MRI relaxometry: methods and applications
Autor(a) principal: | |
---|---|
Data de Publicação: | 2006 |
Outros Autores: | , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Brazilian Journal of Physics |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-97332006000100005 |
Resumo: | Aspects of magnetic resonance relaxation measurements in human tissues are discussed. The influence of pulse sequences and parameters are compared and analyzed for different tissues. By controlling the acquisition parameters and data fitting the relaxation rate can be useful in several clinical situations. The influence of repetition and echo time, predicted in sequences of signal acquisition, on measurement of transversal relaxation time (T2) was evaluate using simulated MRI signal. |
id |
SBF-2_8670dcc698f9f3f1324fbf3c93b1c50c |
---|---|
oai_identifier_str |
oai:scielo:S0103-97332006000100005 |
network_acronym_str |
SBF-2 |
network_name_str |
Brazilian Journal of Physics |
repository_id_str |
|
spelling |
MRI relaxometry: methods and applicationsMagnetic resonance imagingMRIAspects of magnetic resonance relaxation measurements in human tissues are discussed. The influence of pulse sequences and parameters are compared and analyzed for different tissues. By controlling the acquisition parameters and data fitting the relaxation rate can be useful in several clinical situations. The influence of repetition and echo time, predicted in sequences of signal acquisition, on measurement of transversal relaxation time (T2) was evaluate using simulated MRI signal.Sociedade Brasileira de Física2006-03-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-97332006000100005Brazilian Journal of Physics v.36 n.1a 2006reponame:Brazilian Journal of Physicsinstname:Sociedade Brasileira de Física (SBF)instacron:SBF10.1590/S0103-97332006000100005info:eu-repo/semantics/openAccessCarneiro,A. A. O.Vilela,G. R.Araujo,D. B. deBaffa,O.eng2006-04-03T00:00:00Zoai:scielo:S0103-97332006000100005Revistahttp://www.sbfisica.org.br/v1/home/index.php/pt/ONGhttps://old.scielo.br/oai/scielo-oai.phpsbfisica@sbfisica.org.br||sbfisica@sbfisica.org.br1678-44480103-9733opendoar:2006-04-03T00:00Brazilian Journal of Physics - Sociedade Brasileira de Física (SBF)false |
dc.title.none.fl_str_mv |
MRI relaxometry: methods and applications |
title |
MRI relaxometry: methods and applications |
spellingShingle |
MRI relaxometry: methods and applications Carneiro,A. A. O. Magnetic resonance imaging MRI |
title_short |
MRI relaxometry: methods and applications |
title_full |
MRI relaxometry: methods and applications |
title_fullStr |
MRI relaxometry: methods and applications |
title_full_unstemmed |
MRI relaxometry: methods and applications |
title_sort |
MRI relaxometry: methods and applications |
author |
Carneiro,A. A. O. |
author_facet |
Carneiro,A. A. O. Vilela,G. R. Araujo,D. B. de Baffa,O. |
author_role |
author |
author2 |
Vilela,G. R. Araujo,D. B. de Baffa,O. |
author2_role |
author author author |
dc.contributor.author.fl_str_mv |
Carneiro,A. A. O. Vilela,G. R. Araujo,D. B. de Baffa,O. |
dc.subject.por.fl_str_mv |
Magnetic resonance imaging MRI |
topic |
Magnetic resonance imaging MRI |
description |
Aspects of magnetic resonance relaxation measurements in human tissues are discussed. The influence of pulse sequences and parameters are compared and analyzed for different tissues. By controlling the acquisition parameters and data fitting the relaxation rate can be useful in several clinical situations. The influence of repetition and echo time, predicted in sequences of signal acquisition, on measurement of transversal relaxation time (T2) was evaluate using simulated MRI signal. |
publishDate |
2006 |
dc.date.none.fl_str_mv |
2006-03-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-97332006000100005 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-97332006000100005 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/S0103-97332006000100005 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira de Física |
publisher.none.fl_str_mv |
Sociedade Brasileira de Física |
dc.source.none.fl_str_mv |
Brazilian Journal of Physics v.36 n.1a 2006 reponame:Brazilian Journal of Physics instname:Sociedade Brasileira de Física (SBF) instacron:SBF |
instname_str |
Sociedade Brasileira de Física (SBF) |
instacron_str |
SBF |
institution |
SBF |
reponame_str |
Brazilian Journal of Physics |
collection |
Brazilian Journal of Physics |
repository.name.fl_str_mv |
Brazilian Journal of Physics - Sociedade Brasileira de Física (SBF) |
repository.mail.fl_str_mv |
sbfisica@sbfisica.org.br||sbfisica@sbfisica.org.br |
_version_ |
1754734862628028416 |