Resumo: PURPOSE: To demonstrate the corneal magnification using trypan blue in cataract surgery. METHODS: Eight eyes of eight patients undergoing phacoemulsification with an intraocular lens implantation were enrolled in this study. After staining the anterior capsule with Trypan Blue 0.1% and performing the capsulorhexis, the excised anterior capsule was placed on the corneal surface. By observing and measuring the relationship between the border of the excised anterior capsule and the intracameral capsulorhexis opening, the effect of corneal magnification was clearly demonstrated and calculated by linear method. RESULTS: The average magnification of the cornea was 20.88% using linear method with an average area magnification of 47.53%. CONCLUSION: The capsulorhexis stained by trypan blue is useful to demonstrate the magnification provided by the cornea helping to design an intended opening size.
id SBO-1_e55a8c29ffb7a793c2c2d74a7edb5057
oai_identifier_str oai:scielo:S0034-72802011000400006
network_acronym_str SBO-1
network_name_str Revista Brasileira de Oftalmologia (Online)
repository_id_str
spelling New technique to demonstrate corneal magnification using trypan blue in cataract surgeryCapsulorhexisPhacoemulsificationCorneal magnificationPURPOSE: To demonstrate the corneal magnification using trypan blue in cataract surgery. METHODS: Eight eyes of eight patients undergoing phacoemulsification with an intraocular lens implantation were enrolled in this study. After staining the anterior capsule with Trypan Blue 0.1% and performing the capsulorhexis, the excised anterior capsule was placed on the corneal surface. By observing and measuring the relationship between the border of the excised anterior capsule and the intracameral capsulorhexis opening, the effect of corneal magnification was clearly demonstrated and calculated by linear method. RESULTS: The average magnification of the cornea was 20.88% using linear method with an average area magnification of 47.53%. CONCLUSION: The capsulorhexis stained by trypan blue is useful to demonstrate the magnification provided by the cornea helping to design an intended opening size.Sociedade Brasileira de Oftalmologia2011-08-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-72802011000400006Revista Brasileira de Oftalmologia v.70 n.4 2011reponame:Revista Brasileira de Oftalmologia (Online)instname:Sociedade Brasileira de Oftalmologia (SBO)instacron:SBO10.1590/S0034-72802011000400006info:eu-repo/semantics/openAccessMarques,Frederico F.Marques,Daniela M.V.Osher,Robert H.eng2011-10-10T00:00:00Zoai:scielo:S0034-72802011000400006Revistahttps://rbo.emnuvens.com.br/rbo/indexhttps://old.scielo.br/oai/scielo-oai.phpsob@sboportal.org.br||rbo@sboportal.org.br1982-85510034-7280opendoar:2011-10-10T00:00Revista Brasileira de Oftalmologia (Online) - Sociedade Brasileira de Oftalmologia (SBO)false
dc.title.none.fl_str_mv New technique to demonstrate corneal magnification using trypan blue in cataract surgery
title New technique to demonstrate corneal magnification using trypan blue in cataract surgery
spellingShingle New technique to demonstrate corneal magnification using trypan blue in cataract surgery
Marques,Frederico F.
Capsulorhexis
Phacoemulsification
Corneal magnification
title_short New technique to demonstrate corneal magnification using trypan blue in cataract surgery
title_full New technique to demonstrate corneal magnification using trypan blue in cataract surgery
title_fullStr New technique to demonstrate corneal magnification using trypan blue in cataract surgery
title_full_unstemmed New technique to demonstrate corneal magnification using trypan blue in cataract surgery
title_sort New technique to demonstrate corneal magnification using trypan blue in cataract surgery
author Marques,Frederico F.
author_facet Marques,Frederico F.
Marques,Daniela M.V.
Osher,Robert H.
author_role author
author2 Marques,Daniela M.V.
Osher,Robert H.
author2_role author
author
dc.contributor.author.fl_str_mv Marques,Frederico F.
Marques,Daniela M.V.
Osher,Robert H.
dc.subject.por.fl_str_mv Capsulorhexis
Phacoemulsification
Corneal magnification
topic Capsulorhexis
Phacoemulsification
Corneal magnification
description PURPOSE: To demonstrate the corneal magnification using trypan blue in cataract surgery. METHODS: Eight eyes of eight patients undergoing phacoemulsification with an intraocular lens implantation were enrolled in this study. After staining the anterior capsule with Trypan Blue 0.1% and performing the capsulorhexis, the excised anterior capsule was placed on the corneal surface. By observing and measuring the relationship between the border of the excised anterior capsule and the intracameral capsulorhexis opening, the effect of corneal magnification was clearly demonstrated and calculated by linear method. RESULTS: The average magnification of the cornea was 20.88% using linear method with an average area magnification of 47.53%. CONCLUSION: The capsulorhexis stained by trypan blue is useful to demonstrate the magnification provided by the cornea helping to design an intended opening size.
publishDate 2011
dc.date.none.fl_str_mv 2011-08-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-72802011000400006
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-72802011000400006
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S0034-72802011000400006
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Oftalmologia
publisher.none.fl_str_mv Sociedade Brasileira de Oftalmologia
dc.source.none.fl_str_mv Revista Brasileira de Oftalmologia v.70 n.4 2011
reponame:Revista Brasileira de Oftalmologia (Online)
instname:Sociedade Brasileira de Oftalmologia (SBO)
instacron:SBO
instname_str Sociedade Brasileira de Oftalmologia (SBO)
instacron_str SBO
institution SBO
reponame_str Revista Brasileira de Oftalmologia (Online)
collection Revista Brasileira de Oftalmologia (Online)
repository.name.fl_str_mv Revista Brasileira de Oftalmologia (Online) - Sociedade Brasileira de Oftalmologia (SBO)
repository.mail.fl_str_mv sob@sboportal.org.br||rbo@sboportal.org.br
_version_ 1752122335966527488