Resumo: Abstract Purpose: To present the design and implementation of an amblyopia risk factors screening project, in a large based Portuguese population. Methods: Two referral centers have been enrolled to assess all children aged 2 under their direct referral area. The photoscreener used was PlusOptix ® A09. At this age, the cut-off defined for referral was: ≥1 Diopter (D) of anisometropia, ≥1.5D of astigmatism, ≥2D of myopia and ≥1.5D of hyperopia. The results were reported to a reading platform that allowed the ophthalmologist to see all exams, and provide timely appointment with a complete ophthalmologic assessment for those who needed. Results: A total of 2867 photo screens were made to the population eligible to both referral centers, which comprises a coverage rate of 55%. Out of 2611 children under one of the referral area, 53% (n=1395) adhered to the screening. Within these children, 17.5% (n=245) were referred and 15.3 % (n=214) appointments were performed. The comparison of refraction between PlusOptix ® and cycloplegic refraction showed a strong correlation regarding the sphere and cylinder values. From the 214 children observed in consultation, glasses were prescribed in 25.7% (n=55), corresponding to 3.9% of all screened children under one of the referral area. This screening method showed a positive predictive value of 58.4%. Conclusion: This screening program may be highly relevant to eradicate untreated amblyopia from our population. The results may lead to the implementation of this project to the whole country.
id SBO-1_ccaa5e54669b2965b0b69a6363c15026
oai_identifier_str oai:scielo:S0034-72802018000300133
network_acronym_str SBO-1
network_name_str Revista Brasileira de Oftalmologia (Online)
repository_id_str
spelling Preverbal visual photo screening Project implementation in PortugalAmblyopia/diagnosisMass screeningRisk factorsPortugalAbstract Purpose: To present the design and implementation of an amblyopia risk factors screening project, in a large based Portuguese population. Methods: Two referral centers have been enrolled to assess all children aged 2 under their direct referral area. The photoscreener used was PlusOptix ® A09. At this age, the cut-off defined for referral was: ≥1 Diopter (D) of anisometropia, ≥1.5D of astigmatism, ≥2D of myopia and ≥1.5D of hyperopia. The results were reported to a reading platform that allowed the ophthalmologist to see all exams, and provide timely appointment with a complete ophthalmologic assessment for those who needed. Results: A total of 2867 photo screens were made to the population eligible to both referral centers, which comprises a coverage rate of 55%. Out of 2611 children under one of the referral area, 53% (n=1395) adhered to the screening. Within these children, 17.5% (n=245) were referred and 15.3 % (n=214) appointments were performed. The comparison of refraction between PlusOptix ® and cycloplegic refraction showed a strong correlation regarding the sphere and cylinder values. From the 214 children observed in consultation, glasses were prescribed in 25.7% (n=55), corresponding to 3.9% of all screened children under one of the referral area. This screening method showed a positive predictive value of 58.4%. Conclusion: This screening program may be highly relevant to eradicate untreated amblyopia from our population. The results may lead to the implementation of this project to the whole country.Sociedade Brasileira de Oftalmologia2018-06-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-72802018000300133Revista Brasileira de Oftalmologia v.77 n.3 2018reponame:Revista Brasileira de Oftalmologia (Online)instname:Sociedade Brasileira de Oftalmologia (SBO)instacron:SBO10.5935/0034-7280.20180029info:eu-repo/semantics/openAccessCarneiro,InêsDias,DavidCasal,InêsMaia,SofiaMiranda,VascoParreira,RicardoMenéres,Pedroeng2018-06-20T00:00:00Zoai:scielo:S0034-72802018000300133Revistahttps://rbo.emnuvens.com.br/rbo/indexhttps://old.scielo.br/oai/scielo-oai.phpsob@sboportal.org.br||rbo@sboportal.org.br1982-85510034-7280opendoar:2018-06-20T00:00Revista Brasileira de Oftalmologia (Online) - Sociedade Brasileira de Oftalmologia (SBO)false
dc.title.none.fl_str_mv Preverbal visual photo screening Project implementation in Portugal
title Preverbal visual photo screening Project implementation in Portugal
spellingShingle Preverbal visual photo screening Project implementation in Portugal
Carneiro,Inês
Amblyopia/diagnosis
Mass screening
Risk factors
Portugal
title_short Preverbal visual photo screening Project implementation in Portugal
title_full Preverbal visual photo screening Project implementation in Portugal
title_fullStr Preverbal visual photo screening Project implementation in Portugal
title_full_unstemmed Preverbal visual photo screening Project implementation in Portugal
title_sort Preverbal visual photo screening Project implementation in Portugal
author Carneiro,Inês
author_facet Carneiro,Inês
Dias,David
Casal,Inês
Maia,Sofia
Miranda,Vasco
Parreira,Ricardo
Menéres,Pedro
author_role author
author2 Dias,David
Casal,Inês
Maia,Sofia
Miranda,Vasco
Parreira,Ricardo
Menéres,Pedro
author2_role author
author
author
author
author
author
dc.contributor.author.fl_str_mv Carneiro,Inês
Dias,David
Casal,Inês
Maia,Sofia
Miranda,Vasco
Parreira,Ricardo
Menéres,Pedro
dc.subject.por.fl_str_mv Amblyopia/diagnosis
Mass screening
Risk factors
Portugal
topic Amblyopia/diagnosis
Mass screening
Risk factors
Portugal
description Abstract Purpose: To present the design and implementation of an amblyopia risk factors screening project, in a large based Portuguese population. Methods: Two referral centers have been enrolled to assess all children aged 2 under their direct referral area. The photoscreener used was PlusOptix ® A09. At this age, the cut-off defined for referral was: ≥1 Diopter (D) of anisometropia, ≥1.5D of astigmatism, ≥2D of myopia and ≥1.5D of hyperopia. The results were reported to a reading platform that allowed the ophthalmologist to see all exams, and provide timely appointment with a complete ophthalmologic assessment for those who needed. Results: A total of 2867 photo screens were made to the population eligible to both referral centers, which comprises a coverage rate of 55%. Out of 2611 children under one of the referral area, 53% (n=1395) adhered to the screening. Within these children, 17.5% (n=245) were referred and 15.3 % (n=214) appointments were performed. The comparison of refraction between PlusOptix ® and cycloplegic refraction showed a strong correlation regarding the sphere and cylinder values. From the 214 children observed in consultation, glasses were prescribed in 25.7% (n=55), corresponding to 3.9% of all screened children under one of the referral area. This screening method showed a positive predictive value of 58.4%. Conclusion: This screening program may be highly relevant to eradicate untreated amblyopia from our population. The results may lead to the implementation of this project to the whole country.
publishDate 2018
dc.date.none.fl_str_mv 2018-06-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-72802018000300133
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-72802018000300133
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.5935/0034-7280.20180029
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Oftalmologia
publisher.none.fl_str_mv Sociedade Brasileira de Oftalmologia
dc.source.none.fl_str_mv Revista Brasileira de Oftalmologia v.77 n.3 2018
reponame:Revista Brasileira de Oftalmologia (Online)
instname:Sociedade Brasileira de Oftalmologia (SBO)
instacron:SBO
instname_str Sociedade Brasileira de Oftalmologia (SBO)
instacron_str SBO
institution SBO
reponame_str Revista Brasileira de Oftalmologia (Online)
collection Revista Brasileira de Oftalmologia (Online)
repository.name.fl_str_mv Revista Brasileira de Oftalmologia (Online) - Sociedade Brasileira de Oftalmologia (SBO)
repository.mail.fl_str_mv sob@sboportal.org.br||rbo@sboportal.org.br
_version_ 1752122338274443264