M-mode echocardiography measurements of healthy Brazilian random bred cats

Detalhes bibliográficos
Autor(a) principal: Alberigi, Bruno
Data de Publicação: 2019
Outros Autores: Bendas, Alexandre José Rodrigues, Soares, Denise do Vale, Athar, Carolina Aben, Batalha, Fabiana Knacfuss, Demo, Renan Salhab, Paiva, Jonimar da Silva
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Brazilian Journal of Veterinary Medicine
Texto Completo: https://rbmv.org/BJVM/article/view/1029
Resumo: To determine the M-mode echocardiography reference measurements for Brazilian random bred cats in Rio de Janeiro, Brazil, Cats presenting for routine care were examined by M-mode echocardiography. Animals with free wall values ​​of the left ventricle and/or interventricular septum above 5 mm were not included. A total of 125 cats were included in the study. The correlation of the body score condition (BSC) with the echocardiography measurements was positive for left ventricle wall in systole (LVWs)  and left ventricular wall in diastole (LVWd) . The LVWd values of BSCs 3 and 4 were different , and those of BSCs 3 and 5 were also different. The LVWs values of BSCs 3 and 5 were different . The correlated effect between BSC and the echocardiography measurements was true for the left atrium , left atrium/aorta ratio, ventricular septum in diastole, ventricular septum in systole, LVWs, LVWd, left ventricle in diastole, left ventricle in systole, ejection fraction and shortening fraction. The M-mode echocardiography evaluation of cats is impacted by the animal’s body mass; therefore, the BSC must be taken into consideration when interpreting echocardiography measurements. 
id SBMV-1_1ca7a668804c1b2e284f2b34d9a22d89
oai_identifier_str oai:ojs.rbmv.org:article/1029
network_acronym_str SBMV-1
network_name_str Brazilian Journal of Veterinary Medicine
repository_id_str
spelling M-mode echocardiography measurements of healthy Brazilian random bred catsMedidas ecocardiográficas em Modo-M de gatos brasileiros sem raça definidacardiomiopatia, valores de referência, septo interventricular, parede ventricular esquerdacardiomyopathyleft ventricular wallinterventricular septumreference valuesTo determine the M-mode echocardiography reference measurements for Brazilian random bred cats in Rio de Janeiro, Brazil, Cats presenting for routine care were examined by M-mode echocardiography. Animals with free wall values ​​of the left ventricle and/or interventricular septum above 5 mm were not included. A total of 125 cats were included in the study. The correlation of the body score condition (BSC) with the echocardiography measurements was positive for left ventricle wall in systole (LVWs)  and left ventricular wall in diastole (LVWd) . The LVWd values of BSCs 3 and 4 were different , and those of BSCs 3 and 5 were also different. The LVWs values of BSCs 3 and 5 were different . The correlated effect between BSC and the echocardiography measurements was true for the left atrium , left atrium/aorta ratio, ventricular septum in diastole, ventricular septum in systole, LVWs, LVWd, left ventricle in diastole, left ventricle in systole, ejection fraction and shortening fraction. The M-mode echocardiography evaluation of cats is impacted by the animal’s body mass; therefore, the BSC must be taken into consideration when interpreting echocardiography measurements. Para determinar as medidas de referência da ecocardiografia modo-M para gatos brasileiros sem raça definida no Rio de Janeiro,  gatos que se apresentaram na rotina clínica foram examinados pela ecocardiografia no modo-M. Animais com parede livre do ventrículo esquerdo e / ou septo interventricular acima de 5 mm não foram incluídos.  Um total de 125 gatos foram incluídos no estudo. A correlação da condição do escore corporal (ECC) com as medidas do ecocardiograma foi positiva para parede do ventrículo esquerdo na sístole (PLVEs) e parede do ventrículo esquerdo na diástole (PLVEd). Os valores de PLVEd dos naimais com ECC 3 e 4 foram diferentes e os com ECC 3 e 5 também foram diferentes. Os valores de PLVE dos animais com ECC 3 e 5 também foram diferentes. O efeito correlatcionado entre o ECC e a ecocardiografia foi verdadeiro para o átrio esquerdo, relação átrio esquerdo / aorta, septo ventricular em diástole, septo ventricular em sístole, PLVEs, PLVEd, ventrículo esquerdo em diástole, ventrículo esquerdo em sístole, fração de ejeção e encurtamento fração. A avaliação ecocardiográfica do modo M dos gatos é afetada pela massa corporal do animal; portanto, o ECC deve ser levado em consideração ao interpretar medidas de ecocardiografia. Sociedade de Medicina Veterinária do Estado do Rio de Janeiro.2019-06-26info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionpeer reviewedAvaliado pelos paresapplication/pdfhttps://rbmv.org/BJVM/article/view/102910.29374/2527-2179.bjvm102919Brazilian Journal of Veterinary Medicine; Vol. 41 No. 1 (2019); e102919Revista Brasileira de Medicina Veterinária; v. 41 n. 1 (2019); e1029192527-21790100-2430reponame:Brazilian Journal of Veterinary Medicineinstname:Sociedade de Medicina Veterinária do Estado do Rio de Janeiro (SOMVERJ)instacron:SBMVenghttps://rbmv.org/BJVM/article/view/1029/949Copyright (c) 2019 Bruno Alberigi, Alexandre José Rodrigues Bendas, Denise do Vale Soares, Carolina Aben Athar, Fabiana Knacfuss Batalha, Renan Salhab Demo, Jonimar da Silva Paiva, Deceasedinfo:eu-repo/semantics/openAccessAlberigi, BrunoBendas, Alexandre José RodriguesSoares, Denise do ValeAthar, Carolina AbenBatalha, Fabiana KnacfussDemo, Renan SalhabPaiva, Jonimar da Silva2020-12-23T17:24:50Zoai:ojs.rbmv.org:article/1029Revistahttps://rbmv.org/BJVMONGhttps://rbmv.org/BJVM/oaicontato.rbmv@gmail.com2527-21790100-2430opendoar:2020-12-23T17:24:50Brazilian Journal of Veterinary Medicine - Sociedade de Medicina Veterinária do Estado do Rio de Janeiro (SOMVERJ)false
dc.title.none.fl_str_mv M-mode echocardiography measurements of healthy Brazilian random bred cats
Medidas ecocardiográficas em Modo-M de gatos brasileiros sem raça definida
title M-mode echocardiography measurements of healthy Brazilian random bred cats
spellingShingle M-mode echocardiography measurements of healthy Brazilian random bred cats
Alberigi, Bruno
cardiomiopatia, valores de referência, septo interventricular, parede ventricular esquerda
cardiomyopathy
left ventricular wall
interventricular septum
reference values
title_short M-mode echocardiography measurements of healthy Brazilian random bred cats
title_full M-mode echocardiography measurements of healthy Brazilian random bred cats
title_fullStr M-mode echocardiography measurements of healthy Brazilian random bred cats
title_full_unstemmed M-mode echocardiography measurements of healthy Brazilian random bred cats
title_sort M-mode echocardiography measurements of healthy Brazilian random bred cats
author Alberigi, Bruno
author_facet Alberigi, Bruno
Bendas, Alexandre José Rodrigues
Soares, Denise do Vale
Athar, Carolina Aben
Batalha, Fabiana Knacfuss
Demo, Renan Salhab
Paiva, Jonimar da Silva
author_role author
author2 Bendas, Alexandre José Rodrigues
Soares, Denise do Vale
Athar, Carolina Aben
Batalha, Fabiana Knacfuss
Demo, Renan Salhab
Paiva, Jonimar da Silva
author2_role author
author
author
author
author
author
dc.contributor.author.fl_str_mv Alberigi, Bruno
Bendas, Alexandre José Rodrigues
Soares, Denise do Vale
Athar, Carolina Aben
Batalha, Fabiana Knacfuss
Demo, Renan Salhab
Paiva, Jonimar da Silva
dc.subject.por.fl_str_mv cardiomiopatia, valores de referência, septo interventricular, parede ventricular esquerda
cardiomyopathy
left ventricular wall
interventricular septum
reference values
topic cardiomiopatia, valores de referência, septo interventricular, parede ventricular esquerda
cardiomyopathy
left ventricular wall
interventricular septum
reference values
description To determine the M-mode echocardiography reference measurements for Brazilian random bred cats in Rio de Janeiro, Brazil, Cats presenting for routine care were examined by M-mode echocardiography. Animals with free wall values ​​of the left ventricle and/or interventricular septum above 5 mm were not included. A total of 125 cats were included in the study. The correlation of the body score condition (BSC) with the echocardiography measurements was positive for left ventricle wall in systole (LVWs)  and left ventricular wall in diastole (LVWd) . The LVWd values of BSCs 3 and 4 were different , and those of BSCs 3 and 5 were also different. The LVWs values of BSCs 3 and 5 were different . The correlated effect between BSC and the echocardiography measurements was true for the left atrium , left atrium/aorta ratio, ventricular septum in diastole, ventricular septum in systole, LVWs, LVWd, left ventricle in diastole, left ventricle in systole, ejection fraction and shortening fraction. The M-mode echocardiography evaluation of cats is impacted by the animal’s body mass; therefore, the BSC must be taken into consideration when interpreting echocardiography measurements. 
publishDate 2019
dc.date.none.fl_str_mv 2019-06-26
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
peer reviewed
Avaliado pelos pares
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://rbmv.org/BJVM/article/view/1029
10.29374/2527-2179.bjvm102919
url https://rbmv.org/BJVM/article/view/1029
identifier_str_mv 10.29374/2527-2179.bjvm102919
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv https://rbmv.org/BJVM/article/view/1029/949
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Sociedade de Medicina Veterinária do Estado do Rio de Janeiro.
publisher.none.fl_str_mv Sociedade de Medicina Veterinária do Estado do Rio de Janeiro.
dc.source.none.fl_str_mv Brazilian Journal of Veterinary Medicine; Vol. 41 No. 1 (2019); e102919
Revista Brasileira de Medicina Veterinária; v. 41 n. 1 (2019); e102919
2527-2179
0100-2430
reponame:Brazilian Journal of Veterinary Medicine
instname:Sociedade de Medicina Veterinária do Estado do Rio de Janeiro (SOMVERJ)
instacron:SBMV
instname_str Sociedade de Medicina Veterinária do Estado do Rio de Janeiro (SOMVERJ)
instacron_str SBMV
institution SBMV
reponame_str Brazilian Journal of Veterinary Medicine
collection Brazilian Journal of Veterinary Medicine
repository.name.fl_str_mv Brazilian Journal of Veterinary Medicine - Sociedade de Medicina Veterinária do Estado do Rio de Janeiro (SOMVERJ)
repository.mail.fl_str_mv contato.rbmv@gmail.com
_version_ 1798313110585475072