COMPARATIVE STUDY OF MICROANASTOMOSIS WITH DISTINCT 10-0 NYLON SUTURES IN RATS

Detalhes bibliográficos
Autor(a) principal: Silva,Ricardo Teixeira e
Data de Publicação: 2016
Outros Autores: Barros,Thiago Felipe Santos, Carvalho,José Thomé de, Ribeiro,André Araújo, Pires,André Fernandes, Wei,Teng Hsiang
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Acta Ortopédica Brasileira (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-78522016000100035
Resumo: ABSTRACT Objective: The aim of this study is to compare micro-sutures commonly used in our midst. Methods: In this double-blind study, 30 Wistar rats were operated randomly divided into three groups matched according to the suture used (Nylon 10-0, 75micron, brands Microsuture(r), Polysuture(r) and Ethicon(r)). We analyzed the number of surgical nodes required, bleeding, surgical time and histological evaluation. Results: There was no significant difference between the amount of stitches of arterial suture per anastomosis. Surgical time was longer in Microsuture(r) group as compared to Polysuture(r) (p ≤ 0.05). Bleeding in Microsuture(r) group was higher when compared to the others (p <0.01). In the histological analysis, the Microsuture(r) group showed a greater tendency to develop fibrosis and aneurysm in surgical site than the others (p <0.01 and p≤0,05, respectively). Similarly, the Ethicon(r) group showed less tendency to myointimal proliferation than the rest. (p = 0.025). Conclusion: The results confirm the relevance of the choice of surgical thread as an independent determining factor for the success of the procedure, besides serving as a rational subsidy for a better cost-benefit analysis. Level of Evidence I, Experimental Study, Controlled Animal Study.
id SBOT-1_066bcab2e6aedc616015869afcff085a
oai_identifier_str oai:scielo:S1413-78522016000100035
network_acronym_str SBOT-1
network_name_str Acta Ortopédica Brasileira (Online)
repository_id_str
spelling COMPARATIVE STUDY OF MICROANASTOMOSIS WITH DISTINCT 10-0 NYLON SUTURES IN RATSAnastomosis, sugicalMicrosurgeryRats, WistarSuturesABSTRACT Objective: The aim of this study is to compare micro-sutures commonly used in our midst. Methods: In this double-blind study, 30 Wistar rats were operated randomly divided into three groups matched according to the suture used (Nylon 10-0, 75micron, brands Microsuture(r), Polysuture(r) and Ethicon(r)). We analyzed the number of surgical nodes required, bleeding, surgical time and histological evaluation. Results: There was no significant difference between the amount of stitches of arterial suture per anastomosis. Surgical time was longer in Microsuture(r) group as compared to Polysuture(r) (p ≤ 0.05). Bleeding in Microsuture(r) group was higher when compared to the others (p <0.01). In the histological analysis, the Microsuture(r) group showed a greater tendency to develop fibrosis and aneurysm in surgical site than the others (p <0.01 and p≤0,05, respectively). Similarly, the Ethicon(r) group showed less tendency to myointimal proliferation than the rest. (p = 0.025). Conclusion: The results confirm the relevance of the choice of surgical thread as an independent determining factor for the success of the procedure, besides serving as a rational subsidy for a better cost-benefit analysis. Level of Evidence I, Experimental Study, Controlled Animal Study.ATHA EDITORA2016-02-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-78522016000100035Acta Ortopédica Brasileira v.24 n.1 2016reponame:Acta Ortopédica Brasileira (Online)instname:Sociedade Brasileira de Ortopedia e Traumatologia (SBOT)instacron:SBOT10.1590/1413-785220162401152773info:eu-repo/semantics/openAccessSilva,Ricardo Teixeira eBarros,Thiago Felipe SantosCarvalho,José Thomé deRibeiro,André AraújoPires,André FernandesWei,Teng Hsiangeng2016-01-29T00:00:00Zoai:scielo:S1413-78522016000100035Revistahttp://www.actaortopedica.com.br/https://old.scielo.br/oai/scielo-oai.php1atha@uol.com.br||actaortopedicabrasileira@uol.com.br1809-44061413-7852opendoar:2016-01-29T00:00Acta Ortopédica Brasileira (Online) - Sociedade Brasileira de Ortopedia e Traumatologia (SBOT)false
dc.title.none.fl_str_mv COMPARATIVE STUDY OF MICROANASTOMOSIS WITH DISTINCT 10-0 NYLON SUTURES IN RATS
title COMPARATIVE STUDY OF MICROANASTOMOSIS WITH DISTINCT 10-0 NYLON SUTURES IN RATS
spellingShingle COMPARATIVE STUDY OF MICROANASTOMOSIS WITH DISTINCT 10-0 NYLON SUTURES IN RATS
Silva,Ricardo Teixeira e
Anastomosis, sugical
Microsurgery
Rats, Wistar
Sutures
title_short COMPARATIVE STUDY OF MICROANASTOMOSIS WITH DISTINCT 10-0 NYLON SUTURES IN RATS
title_full COMPARATIVE STUDY OF MICROANASTOMOSIS WITH DISTINCT 10-0 NYLON SUTURES IN RATS
title_fullStr COMPARATIVE STUDY OF MICROANASTOMOSIS WITH DISTINCT 10-0 NYLON SUTURES IN RATS
title_full_unstemmed COMPARATIVE STUDY OF MICROANASTOMOSIS WITH DISTINCT 10-0 NYLON SUTURES IN RATS
title_sort COMPARATIVE STUDY OF MICROANASTOMOSIS WITH DISTINCT 10-0 NYLON SUTURES IN RATS
author Silva,Ricardo Teixeira e
author_facet Silva,Ricardo Teixeira e
Barros,Thiago Felipe Santos
Carvalho,José Thomé de
Ribeiro,André Araújo
Pires,André Fernandes
Wei,Teng Hsiang
author_role author
author2 Barros,Thiago Felipe Santos
Carvalho,José Thomé de
Ribeiro,André Araújo
Pires,André Fernandes
Wei,Teng Hsiang
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv Silva,Ricardo Teixeira e
Barros,Thiago Felipe Santos
Carvalho,José Thomé de
Ribeiro,André Araújo
Pires,André Fernandes
Wei,Teng Hsiang
dc.subject.por.fl_str_mv Anastomosis, sugical
Microsurgery
Rats, Wistar
Sutures
topic Anastomosis, sugical
Microsurgery
Rats, Wistar
Sutures
description ABSTRACT Objective: The aim of this study is to compare micro-sutures commonly used in our midst. Methods: In this double-blind study, 30 Wistar rats were operated randomly divided into three groups matched according to the suture used (Nylon 10-0, 75micron, brands Microsuture(r), Polysuture(r) and Ethicon(r)). We analyzed the number of surgical nodes required, bleeding, surgical time and histological evaluation. Results: There was no significant difference between the amount of stitches of arterial suture per anastomosis. Surgical time was longer in Microsuture(r) group as compared to Polysuture(r) (p ≤ 0.05). Bleeding in Microsuture(r) group was higher when compared to the others (p <0.01). In the histological analysis, the Microsuture(r) group showed a greater tendency to develop fibrosis and aneurysm in surgical site than the others (p <0.01 and p≤0,05, respectively). Similarly, the Ethicon(r) group showed less tendency to myointimal proliferation than the rest. (p = 0.025). Conclusion: The results confirm the relevance of the choice of surgical thread as an independent determining factor for the success of the procedure, besides serving as a rational subsidy for a better cost-benefit analysis. Level of Evidence I, Experimental Study, Controlled Animal Study.
publishDate 2016
dc.date.none.fl_str_mv 2016-02-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-78522016000100035
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-78522016000100035
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/1413-785220162401152773
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv ATHA EDITORA
publisher.none.fl_str_mv ATHA EDITORA
dc.source.none.fl_str_mv Acta Ortopédica Brasileira v.24 n.1 2016
reponame:Acta Ortopédica Brasileira (Online)
instname:Sociedade Brasileira de Ortopedia e Traumatologia (SBOT)
instacron:SBOT
instname_str Sociedade Brasileira de Ortopedia e Traumatologia (SBOT)
instacron_str SBOT
institution SBOT
reponame_str Acta Ortopédica Brasileira (Online)
collection Acta Ortopédica Brasileira (Online)
repository.name.fl_str_mv Acta Ortopédica Brasileira (Online) - Sociedade Brasileira de Ortopedia e Traumatologia (SBOT)
repository.mail.fl_str_mv 1atha@uol.com.br||actaortopedicabrasileira@uol.com.br
_version_ 1752122275217276928