Resumo: ABSTRACT Introduction When a person is in a standing position, the plantar flexor muscles are involved in most static and dynamic body movements. Objectives The aim of this study was to investigate the trial to trial and factorial reliability of measuring the contractile characteristics of PF muscles using a simple novel field test. Methods The sample consisted of 452 healthy subjects, 120 male and 332 female. The research was conducted by means of the trial to trial testing method, using isometric dynamometry performed in field conditions. ANOVA was used to estimate the differences among the trials, Cronbach’s alpha and interclass correlation to estimate the correlations among the trials, and principal component analysis to evaluate the contribution of each trial to overall variability. Results The main findings of this study are that trials differed significantly (p<0.000) for maximal force (Fmax) and maximal rate of force development (RFDmax), indicating that the three procedural trials were necessary. The trials were highly correlated (Fmax, RFDmax, r>0.9), proving that measuring was reliable, and the factorial analysis separated the second and third trials, the second trial accounting for most of the total variability. Conclusions The simple novel field test for the measurement of plantar flexor contractile characteristics recommended by this study proved to be as highly reliable as laboratory testing, but was easy to perform in conditions outside of scientific or diagnostic institutions, which greatly facilitates the work of scientists, coaches and professionals. Level of Evidence II; Diagnostic Studies – Investigating a diagnostics test.
id SBMEE-1_c648686763644d45c256918779ad16dd
oai_identifier_str oai:scielo:S1517-86922021000100098
network_acronym_str SBMEE-1
network_name_str Revista brasileira de medicina do esporte (Online)
repository_id_str
spelling RELIABILITY OF A SIMPLE NOVEL FIELD TEST FOR THE MEASUREMENT OF PLANTAR FLEXOR MUSCLE STRENGTHMuscle strengthDynamometerGastrocnemiusSoleusABSTRACT Introduction When a person is in a standing position, the plantar flexor muscles are involved in most static and dynamic body movements. Objectives The aim of this study was to investigate the trial to trial and factorial reliability of measuring the contractile characteristics of PF muscles using a simple novel field test. Methods The sample consisted of 452 healthy subjects, 120 male and 332 female. The research was conducted by means of the trial to trial testing method, using isometric dynamometry performed in field conditions. ANOVA was used to estimate the differences among the trials, Cronbach’s alpha and interclass correlation to estimate the correlations among the trials, and principal component analysis to evaluate the contribution of each trial to overall variability. Results The main findings of this study are that trials differed significantly (p<0.000) for maximal force (Fmax) and maximal rate of force development (RFDmax), indicating that the three procedural trials were necessary. The trials were highly correlated (Fmax, RFDmax, r>0.9), proving that measuring was reliable, and the factorial analysis separated the second and third trials, the second trial accounting for most of the total variability. Conclusions The simple novel field test for the measurement of plantar flexor contractile characteristics recommended by this study proved to be as highly reliable as laboratory testing, but was easy to perform in conditions outside of scientific or diagnostic institutions, which greatly facilitates the work of scientists, coaches and professionals. Level of Evidence II; Diagnostic Studies – Investigating a diagnostics test.Sociedade Brasileira de Medicina do Exercício e do Esporte2021-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1517-86922021000100098Revista Brasileira de Medicina do Esporte v.27 n.1 2021reponame:Revista brasileira de medicina do esporte (Online)instname:Sociedade Brasileira de Medicina do Exercício e do Esporte (SBMEE)instacron:SBMEE10.1590/1517-8692202127012019_0002info:eu-repo/semantics/openAccessMajstorović,NikolaNešić,GoranGrbić,VladimirSavić,ZoranŽivković,MilenaAničić,ZdravkoMarković,StefanDopsaj,Milivojeng2021-03-04T00:00:00Zoai:scielo:S1517-86922021000100098Revistahttp://www.scielo.br/rbmeONGhttps://old.scielo.br/oai/scielo-oai.php||revista@medicinadoesporte.org.br1806-99401517-8692opendoar:2021-03-04T00:00Revista brasileira de medicina do esporte (Online) - Sociedade Brasileira de Medicina do Exercício e do Esporte (SBMEE)false
dc.title.none.fl_str_mv RELIABILITY OF A SIMPLE NOVEL FIELD TEST FOR THE MEASUREMENT OF PLANTAR FLEXOR MUSCLE STRENGTH
title RELIABILITY OF A SIMPLE NOVEL FIELD TEST FOR THE MEASUREMENT OF PLANTAR FLEXOR MUSCLE STRENGTH
spellingShingle RELIABILITY OF A SIMPLE NOVEL FIELD TEST FOR THE MEASUREMENT OF PLANTAR FLEXOR MUSCLE STRENGTH
Majstorović,Nikola
Muscle strength
Dynamometer
Gastrocnemius
Soleus
title_short RELIABILITY OF A SIMPLE NOVEL FIELD TEST FOR THE MEASUREMENT OF PLANTAR FLEXOR MUSCLE STRENGTH
title_full RELIABILITY OF A SIMPLE NOVEL FIELD TEST FOR THE MEASUREMENT OF PLANTAR FLEXOR MUSCLE STRENGTH
title_fullStr RELIABILITY OF A SIMPLE NOVEL FIELD TEST FOR THE MEASUREMENT OF PLANTAR FLEXOR MUSCLE STRENGTH
title_full_unstemmed RELIABILITY OF A SIMPLE NOVEL FIELD TEST FOR THE MEASUREMENT OF PLANTAR FLEXOR MUSCLE STRENGTH
title_sort RELIABILITY OF A SIMPLE NOVEL FIELD TEST FOR THE MEASUREMENT OF PLANTAR FLEXOR MUSCLE STRENGTH
author Majstorović,Nikola
author_facet Majstorović,Nikola
Nešić,Goran
Grbić,Vladimir
Savić,Zoran
Živković,Milena
Aničić,Zdravko
Marković,Stefan
Dopsaj,Milivoj
author_role author
author2 Nešić,Goran
Grbić,Vladimir
Savić,Zoran
Živković,Milena
Aničić,Zdravko
Marković,Stefan
Dopsaj,Milivoj
author2_role author
author
author
author
author
author
author
dc.contributor.author.fl_str_mv Majstorović,Nikola
Nešić,Goran
Grbić,Vladimir
Savić,Zoran
Živković,Milena
Aničić,Zdravko
Marković,Stefan
Dopsaj,Milivoj
dc.subject.por.fl_str_mv Muscle strength
Dynamometer
Gastrocnemius
Soleus
topic Muscle strength
Dynamometer
Gastrocnemius
Soleus
description ABSTRACT Introduction When a person is in a standing position, the plantar flexor muscles are involved in most static and dynamic body movements. Objectives The aim of this study was to investigate the trial to trial and factorial reliability of measuring the contractile characteristics of PF muscles using a simple novel field test. Methods The sample consisted of 452 healthy subjects, 120 male and 332 female. The research was conducted by means of the trial to trial testing method, using isometric dynamometry performed in field conditions. ANOVA was used to estimate the differences among the trials, Cronbach’s alpha and interclass correlation to estimate the correlations among the trials, and principal component analysis to evaluate the contribution of each trial to overall variability. Results The main findings of this study are that trials differed significantly (p<0.000) for maximal force (Fmax) and maximal rate of force development (RFDmax), indicating that the three procedural trials were necessary. The trials were highly correlated (Fmax, RFDmax, r>0.9), proving that measuring was reliable, and the factorial analysis separated the second and third trials, the second trial accounting for most of the total variability. Conclusions The simple novel field test for the measurement of plantar flexor contractile characteristics recommended by this study proved to be as highly reliable as laboratory testing, but was easy to perform in conditions outside of scientific or diagnostic institutions, which greatly facilitates the work of scientists, coaches and professionals. Level of Evidence II; Diagnostic Studies – Investigating a diagnostics test.
publishDate 2021
dc.date.none.fl_str_mv 2021-01-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1517-86922021000100098
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1517-86922021000100098
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/1517-8692202127012019_0002
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Medicina do Exercício e do Esporte
publisher.none.fl_str_mv Sociedade Brasileira de Medicina do Exercício e do Esporte
dc.source.none.fl_str_mv Revista Brasileira de Medicina do Esporte v.27 n.1 2021
reponame:Revista brasileira de medicina do esporte (Online)
instname:Sociedade Brasileira de Medicina do Exercício e do Esporte (SBMEE)
instacron:SBMEE
instname_str Sociedade Brasileira de Medicina do Exercício e do Esporte (SBMEE)
instacron_str SBMEE
institution SBMEE
reponame_str Revista brasileira de medicina do esporte (Online)
collection Revista brasileira de medicina do esporte (Online)
repository.name.fl_str_mv Revista brasileira de medicina do esporte (Online) - Sociedade Brasileira de Medicina do Exercício e do Esporte (SBMEE)
repository.mail.fl_str_mv ||revista@medicinadoesporte.org.br
_version_ 1752122237567107072