled in by a pair of different solutions, exhibiting electrical potential oscillations when released. These oscillations occur due to a difference of mass density presented by the fluids and they cause varying ions flow, leading to electrical potential variations between both reservoirs. Many biological systems can be understood by this model. In this work, the saline oscillator was investigated using copper sulfate, CuSO4, and sodium chloride, NaCl, solutions, changing parameters as the diameter and length of the capillary, diameter of the internal compartment and amount of unwanted ions in the main reservoir (distillated and deionized water). The system is shown to be very useful in undergraduate teaching classes.
id SBF-1_aa95a6fa0a3f2a12042d605057067e7a
oai_identifier_str oai:scielo:S1806-11172011000400010
network_acronym_str SBF-1
network_name_str Revista Brasileira de Ensino de Física (Online)
repository_id_str
spelling Saline oscillator as a teaching experimentsaline oscillatornon-linear equationsfluid dynamicsThe saline oscillator consists of two aligned containers that are filled in by a pair of different solutions, exhibiting electrical potential oscillations when released. These oscillations occur due to a difference of mass density presented by the fluids and they cause varying ions flow, leading to electrical potential variations between both reservoirs. Many biological systems can be understood by this model. In this work, the saline oscillator was investigated using copper sulfate, CuSO4, and sodium chloride, NaCl, solutions, changing parameters as the diameter and length of the capillary, diameter of the internal compartment and amount of unwanted ions in the main reservoir (distillated and deionized water). The system is shown to be very useful in undergraduate teaching classes.Sociedade Brasileira de Física2011-12-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-11172011000400010Revista Brasileira de Ensino de Física v.33 n.4 2011reponame:Revista Brasileira de Ensino de Física (Online)instname:Sociedade Brasileira de Física (SBF)instacron:SBF10.1590/S1806-11172011000400010info:eu-repo/semantics/openAccessLama,Lucas S. delMulato,Marceloeng2012-03-02T00:00:00Zoai:scielo:S1806-11172011000400010Revistahttp://www.sbfisica.org.br/rbef/https://old.scielo.br/oai/scielo-oai.php||marcio@sbfisica.org.br1806-91261806-1117opendoar:2012-03-02T00:00Revista Brasileira de Ensino de Física (Online) - Sociedade Brasileira de Física (SBF)false
dc.title.none.fl_str_mv Saline oscillator as a teaching experiment
title Saline oscillator as a teaching experiment
spellingShingle Saline oscillator as a teaching experiment
Lama,Lucas S. del
saline oscillator
non-linear equations
fluid dynamics
title_short Saline oscillator as a teaching experiment
title_full Saline oscillator as a teaching experiment
title_fullStr Saline oscillator as a teaching experiment
title_full_unstemmed Saline oscillator as a teaching experiment
title_sort Saline oscillator as a teaching experiment
author Lama,Lucas S. del
author_facet Lama,Lucas S. del
Mulato,Marcelo
author_role author
author2 Mulato,Marcelo
author2_role author
dc.contributor.author.fl_str_mv Lama,Lucas S. del
Mulato,Marcelo
dc.subject.por.fl_str_mv saline oscillator
non-linear equations
fluid dynamics
topic saline oscillator
non-linear equations
fluid dynamics
description The saline oscillator consists of two aligned containers that are filled in by a pair of different solutions, exhibiting electrical potential oscillations when released. These oscillations occur due to a difference of mass density presented by the fluids and they cause varying ions flow, leading to electrical potential variations between both reservoirs. Many biological systems can be understood by this model. In this work, the saline oscillator was investigated using copper sulfate, CuSO4, and sodium chloride, NaCl, solutions, changing parameters as the diameter and length of the capillary, diameter of the internal compartment and amount of unwanted ions in the main reservoir (distillated and deionized water). The system is shown to be very useful in undergraduate teaching classes.
publishDate 2011
dc.date.none.fl_str_mv 2011-12-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-11172011000400010
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-11172011000400010
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S1806-11172011000400010
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Física
publisher.none.fl_str_mv Sociedade Brasileira de Física
dc.source.none.fl_str_mv Revista Brasileira de Ensino de Física v.33 n.4 2011
reponame:Revista Brasileira de Ensino de Física (Online)
instname:Sociedade Brasileira de Física (SBF)
instacron:SBF
instname_str Sociedade Brasileira de Física (SBF)
instacron_str SBF
institution SBF
reponame_str Revista Brasileira de Ensino de Física (Online)
collection Revista Brasileira de Ensino de Física (Online)
repository.name.fl_str_mv Revista Brasileira de Ensino de Física (Online) - Sociedade Brasileira de Física (SBF)
repository.mail.fl_str_mv ||marcio@sbfisica.org.br
_version_ 1752122421403451392