Unfractionated heparin and mechanical thromboprophylaxis in hip arthroplasty
Autor(a) principal: | |
---|---|
Data de Publicação: | 2015 |
Outros Autores: | , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Acta Ortopédica Brasileira (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-78522015000400208 |
Resumo: | OBJECTIVE: To evaluate the efficacy and safety of unfractionated heparin associated with mechanical prophylaxis as a method for preventing venous thromboembolism in hip arthroplasty. METHOD: We retrospectively reviewed the records of 181 hip arthroplasties out of 216 consecutive cases performed over a period of 39 months in our hospital. We excluded 35 cases due to non-adherence to the standardized method of thromboprophylaxis or loss to follow-up. All arthroplasties evaluated completed one-year follow-up after surgery with five consultations at predefined periods. Efficacy of the proposed method was evaluated by the occurrence of symptomatic venous thromboembolism confirmed by specific tests and safety was determined by the lack of occurrence of major bleeding according to criteria established by the International Society on Thrombosis and Haemostasis. RESULTS: There were four cases of symptomatic venous thromboembolism (2.2%), with three cases of deep vein thrombosis (1.65%) and one case of pulmonary embolism (0.55%). We found one case of severe bleeding (0.55%). CONCLUSION: Unfractionated heparin associated with mechanical prophylaxis proved to be an effective and safe method for preventing venous thromboembolism in patients undergoing hip arthroplasty, presenting rates of thromboembolic complications and major bleeding within the range reported with other methods currently used of thromboprophylaxis. Level of Evidence IV, Case Series |
id |
SBOT-1_52d8fb00b345128461946ab88b4de8c0 |
---|---|
oai_identifier_str |
oai:scielo:S1413-78522015000400208 |
network_acronym_str |
SBOT-1 |
network_name_str |
Acta Ortopédica Brasileira (Online) |
repository_id_str |
|
spelling |
Unfractionated heparin and mechanical thromboprophylaxis in hip arthroplastyVenous thrombosisPulmonary embolismArthroplasty, replacement, hipHemorrhageHeparin OBJECTIVE: To evaluate the efficacy and safety of unfractionated heparin associated with mechanical prophylaxis as a method for preventing venous thromboembolism in hip arthroplasty. METHOD: We retrospectively reviewed the records of 181 hip arthroplasties out of 216 consecutive cases performed over a period of 39 months in our hospital. We excluded 35 cases due to non-adherence to the standardized method of thromboprophylaxis or loss to follow-up. All arthroplasties evaluated completed one-year follow-up after surgery with five consultations at predefined periods. Efficacy of the proposed method was evaluated by the occurrence of symptomatic venous thromboembolism confirmed by specific tests and safety was determined by the lack of occurrence of major bleeding according to criteria established by the International Society on Thrombosis and Haemostasis. RESULTS: There were four cases of symptomatic venous thromboembolism (2.2%), with three cases of deep vein thrombosis (1.65%) and one case of pulmonary embolism (0.55%). We found one case of severe bleeding (0.55%). CONCLUSION: Unfractionated heparin associated with mechanical prophylaxis proved to be an effective and safe method for preventing venous thromboembolism in patients undergoing hip arthroplasty, presenting rates of thromboembolic complications and major bleeding within the range reported with other methods currently used of thromboprophylaxis. Level of Evidence IV, Case Series ATHA EDITORA2015-08-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-78522015000400208Acta Ortopédica Brasileira v.23 n.4 2015reponame:Acta Ortopédica Brasileira (Online)instname:Sociedade Brasileira de Ortopedia e Traumatologia (SBOT)instacron:SBOT10.1590/1413-785220152304144314info:eu-repo/semantics/openAccessGarcia,Flávio LuísMarins,Murilo Humberto TobiasRaddi,Thiago BortolettoPicado,Celso Hermínio Ferrazeng2015-08-04T00:00:00Zoai:scielo:S1413-78522015000400208Revistahttp://www.actaortopedica.com.br/https://old.scielo.br/oai/scielo-oai.php1atha@uol.com.br||actaortopedicabrasileira@uol.com.br1809-44061413-7852opendoar:2015-08-04T00:00Acta Ortopédica Brasileira (Online) - Sociedade Brasileira de Ortopedia e Traumatologia (SBOT)false |
dc.title.none.fl_str_mv |
Unfractionated heparin and mechanical thromboprophylaxis in hip arthroplasty |
title |
Unfractionated heparin and mechanical thromboprophylaxis in hip arthroplasty |
spellingShingle |
Unfractionated heparin and mechanical thromboprophylaxis in hip arthroplasty Garcia,Flávio Luís Venous thrombosis Pulmonary embolism Arthroplasty, replacement, hip Hemorrhage Heparin |
title_short |
Unfractionated heparin and mechanical thromboprophylaxis in hip arthroplasty |
title_full |
Unfractionated heparin and mechanical thromboprophylaxis in hip arthroplasty |
title_fullStr |
Unfractionated heparin and mechanical thromboprophylaxis in hip arthroplasty |
title_full_unstemmed |
Unfractionated heparin and mechanical thromboprophylaxis in hip arthroplasty |
title_sort |
Unfractionated heparin and mechanical thromboprophylaxis in hip arthroplasty |
author |
Garcia,Flávio Luís |
author_facet |
Garcia,Flávio Luís Marins,Murilo Humberto Tobias Raddi,Thiago Bortoletto Picado,Celso Hermínio Ferraz |
author_role |
author |
author2 |
Marins,Murilo Humberto Tobias Raddi,Thiago Bortoletto Picado,Celso Hermínio Ferraz |
author2_role |
author author author |
dc.contributor.author.fl_str_mv |
Garcia,Flávio Luís Marins,Murilo Humberto Tobias Raddi,Thiago Bortoletto Picado,Celso Hermínio Ferraz |
dc.subject.por.fl_str_mv |
Venous thrombosis Pulmonary embolism Arthroplasty, replacement, hip Hemorrhage Heparin |
topic |
Venous thrombosis Pulmonary embolism Arthroplasty, replacement, hip Hemorrhage Heparin |
description |
OBJECTIVE: To evaluate the efficacy and safety of unfractionated heparin associated with mechanical prophylaxis as a method for preventing venous thromboembolism in hip arthroplasty. METHOD: We retrospectively reviewed the records of 181 hip arthroplasties out of 216 consecutive cases performed over a period of 39 months in our hospital. We excluded 35 cases due to non-adherence to the standardized method of thromboprophylaxis or loss to follow-up. All arthroplasties evaluated completed one-year follow-up after surgery with five consultations at predefined periods. Efficacy of the proposed method was evaluated by the occurrence of symptomatic venous thromboembolism confirmed by specific tests and safety was determined by the lack of occurrence of major bleeding according to criteria established by the International Society on Thrombosis and Haemostasis. RESULTS: There were four cases of symptomatic venous thromboembolism (2.2%), with three cases of deep vein thrombosis (1.65%) and one case of pulmonary embolism (0.55%). We found one case of severe bleeding (0.55%). CONCLUSION: Unfractionated heparin associated with mechanical prophylaxis proved to be an effective and safe method for preventing venous thromboembolism in patients undergoing hip arthroplasty, presenting rates of thromboembolic complications and major bleeding within the range reported with other methods currently used of thromboprophylaxis. Level of Evidence IV, Case Series |
publishDate |
2015 |
dc.date.none.fl_str_mv |
2015-08-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-78522015000400208 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-78522015000400208 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/1413-785220152304144314 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
ATHA EDITORA |
publisher.none.fl_str_mv |
ATHA EDITORA |
dc.source.none.fl_str_mv |
Acta Ortopédica Brasileira v.23 n.4 2015 reponame:Acta Ortopédica Brasileira (Online) instname:Sociedade Brasileira de Ortopedia e Traumatologia (SBOT) instacron:SBOT |
instname_str |
Sociedade Brasileira de Ortopedia e Traumatologia (SBOT) |
instacron_str |
SBOT |
institution |
SBOT |
reponame_str |
Acta Ortopédica Brasileira (Online) |
collection |
Acta Ortopédica Brasileira (Online) |
repository.name.fl_str_mv |
Acta Ortopédica Brasileira (Online) - Sociedade Brasileira de Ortopedia e Traumatologia (SBOT) |
repository.mail.fl_str_mv |
1atha@uol.com.br||actaortopedicabrasileira@uol.com.br |
_version_ |
1752122275166945280 |