Evaluation of efficacy of new lens nucleus fragmenting forceps in cataract surgery
Autor(a) principal: | |
---|---|
Data de Publicação: | 2022 |
Outros Autores: | , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Revista Brasileira de Oftalmologia (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-72802022000100220 |
Resumo: | ABSTRACT Objective: To evaluate the efficacy of low-cost nucleus fragmenting forceps designed to reduce the use of ultrasound during phacoemulsification. Methods: A total of 60 pig eyes enucleated 10 hours before were placed in the microwave oven, at maximum power for 10 seconds, to form cataracts with hardness comparable to a grade IV nucleus in the Lens Opacities Classification System III. Cataract extraction was performed using the Centurion® phacoemulsifier (Alcon Laboratories, Geneve, Switzerland) and Leica M620 microscope. All eyes were submitted to the pre-chop technique dividing the nucleus into four parts. After the pre-chop, the quadrants in 30 eyes were phacoemulsified with the torsional mode and were fragmented in the remaining 30 eyes after the pre-chop was with the fragmentation forceps before torsional mode phacoemulsification. The device was calibrated for all eyes by applying the following parameters: 40% linear torsional phacoemulsification; intraocular pressure of 65 mmHg; the linear vacuum of 600 mmHg; aspiration flow of 40 ccs/minute. After each procedure, the following was recorded: cumulative dissipated energy; equivalent average torsional amplitude; equivalent average ultrasonic power; estimated aspirated fluid; ultrasound total time; and total aspiration time. Statistical analysis was performed using the Kruskal-Wallis test and the IBM Statistical Package for Social Sciences. The p-value <0.05 was considered statistically significant. Results: There was a statistically significant reduction favoring the use of the nucleus fragmenting forceps in all parameters, except for the average torsional amplitude. Conclusion: The use of the nucleus fragmenting forceps contributed to improving the efficacy of torsional phacoemulsification in enucleated pig eyes. |
id |
SBO-1_e3cff9a550c9f1241650f688108b2cd4 |
---|---|
oai_identifier_str |
oai:scielo:S0034-72802022000100220 |
network_acronym_str |
SBO-1 |
network_name_str |
Revista Brasileira de Oftalmologia (Online) |
repository_id_str |
|
spelling |
Evaluation of efficacy of new lens nucleus fragmenting forceps in cataract surgeryCataractPhacoemulsification/methodsRehabilitationABSTRACT Objective: To evaluate the efficacy of low-cost nucleus fragmenting forceps designed to reduce the use of ultrasound during phacoemulsification. Methods: A total of 60 pig eyes enucleated 10 hours before were placed in the microwave oven, at maximum power for 10 seconds, to form cataracts with hardness comparable to a grade IV nucleus in the Lens Opacities Classification System III. Cataract extraction was performed using the Centurion® phacoemulsifier (Alcon Laboratories, Geneve, Switzerland) and Leica M620 microscope. All eyes were submitted to the pre-chop technique dividing the nucleus into four parts. After the pre-chop, the quadrants in 30 eyes were phacoemulsified with the torsional mode and were fragmented in the remaining 30 eyes after the pre-chop was with the fragmentation forceps before torsional mode phacoemulsification. The device was calibrated for all eyes by applying the following parameters: 40% linear torsional phacoemulsification; intraocular pressure of 65 mmHg; the linear vacuum of 600 mmHg; aspiration flow of 40 ccs/minute. After each procedure, the following was recorded: cumulative dissipated energy; equivalent average torsional amplitude; equivalent average ultrasonic power; estimated aspirated fluid; ultrasound total time; and total aspiration time. Statistical analysis was performed using the Kruskal-Wallis test and the IBM Statistical Package for Social Sciences. The p-value <0.05 was considered statistically significant. Results: There was a statistically significant reduction favoring the use of the nucleus fragmenting forceps in all parameters, except for the average torsional amplitude. Conclusion: The use of the nucleus fragmenting forceps contributed to improving the efficacy of torsional phacoemulsification in enucleated pig eyes.Sociedade Brasileira de Oftalmologia2022-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-72802022000100220Revista Brasileira de Oftalmologia v.81 2022reponame:Revista Brasileira de Oftalmologia (Online)instname:Sociedade Brasileira de Oftalmologia (SBO)instacron:SBO10.37039/1982.8551.20220043info:eu-repo/semantics/openAccessFaria,Marco Antonio Rey deDemeda,Vanessa FaveroCabral,Ana Beatriz FlorêncioSintra,Ariovaldo Alves FialhoPinheiro,Francisco IrochimaAlves,Milton Ruizeng2022-06-08T00:00:00Zoai:scielo:S0034-72802022000100220Revistahttps://rbo.emnuvens.com.br/rbo/indexhttps://old.scielo.br/oai/scielo-oai.phpsob@sboportal.org.br||rbo@sboportal.org.br1982-85510034-7280opendoar:2022-06-08T00:00Revista Brasileira de Oftalmologia (Online) - Sociedade Brasileira de Oftalmologia (SBO)false |
dc.title.none.fl_str_mv |
Evaluation of efficacy of new lens nucleus fragmenting forceps in cataract surgery |
title |
Evaluation of efficacy of new lens nucleus fragmenting forceps in cataract surgery |
spellingShingle |
Evaluation of efficacy of new lens nucleus fragmenting forceps in cataract surgery Faria,Marco Antonio Rey de Cataract Phacoemulsification/methods Rehabilitation |
title_short |
Evaluation of efficacy of new lens nucleus fragmenting forceps in cataract surgery |
title_full |
Evaluation of efficacy of new lens nucleus fragmenting forceps in cataract surgery |
title_fullStr |
Evaluation of efficacy of new lens nucleus fragmenting forceps in cataract surgery |
title_full_unstemmed |
Evaluation of efficacy of new lens nucleus fragmenting forceps in cataract surgery |
title_sort |
Evaluation of efficacy of new lens nucleus fragmenting forceps in cataract surgery |
author |
Faria,Marco Antonio Rey de |
author_facet |
Faria,Marco Antonio Rey de Demeda,Vanessa Favero Cabral,Ana Beatriz Florêncio Sintra,Ariovaldo Alves Fialho Pinheiro,Francisco Irochima Alves,Milton Ruiz |
author_role |
author |
author2 |
Demeda,Vanessa Favero Cabral,Ana Beatriz Florêncio Sintra,Ariovaldo Alves Fialho Pinheiro,Francisco Irochima Alves,Milton Ruiz |
author2_role |
author author author author author |
dc.contributor.author.fl_str_mv |
Faria,Marco Antonio Rey de Demeda,Vanessa Favero Cabral,Ana Beatriz Florêncio Sintra,Ariovaldo Alves Fialho Pinheiro,Francisco Irochima Alves,Milton Ruiz |
dc.subject.por.fl_str_mv |
Cataract Phacoemulsification/methods Rehabilitation |
topic |
Cataract Phacoemulsification/methods Rehabilitation |
description |
ABSTRACT Objective: To evaluate the efficacy of low-cost nucleus fragmenting forceps designed to reduce the use of ultrasound during phacoemulsification. Methods: A total of 60 pig eyes enucleated 10 hours before were placed in the microwave oven, at maximum power for 10 seconds, to form cataracts with hardness comparable to a grade IV nucleus in the Lens Opacities Classification System III. Cataract extraction was performed using the Centurion® phacoemulsifier (Alcon Laboratories, Geneve, Switzerland) and Leica M620 microscope. All eyes were submitted to the pre-chop technique dividing the nucleus into four parts. After the pre-chop, the quadrants in 30 eyes were phacoemulsified with the torsional mode and were fragmented in the remaining 30 eyes after the pre-chop was with the fragmentation forceps before torsional mode phacoemulsification. The device was calibrated for all eyes by applying the following parameters: 40% linear torsional phacoemulsification; intraocular pressure of 65 mmHg; the linear vacuum of 600 mmHg; aspiration flow of 40 ccs/minute. After each procedure, the following was recorded: cumulative dissipated energy; equivalent average torsional amplitude; equivalent average ultrasonic power; estimated aspirated fluid; ultrasound total time; and total aspiration time. Statistical analysis was performed using the Kruskal-Wallis test and the IBM Statistical Package for Social Sciences. The p-value <0.05 was considered statistically significant. Results: There was a statistically significant reduction favoring the use of the nucleus fragmenting forceps in all parameters, except for the average torsional amplitude. Conclusion: The use of the nucleus fragmenting forceps contributed to improving the efficacy of torsional phacoemulsification in enucleated pig eyes. |
publishDate |
2022 |
dc.date.none.fl_str_mv |
2022-01-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-72802022000100220 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-72802022000100220 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.37039/1982.8551.20220043 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira de Oftalmologia |
publisher.none.fl_str_mv |
Sociedade Brasileira de Oftalmologia |
dc.source.none.fl_str_mv |
Revista Brasileira de Oftalmologia v.81 2022 reponame:Revista Brasileira de Oftalmologia (Online) instname:Sociedade Brasileira de Oftalmologia (SBO) instacron:SBO |
instname_str |
Sociedade Brasileira de Oftalmologia (SBO) |
instacron_str |
SBO |
institution |
SBO |
reponame_str |
Revista Brasileira de Oftalmologia (Online) |
collection |
Revista Brasileira de Oftalmologia (Online) |
repository.name.fl_str_mv |
Revista Brasileira de Oftalmologia (Online) - Sociedade Brasileira de Oftalmologia (SBO) |
repository.mail.fl_str_mv |
sob@sboportal.org.br||rbo@sboportal.org.br |
_version_ |
1752122339580968960 |