Texto Completo: https://ggaging.com/details/71
Resumo: <p><b>INTRODUCTION:</b> Manual tracing is an effective method to measure hippocampal volume. OsiriX<sup>TM</sup> is a Digital Imaging and Communications in Medicine (DICOM) viewer with an intuitive user interface that has been widely used by radiologists and other specialists in their daily practice.<br> <b>OBJECTIVE:</b> To describe OsiriX<sup>TM</sup>, a tool for in office manual measurement of hippocampal volume.<br> <b>METHODS:</b> The open-source OsiriX<sup>TM</sup> viewer was used with three dimensions (3D) T1 weighted spoiled gradient recalled echo (SPGR) sequence images, with 1 mm slice thickness and 0.1mm gap (voxel size 1 mm<sup>3</sup>). Magnetic Resonance Imagings (MRI) were obtained on a 1.5 T system. The entire procedure lasted less than 15 minutes for each hippocampus.<br> <b>CONCLUSION:</b> OsiriX<sup>TM</sup> viewer is a feasible tool for in office manual hippocampal measurement. There is no standard hippocampal volume for Alzheimer's disease, thus comparison could be regarded as the rate of hippocampal atrophy over time, correlated with clinical evaluation and cognitive tests.</p>
id SBGG_b47a19e6c402f00748dcf2eb317fd0b4
oai_identifier_str oai:ggaging.com:71
network_acronym_str SBGG
network_name_str Geriatrics, Gerontology and Aging (Online)
repository_id_str
spelling Osirix<sup>TM</sup> as a feasible tool for in office manual hippocampal volumetry in the elderly: a technical notehippocampus magnetic resonance imaging Alzheimer disease.<p><b>INTRODUCTION:</b> Manual tracing is an effective method to measure hippocampal volume. OsiriX<sup>TM</sup> is a Digital Imaging and Communications in Medicine (DICOM) viewer with an intuitive user interface that has been widely used by radiologists and other specialists in their daily practice.<br> <b>OBJECTIVE:</b> To describe OsiriX<sup>TM</sup>, a tool for in office manual measurement of hippocampal volume.<br> <b>METHODS:</b> The open-source OsiriX<sup>TM</sup> viewer was used with three dimensions (3D) T1 weighted spoiled gradient recalled echo (SPGR) sequence images, with 1 mm slice thickness and 0.1mm gap (voxel size 1 mm<sup>3</sup>). Magnetic Resonance Imagings (MRI) were obtained on a 1.5 T system. The entire procedure lasted less than 15 minutes for each hippocampus.<br> <b>CONCLUSION:</b> OsiriX<sup>TM</sup> viewer is a feasible tool for in office manual hippocampal measurement. There is no standard hippocampal volume for Alzheimer's disease, thus comparison could be regarded as the rate of hippocampal atrophy over time, correlated with clinical evaluation and cognitive tests.</p>Sociedade Brasileira de Geriatria e Gerontologia2016-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttps://ggaging.com/details/71Geriatrics, Gerontology and Aging v.10 n.1 2016reponame:Geriatrics, Gerontology and Aging (Online)instname:Sociedade Brasileira de Geriatria e Gerontologiainstacron:SBGGinfo:eu-repo/semantics/openAccess Louzada,Luciana Lilian Morato,Tiago Nóbrega Almeida,Rosimara Eva Ferreira Camargos,Einstein Francisco Nóbrega,Otávio Toledo Farage,Lucianoeng2016-01-01T00:00:00Zoai:ggaging.com:71Revistahttp://sbgg.org.br/publicacoes-cientificas/revista-geriatria-gerontologia/ONGhttps://old.scielo.br/oai/scielo-oai.phpexecutiveditors@ggaging.com||nacional@sbgg.org.br2447-21232447-2115opendoar:2016-01-01T00:00Geriatrics, Gerontology and Aging (Online) - Sociedade Brasileira de Geriatria e Gerontologiafalse
dc.title.none.fl_str_mv Osirix<sup>TM</sup> as a feasible tool for in office manual hippocampal volumetry in the elderly: a technical note
title Osirix<sup>TM</sup> as a feasible tool for in office manual hippocampal volumetry in the elderly: a technical note
spellingShingle Osirix<sup>TM</sup> as a feasible tool for in office manual hippocampal volumetry in the elderly: a technical note
Louzada,Luciana Lilian
hippocampus
magnetic resonance imaging
Alzheimer disease.
title_short Osirix<sup>TM</sup> as a feasible tool for in office manual hippocampal volumetry in the elderly: a technical note
title_full Osirix<sup>TM</sup> as a feasible tool for in office manual hippocampal volumetry in the elderly: a technical note
title_fullStr Osirix<sup>TM</sup> as a feasible tool for in office manual hippocampal volumetry in the elderly: a technical note
title_full_unstemmed Osirix<sup>TM</sup> as a feasible tool for in office manual hippocampal volumetry in the elderly: a technical note
title_sort Osirix<sup>TM</sup> as a feasible tool for in office manual hippocampal volumetry in the elderly: a technical note
author Louzada,Luciana Lilian
author_facet Louzada,Luciana Lilian
Morato,Tiago Nóbrega
Almeida,Rosimara Eva Ferreira
Camargos,Einstein Francisco
Nóbrega,Otávio Toledo
Farage,Luciano
author_role author
author2 Morato,Tiago Nóbrega
Almeida,Rosimara Eva Ferreira
Camargos,Einstein Francisco
Nóbrega,Otávio Toledo
Farage,Luciano
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv Louzada,Luciana Lilian
Morato,Tiago Nóbrega
Almeida,Rosimara Eva Ferreira
Camargos,Einstein Francisco
Nóbrega,Otávio Toledo
Farage,Luciano
dc.subject.por.fl_str_mv hippocampus
magnetic resonance imaging
Alzheimer disease.
topic hippocampus
magnetic resonance imaging
Alzheimer disease.
description <p><b>INTRODUCTION:</b> Manual tracing is an effective method to measure hippocampal volume. OsiriX<sup>TM</sup> is a Digital Imaging and Communications in Medicine (DICOM) viewer with an intuitive user interface that has been widely used by radiologists and other specialists in their daily practice.<br> <b>OBJECTIVE:</b> To describe OsiriX<sup>TM</sup>, a tool for in office manual measurement of hippocampal volume.<br> <b>METHODS:</b> The open-source OsiriX<sup>TM</sup> viewer was used with three dimensions (3D) T1 weighted spoiled gradient recalled echo (SPGR) sequence images, with 1 mm slice thickness and 0.1mm gap (voxel size 1 mm<sup>3</sup>). Magnetic Resonance Imagings (MRI) were obtained on a 1.5 T system. The entire procedure lasted less than 15 minutes for each hippocampus.<br> <b>CONCLUSION:</b> OsiriX<sup>TM</sup> viewer is a feasible tool for in office manual hippocampal measurement. There is no standard hippocampal volume for Alzheimer's disease, thus comparison could be regarded as the rate of hippocampal atrophy over time, correlated with clinical evaluation and cognitive tests.</p>
publishDate 2016
dc.date.none.fl_str_mv 2016-01-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://ggaging.com/details/71
url https://ggaging.com/details/71
dc.language.iso.fl_str_mv eng
language eng
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Geriatria e Gerontologia
publisher.none.fl_str_mv Sociedade Brasileira de Geriatria e Gerontologia
dc.source.none.fl_str_mv Geriatrics, Gerontology and Aging v.10 n.1 2016
reponame:Geriatrics, Gerontology and Aging (Online)
instname:Sociedade Brasileira de Geriatria e Gerontologia
instacron:SBGG
instname_str Sociedade Brasileira de Geriatria e Gerontologia
instacron_str SBGG
institution SBGG
reponame_str Geriatrics, Gerontology and Aging (Online)
collection Geriatrics, Gerontology and Aging (Online)
repository.name.fl_str_mv Geriatrics, Gerontology and Aging (Online) - Sociedade Brasileira de Geriatria e Gerontologia
repository.mail.fl_str_mv executiveditors@ggaging.com||nacional@sbgg.org.br
_version_ 1797174500795613184