Analysis and Comparison of Sensors for Measurements of Partial Discharges in Hydrogenerator Stator Windings

Detalhes bibliográficos
Autor(a) principal: Dmitriev,Victor
Data de Publicação: 2015
Outros Autores: Oliveira,Rodrigo M. S. de, Brasil,Fernando S., Vilhena,Paulo R. M. de, Modesto,Jonathas F. M., Zampolo,Ronaldo F.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Journal of Microwaves. Optoelectronics and Electromagnetic Applications
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S2179-10742015000200197
Resumo: Abstract In order to measure electrical signals produced by partial discharges in hydrogenerators stator windings, capacitive couplers are regularly used. They are electrically connected to the windings and therefore, require undesired insulation intrusion. For avoiding such an intrusion, a microstrip directional coupler is used, which is experimentally and numerically investigated in this work. This electromagnetic field sensor is analyzed initially via computer simulation using the finite-difference time-domain method. This numerical analysis is fulfilled considering the coupler placed over a stator bar. Experimental high-voltage tests with generator windings were also performed. We compare the results of the measurements obtained by using various sensors and show that the microstrip directional coupler has some important advantages over traditional capacitive sensors such as complete conductive insulation from the windings and the capacity of detecting shorter PD pulses due to their wider bandwidth.
id SBMO-1_77c2a17fd94154e1a7df1dc8f5e71596
oai_identifier_str oai:scielo:S2179-10742015000200197
network_acronym_str SBMO-1
network_name_str Journal of Microwaves. Optoelectronics and Electromagnetic Applications
repository_id_str
spelling Analysis and Comparison of Sensors for Measurements of Partial Discharges in Hydrogenerator Stator WindingsPartial dischargeshydrogenerator stator windingsmicrostrip directional couplerhigh-voltage experimentsFDTD simulationsAbstract In order to measure electrical signals produced by partial discharges in hydrogenerators stator windings, capacitive couplers are regularly used. They are electrically connected to the windings and therefore, require undesired insulation intrusion. For avoiding such an intrusion, a microstrip directional coupler is used, which is experimentally and numerically investigated in this work. This electromagnetic field sensor is analyzed initially via computer simulation using the finite-difference time-domain method. This numerical analysis is fulfilled considering the coupler placed over a stator bar. Experimental high-voltage tests with generator windings were also performed. We compare the results of the measurements obtained by using various sensors and show that the microstrip directional coupler has some important advantages over traditional capacitive sensors such as complete conductive insulation from the windings and the capacity of detecting shorter PD pulses due to their wider bandwidth.Sociedade Brasileira de Microondas e Optoeletrônica e Sociedade Brasileira de Eletromagnetismo2015-12-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S2179-10742015000200197Journal of Microwaves, Optoelectronics and Electromagnetic Applications v.14 n.2 2015reponame:Journal of Microwaves. Optoelectronics and Electromagnetic Applicationsinstname:Sociedade Brasileira de Microondas e Optoeletrônica (SBMO)instacron:SBMO10.1590/2179-10742015v14i2526info:eu-repo/semantics/openAccessDmitriev,VictorOliveira,Rodrigo M. S. deBrasil,Fernando S.Vilhena,Paulo R. M. deModesto,Jonathas F. M.Zampolo,Ronaldo F.eng2016-01-08T00:00:00Zoai:scielo:S2179-10742015000200197Revistahttp://www.jmoe.org/index.php/jmoe/indexONGhttps://old.scielo.br/oai/scielo-oai.php||editor_jmoe@sbmo.org.br2179-10742179-1074opendoar:2016-01-08T00:00Journal of Microwaves. Optoelectronics and Electromagnetic Applications - Sociedade Brasileira de Microondas e Optoeletrônica (SBMO)false
dc.title.none.fl_str_mv Analysis and Comparison of Sensors for Measurements of Partial Discharges in Hydrogenerator Stator Windings
title Analysis and Comparison of Sensors for Measurements of Partial Discharges in Hydrogenerator Stator Windings
spellingShingle Analysis and Comparison of Sensors for Measurements of Partial Discharges in Hydrogenerator Stator Windings
Dmitriev,Victor
Partial discharges
hydrogenerator stator windings
microstrip directional coupler
high-voltage experiments
FDTD simulations
title_short Analysis and Comparison of Sensors for Measurements of Partial Discharges in Hydrogenerator Stator Windings
title_full Analysis and Comparison of Sensors for Measurements of Partial Discharges in Hydrogenerator Stator Windings
title_fullStr Analysis and Comparison of Sensors for Measurements of Partial Discharges in Hydrogenerator Stator Windings
title_full_unstemmed Analysis and Comparison of Sensors for Measurements of Partial Discharges in Hydrogenerator Stator Windings
title_sort Analysis and Comparison of Sensors for Measurements of Partial Discharges in Hydrogenerator Stator Windings
author Dmitriev,Victor
author_facet Dmitriev,Victor
Oliveira,Rodrigo M. S. de
Brasil,Fernando S.
Vilhena,Paulo R. M. de
Modesto,Jonathas F. M.
Zampolo,Ronaldo F.
author_role author
author2 Oliveira,Rodrigo M. S. de
Brasil,Fernando S.
Vilhena,Paulo R. M. de
Modesto,Jonathas F. M.
Zampolo,Ronaldo F.
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv Dmitriev,Victor
Oliveira,Rodrigo M. S. de
Brasil,Fernando S.
Vilhena,Paulo R. M. de
Modesto,Jonathas F. M.
Zampolo,Ronaldo F.
dc.subject.por.fl_str_mv Partial discharges
hydrogenerator stator windings
microstrip directional coupler
high-voltage experiments
FDTD simulations
topic Partial discharges
hydrogenerator stator windings
microstrip directional coupler
high-voltage experiments
FDTD simulations
description Abstract In order to measure electrical signals produced by partial discharges in hydrogenerators stator windings, capacitive couplers are regularly used. They are electrically connected to the windings and therefore, require undesired insulation intrusion. For avoiding such an intrusion, a microstrip directional coupler is used, which is experimentally and numerically investigated in this work. This electromagnetic field sensor is analyzed initially via computer simulation using the finite-difference time-domain method. This numerical analysis is fulfilled considering the coupler placed over a stator bar. Experimental high-voltage tests with generator windings were also performed. We compare the results of the measurements obtained by using various sensors and show that the microstrip directional coupler has some important advantages over traditional capacitive sensors such as complete conductive insulation from the windings and the capacity of detecting shorter PD pulses due to their wider bandwidth.
publishDate 2015
dc.date.none.fl_str_mv 2015-12-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S2179-10742015000200197
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S2179-10742015000200197
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/2179-10742015v14i2526
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Microondas e Optoeletrônica e Sociedade Brasileira de Eletromagnetismo
publisher.none.fl_str_mv Sociedade Brasileira de Microondas e Optoeletrônica e Sociedade Brasileira de Eletromagnetismo
dc.source.none.fl_str_mv Journal of Microwaves, Optoelectronics and Electromagnetic Applications v.14 n.2 2015
reponame:Journal of Microwaves. Optoelectronics and Electromagnetic Applications
instname:Sociedade Brasileira de Microondas e Optoeletrônica (SBMO)
instacron:SBMO
instname_str Sociedade Brasileira de Microondas e Optoeletrônica (SBMO)
instacron_str SBMO
institution SBMO
reponame_str Journal of Microwaves. Optoelectronics and Electromagnetic Applications
collection Journal of Microwaves. Optoelectronics and Electromagnetic Applications
repository.name.fl_str_mv Journal of Microwaves. Optoelectronics and Electromagnetic Applications - Sociedade Brasileira de Microondas e Optoeletrônica (SBMO)
repository.mail.fl_str_mv ||editor_jmoe@sbmo.org.br
_version_ 1752122125810925568