Thomson scattering diagnostic on the ETE tokamak: status and progress

Detalhes bibliográficos
Autor(a) principal: Berni,L. A.
Data de Publicação: 2004
Outros Autores: Del Bosco,E., Oliveira,R. M., Alonso,M. P.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Brazilian Journal of Physics
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-97332004000800012
Resumo: In order to measure the plasma temperature and density in the spherical tokamak ETE, a one-channel Thomson scattering system was implemented. During the upgrade of capacitor banks and optimization since the beginning of operation, the plasma pulse duration has increased from 1.5 ms up to 12 ms with plasma currents varying from 10 kA to 60 kA. During this phase, the electron temperature was increased from 20 eV to 160 eV with densities as high as 3.5×10(19) m-3. Presently, the Thomson scattering diagnostic is being upgraded based on the time-delay technique, that consists in usingfi bers of different lengths to transmit the scattered light signals to the same polychromator. This system will allow measurements of electron temperature and density profi les with ten spatial points per laser shot and per polychromator. This work describes in details the Thomson scattering system, presents a selection of results obtained by this system since the initial phase of operation, and shows details of the proposed upgrade of the Thomson scattering system.
id SBF-2_76af69af9f1aa7fc22502bd5b97f9597
oai_identifier_str oai:scielo:S0103-97332004000800012
network_acronym_str SBF-2
network_name_str Brazilian Journal of Physics
repository_id_str
spelling Thomson scattering diagnostic on the ETE tokamak: status and progressIn order to measure the plasma temperature and density in the spherical tokamak ETE, a one-channel Thomson scattering system was implemented. During the upgrade of capacitor banks and optimization since the beginning of operation, the plasma pulse duration has increased from 1.5 ms up to 12 ms with plasma currents varying from 10 kA to 60 kA. During this phase, the electron temperature was increased from 20 eV to 160 eV with densities as high as 3.5×10(19) m-3. Presently, the Thomson scattering diagnostic is being upgraded based on the time-delay technique, that consists in usingfi bers of different lengths to transmit the scattered light signals to the same polychromator. This system will allow measurements of electron temperature and density profi les with ten spatial points per laser shot and per polychromator. This work describes in details the Thomson scattering system, presents a selection of results obtained by this system since the initial phase of operation, and shows details of the proposed upgrade of the Thomson scattering system.Sociedade Brasileira de Física2004-12-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-97332004000800012Brazilian Journal of Physics v.34 n.4b 2004reponame:Brazilian Journal of Physicsinstname:Sociedade Brasileira de Física (SBF)instacron:SBF10.1590/S0103-97332004000800012info:eu-repo/semantics/openAccessBerni,L. A.Del Bosco,E.Oliveira,R. M.Alonso,M. P.eng2005-03-01T00:00:00Zoai:scielo:S0103-97332004000800012Revistahttp://www.sbfisica.org.br/v1/home/index.php/pt/ONGhttps://old.scielo.br/oai/scielo-oai.phpsbfisica@sbfisica.org.br||sbfisica@sbfisica.org.br1678-44480103-9733opendoar:2005-03-01T00:00Brazilian Journal of Physics - Sociedade Brasileira de Física (SBF)false
dc.title.none.fl_str_mv Thomson scattering diagnostic on the ETE tokamak: status and progress
title Thomson scattering diagnostic on the ETE tokamak: status and progress
spellingShingle Thomson scattering diagnostic on the ETE tokamak: status and progress
Berni,L. A.
title_short Thomson scattering diagnostic on the ETE tokamak: status and progress
title_full Thomson scattering diagnostic on the ETE tokamak: status and progress
title_fullStr Thomson scattering diagnostic on the ETE tokamak: status and progress
title_full_unstemmed Thomson scattering diagnostic on the ETE tokamak: status and progress
title_sort Thomson scattering diagnostic on the ETE tokamak: status and progress
author Berni,L. A.
author_facet Berni,L. A.
Del Bosco,E.
Oliveira,R. M.
Alonso,M. P.
author_role author
author2 Del Bosco,E.
Oliveira,R. M.
Alonso,M. P.
author2_role author
author
author
dc.contributor.author.fl_str_mv Berni,L. A.
Del Bosco,E.
Oliveira,R. M.
Alonso,M. P.
description In order to measure the plasma temperature and density in the spherical tokamak ETE, a one-channel Thomson scattering system was implemented. During the upgrade of capacitor banks and optimization since the beginning of operation, the plasma pulse duration has increased from 1.5 ms up to 12 ms with plasma currents varying from 10 kA to 60 kA. During this phase, the electron temperature was increased from 20 eV to 160 eV with densities as high as 3.5×10(19) m-3. Presently, the Thomson scattering diagnostic is being upgraded based on the time-delay technique, that consists in usingfi bers of different lengths to transmit the scattered light signals to the same polychromator. This system will allow measurements of electron temperature and density profi les with ten spatial points per laser shot and per polychromator. This work describes in details the Thomson scattering system, presents a selection of results obtained by this system since the initial phase of operation, and shows details of the proposed upgrade of the Thomson scattering system.
publishDate 2004
dc.date.none.fl_str_mv 2004-12-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-97332004000800012
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-97332004000800012
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S0103-97332004000800012
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Física
publisher.none.fl_str_mv Sociedade Brasileira de Física
dc.source.none.fl_str_mv Brazilian Journal of Physics v.34 n.4b 2004
reponame:Brazilian Journal of Physics
instname:Sociedade Brasileira de Física (SBF)
instacron:SBF
instname_str Sociedade Brasileira de Física (SBF)
instacron_str SBF
institution SBF
reponame_str Brazilian Journal of Physics
collection Brazilian Journal of Physics
repository.name.fl_str_mv Brazilian Journal of Physics - Sociedade Brasileira de Física (SBF)
repository.mail.fl_str_mv sbfisica@sbfisica.org.br||sbfisica@sbfisica.org.br
_version_ 1754734861594132480