QUANTITATIVE EVALUATION OF EXPERIMENTAL BONE REGENERATION USING INDENTATION TESTS

Detalhes bibliográficos
Autor(a) principal: Vidotto,Valéria Trombini
Data de Publicação: 2017
Outros Autores: Batista,Nilza Alzira, Mariolani,José Ricardo Lenzi, Belangero,William Dias
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Acta Ortopédica Brasileira (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-78522017000200071
Resumo: ABSTRACT Objectives: To determine whether the macroindentation test can be applied to quantitatively assess bone regeneration. Methods: A 3.2 mm diameter transverse monocortical defect was created on the medial aspect of both proximal metaphyses of the tibia of male Unib-WH rats. For the macroindentation tests, we used 5.00 mm diameter indenters with a 3.2 mm tip. Defect testing was performed 1 to 12 weeks following the surgical procedures to compare the hardness of the newly developed tissue over the 12-week study period. Additional histological, morphological and physical/chemical data were obtained by optical and electronic microscopy, Raman, and energy dispersive x-ray spectrometry (EDS). Results: The mean indentation forces increased in a time-dependent manner from 4 to 12 weeks (p<0.001). Tests performed with the 5.0 mm diameter tip were not able to measure the indentation forces in the first week after the procedure. Moreover, in the second postoperative week indentation forces and the newly formed tissue within the spinal canal were greater than those measured in the fourth and eighth weeks. Conclusions: The macroindentation test can be used to quantitatively assess bone regeneration in experimental studies. The choice of indenter tip diameter should consider the study design. Level of Evidence II, Diagnostic Studies.
id SBOT-1_4f2c68bc5e636014d1b348a31909d625
oai_identifier_str oai:scielo:S1413-78522017000200071
network_acronym_str SBOT-1
network_name_str Acta Ortopédica Brasileira (Online)
repository_id_str
spelling QUANTITATIVE EVALUATION OF EXPERIMENTAL BONE REGENERATION USING INDENTATION TESTSBone regenerationHardness testsAnimal experimentationABSTRACT Objectives: To determine whether the macroindentation test can be applied to quantitatively assess bone regeneration. Methods: A 3.2 mm diameter transverse monocortical defect was created on the medial aspect of both proximal metaphyses of the tibia of male Unib-WH rats. For the macroindentation tests, we used 5.00 mm diameter indenters with a 3.2 mm tip. Defect testing was performed 1 to 12 weeks following the surgical procedures to compare the hardness of the newly developed tissue over the 12-week study period. Additional histological, morphological and physical/chemical data were obtained by optical and electronic microscopy, Raman, and energy dispersive x-ray spectrometry (EDS). Results: The mean indentation forces increased in a time-dependent manner from 4 to 12 weeks (p<0.001). Tests performed with the 5.0 mm diameter tip were not able to measure the indentation forces in the first week after the procedure. Moreover, in the second postoperative week indentation forces and the newly formed tissue within the spinal canal were greater than those measured in the fourth and eighth weeks. Conclusions: The macroindentation test can be used to quantitatively assess bone regeneration in experimental studies. The choice of indenter tip diameter should consider the study design. Level of Evidence II, Diagnostic Studies.ATHA EDITORA2017-04-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-78522017000200071Acta Ortopédica Brasileira v.25 n.2 2017reponame:Acta Ortopédica Brasileira (Online)instname:Sociedade Brasileira de Ortopedia e Traumatologia (SBOT)instacron:SBOT10.1590/1413-785220172502164015info:eu-repo/semantics/openAccessVidotto,Valéria TrombiniBatista,Nilza AlziraMariolani,José Ricardo LenziBelangero,William Diaseng2017-04-10T00:00:00Zoai:scielo:S1413-78522017000200071Revistahttp://www.actaortopedica.com.br/https://old.scielo.br/oai/scielo-oai.php1atha@uol.com.br||actaortopedicabrasileira@uol.com.br1809-44061413-7852opendoar:2017-04-10T00:00Acta Ortopédica Brasileira (Online) - Sociedade Brasileira de Ortopedia e Traumatologia (SBOT)false
dc.title.none.fl_str_mv QUANTITATIVE EVALUATION OF EXPERIMENTAL BONE REGENERATION USING INDENTATION TESTS
title QUANTITATIVE EVALUATION OF EXPERIMENTAL BONE REGENERATION USING INDENTATION TESTS
spellingShingle QUANTITATIVE EVALUATION OF EXPERIMENTAL BONE REGENERATION USING INDENTATION TESTS
Vidotto,Valéria Trombini
Bone regeneration
Hardness tests
Animal experimentation
title_short QUANTITATIVE EVALUATION OF EXPERIMENTAL BONE REGENERATION USING INDENTATION TESTS
title_full QUANTITATIVE EVALUATION OF EXPERIMENTAL BONE REGENERATION USING INDENTATION TESTS
title_fullStr QUANTITATIVE EVALUATION OF EXPERIMENTAL BONE REGENERATION USING INDENTATION TESTS
title_full_unstemmed QUANTITATIVE EVALUATION OF EXPERIMENTAL BONE REGENERATION USING INDENTATION TESTS
title_sort QUANTITATIVE EVALUATION OF EXPERIMENTAL BONE REGENERATION USING INDENTATION TESTS
author Vidotto,Valéria Trombini
author_facet Vidotto,Valéria Trombini
Batista,Nilza Alzira
Mariolani,José Ricardo Lenzi
Belangero,William Dias
author_role author
author2 Batista,Nilza Alzira
Mariolani,José Ricardo Lenzi
Belangero,William Dias
author2_role author
author
author
dc.contributor.author.fl_str_mv Vidotto,Valéria Trombini
Batista,Nilza Alzira
Mariolani,José Ricardo Lenzi
Belangero,William Dias
dc.subject.por.fl_str_mv Bone regeneration
Hardness tests
Animal experimentation
topic Bone regeneration
Hardness tests
Animal experimentation
description ABSTRACT Objectives: To determine whether the macroindentation test can be applied to quantitatively assess bone regeneration. Methods: A 3.2 mm diameter transverse monocortical defect was created on the medial aspect of both proximal metaphyses of the tibia of male Unib-WH rats. For the macroindentation tests, we used 5.00 mm diameter indenters with a 3.2 mm tip. Defect testing was performed 1 to 12 weeks following the surgical procedures to compare the hardness of the newly developed tissue over the 12-week study period. Additional histological, morphological and physical/chemical data were obtained by optical and electronic microscopy, Raman, and energy dispersive x-ray spectrometry (EDS). Results: The mean indentation forces increased in a time-dependent manner from 4 to 12 weeks (p<0.001). Tests performed with the 5.0 mm diameter tip were not able to measure the indentation forces in the first week after the procedure. Moreover, in the second postoperative week indentation forces and the newly formed tissue within the spinal canal were greater than those measured in the fourth and eighth weeks. Conclusions: The macroindentation test can be used to quantitatively assess bone regeneration in experimental studies. The choice of indenter tip diameter should consider the study design. Level of Evidence II, Diagnostic Studies.
publishDate 2017
dc.date.none.fl_str_mv 2017-04-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-78522017000200071
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-78522017000200071
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/1413-785220172502164015
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv ATHA EDITORA
publisher.none.fl_str_mv ATHA EDITORA
dc.source.none.fl_str_mv Acta Ortopédica Brasileira v.25 n.2 2017
reponame:Acta Ortopédica Brasileira (Online)
instname:Sociedade Brasileira de Ortopedia e Traumatologia (SBOT)
instacron:SBOT
instname_str Sociedade Brasileira de Ortopedia e Traumatologia (SBOT)
instacron_str SBOT
institution SBOT
reponame_str Acta Ortopédica Brasileira (Online)
collection Acta Ortopédica Brasileira (Online)
repository.name.fl_str_mv Acta Ortopédica Brasileira (Online) - Sociedade Brasileira de Ortopedia e Traumatologia (SBOT)
repository.mail.fl_str_mv 1atha@uol.com.br||actaortopedicabrasileira@uol.com.br
_version_ 1752122275617832960