Surgical management of retinal fold after 23-Gauge pars plana vitrectomy retinopexy

Detalhes bibliográficos
Autor(a) principal: Souza,Osias Francisco de
Data de Publicação: 2018
Outros Autores: Souza,Lais Bomediano de, Cassella,Antonio Marcelo Barbante
Tipo de documento: Relatório
Idioma: eng
Título da fonte: Revista Brasileira de Oftalmologia (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-72802018000300156
Resumo: Abstract The authors report a case of retinal fold after retinal detachment repair performed using 23-gauge pars plana vitrectomy technic (PPV). The fundus photography and optical coherence tomography (OCT) showed a posterior retinal fold with the retina periphery attached. The patient’s best corrected visual acuity (BCVA) was 20/200 with severe metamorphopsia. A 25-gauge PPV, subretinal balanced saline solution (BSS) injection using a 25-39-gauge cannula, and gas-fluid exchange were performed. The patient’s BCVA improved significantly after treatment. The retinal fold observed is not a frequent complication and can be managed with PPV, subretinal BSS injection and fluid-air exchange.
id SBO-1_ae9d9538967a161f19917ed42b5e6271
oai_identifier_str oai:scielo:S0034-72802018000300156
network_acronym_str SBO-1
network_name_str Revista Brasileira de Oftalmologia (Online)
repository_id_str
spelling Surgical management of retinal fold after 23-Gauge pars plana vitrectomy retinopexyVitrectomy/methodsVitreous body/surgeryVitrectomy/adverse effectsRetinal detachment/surgeryCase reportsAbstract The authors report a case of retinal fold after retinal detachment repair performed using 23-gauge pars plana vitrectomy technic (PPV). The fundus photography and optical coherence tomography (OCT) showed a posterior retinal fold with the retina periphery attached. The patient’s best corrected visual acuity (BCVA) was 20/200 with severe metamorphopsia. A 25-gauge PPV, subretinal balanced saline solution (BSS) injection using a 25-39-gauge cannula, and gas-fluid exchange were performed. The patient’s BCVA improved significantly after treatment. The retinal fold observed is not a frequent complication and can be managed with PPV, subretinal BSS injection and fluid-air exchange.Sociedade Brasileira de Oftalmologia2018-06-01info:eu-repo/semantics/reportinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-72802018000300156Revista Brasileira de Oftalmologia v.77 n.3 2018reponame:Revista Brasileira de Oftalmologia (Online)instname:Sociedade Brasileira de Oftalmologia (SBO)instacron:SBO10.5935/0034-7280.20180035info:eu-repo/semantics/openAccessSouza,Osias Francisco deSouza,Lais Bomediano deCassella,Antonio Marcelo Barbanteeng2018-06-20T00:00:00Zoai:scielo:S0034-72802018000300156Revistahttps://rbo.emnuvens.com.br/rbo/indexhttps://old.scielo.br/oai/scielo-oai.phpsob@sboportal.org.br||rbo@sboportal.org.br1982-85510034-7280opendoar:2018-06-20T00:00Revista Brasileira de Oftalmologia (Online) - Sociedade Brasileira de Oftalmologia (SBO)false
dc.title.none.fl_str_mv Surgical management of retinal fold after 23-Gauge pars plana vitrectomy retinopexy
title Surgical management of retinal fold after 23-Gauge pars plana vitrectomy retinopexy
spellingShingle Surgical management of retinal fold after 23-Gauge pars plana vitrectomy retinopexy
Souza,Osias Francisco de
Vitrectomy/methods
Vitreous body/surgery
Vitrectomy/adverse effects
Retinal detachment/surgery
Case reports
title_short Surgical management of retinal fold after 23-Gauge pars plana vitrectomy retinopexy
title_full Surgical management of retinal fold after 23-Gauge pars plana vitrectomy retinopexy
title_fullStr Surgical management of retinal fold after 23-Gauge pars plana vitrectomy retinopexy
title_full_unstemmed Surgical management of retinal fold after 23-Gauge pars plana vitrectomy retinopexy
title_sort Surgical management of retinal fold after 23-Gauge pars plana vitrectomy retinopexy
author Souza,Osias Francisco de
author_facet Souza,Osias Francisco de
Souza,Lais Bomediano de
Cassella,Antonio Marcelo Barbante
author_role author
author2 Souza,Lais Bomediano de
Cassella,Antonio Marcelo Barbante
author2_role author
author
dc.contributor.author.fl_str_mv Souza,Osias Francisco de
Souza,Lais Bomediano de
Cassella,Antonio Marcelo Barbante
dc.subject.por.fl_str_mv Vitrectomy/methods
Vitreous body/surgery
Vitrectomy/adverse effects
Retinal detachment/surgery
Case reports
topic Vitrectomy/methods
Vitreous body/surgery
Vitrectomy/adverse effects
Retinal detachment/surgery
Case reports
description Abstract The authors report a case of retinal fold after retinal detachment repair performed using 23-gauge pars plana vitrectomy technic (PPV). The fundus photography and optical coherence tomography (OCT) showed a posterior retinal fold with the retina periphery attached. The patient’s best corrected visual acuity (BCVA) was 20/200 with severe metamorphopsia. A 25-gauge PPV, subretinal balanced saline solution (BSS) injection using a 25-39-gauge cannula, and gas-fluid exchange were performed. The patient’s BCVA improved significantly after treatment. The retinal fold observed is not a frequent complication and can be managed with PPV, subretinal BSS injection and fluid-air exchange.
publishDate 2018
dc.date.none.fl_str_mv 2018-06-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/report
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format report
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-72802018000300156
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-72802018000300156
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.5935/0034-7280.20180035
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Oftalmologia
publisher.none.fl_str_mv Sociedade Brasileira de Oftalmologia
dc.source.none.fl_str_mv Revista Brasileira de Oftalmologia v.77 n.3 2018
reponame:Revista Brasileira de Oftalmologia (Online)
instname:Sociedade Brasileira de Oftalmologia (SBO)
instacron:SBO
instname_str Sociedade Brasileira de Oftalmologia (SBO)
instacron_str SBO
institution SBO
reponame_str Revista Brasileira de Oftalmologia (Online)
collection Revista Brasileira de Oftalmologia (Online)
repository.name.fl_str_mv Revista Brasileira de Oftalmologia (Online) - Sociedade Brasileira de Oftalmologia (SBO)
repository.mail.fl_str_mv sob@sboportal.org.br||rbo@sboportal.org.br
_version_ 1752122338284929024