COMPARISON OF BICONDYLAR TIBIAL PLATEAU FRACTURES WITH DOUBLE OR SINGLE LATERAL LOCKED PLATE
Autor(a) principal: | |
---|---|
Data de Publicação: | 2020 |
Outros Autores: | , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Acta Ortopédica Brasileira (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-78522020000400182 |
Resumo: | ABSTRACT Objective: To compare postoperative radiographic outcomes of Schatzker type V and VI tibial plateau fractures treated with double-plate or single lateral locked plate. Methods: Sixty-three patients operated from December 2011 to February 2016 were selected, 47 from the double-plate group and 16 from the single lateral locked plate group. Minimum follow-up for all patients was 6 months. Fracture reduction evaluation was based on radiographic parameters: joint reduction, sagittal alignment, coronal alignment, and condylar width. Results: Radiographic evaluation showed no statistical difference in the immediate or late postoperative periods. Conclusion: Despite the reduced sample, this study is aligned with current results published in the medical literature. The severity of Schatzker type V and VI tibial plateau fractures can be minimized by the correct indication for the implant regarding fracture morphology. Level of Evidence III, Retrospective comparative study. |
id |
SBOT-1_886342c2deae34dfeaa57dbe3b14f616 |
---|---|
oai_identifier_str |
oai:scielo:S1413-78522020000400182 |
network_acronym_str |
SBOT-1 |
network_name_str |
Acta Ortopédica Brasileira (Online) |
repository_id_str |
|
spelling |
COMPARISON OF BICONDYLAR TIBIAL PLATEAU FRACTURES WITH DOUBLE OR SINGLE LATERAL LOCKED PLATETibial Fractures. Fracture FixationInternal. Orthopedic Fixation DevicesABSTRACT Objective: To compare postoperative radiographic outcomes of Schatzker type V and VI tibial plateau fractures treated with double-plate or single lateral locked plate. Methods: Sixty-three patients operated from December 2011 to February 2016 were selected, 47 from the double-plate group and 16 from the single lateral locked plate group. Minimum follow-up for all patients was 6 months. Fracture reduction evaluation was based on radiographic parameters: joint reduction, sagittal alignment, coronal alignment, and condylar width. Results: Radiographic evaluation showed no statistical difference in the immediate or late postoperative periods. Conclusion: Despite the reduced sample, this study is aligned with current results published in the medical literature. The severity of Schatzker type V and VI tibial plateau fractures can be minimized by the correct indication for the implant regarding fracture morphology. Level of Evidence III, Retrospective comparative study.ATHA EDITORA2020-08-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-78522020000400182Acta Ortopédica Brasileira v.28 n.4 2020reponame:Acta Ortopédica Brasileira (Online)instname:Sociedade Brasileira de Ortopedia e Traumatologia (SBOT)instacron:SBOT10.1590/1413-785220202804233122info:eu-repo/semantics/openAccessArouca,Matheus ManoloCosta,Guilherme Henrique Ricardo daLeonhardt,Marcos CamargoBarbosa,DennisSilva,Jorge dos SantosKojima,Kodi Edsoneng2020-10-14T00:00:00Zoai:scielo:S1413-78522020000400182Revistahttp://www.actaortopedica.com.br/https://old.scielo.br/oai/scielo-oai.php1atha@uol.com.br||actaortopedicabrasileira@uol.com.br1809-44061413-7852opendoar:2020-10-14T00:00Acta Ortopédica Brasileira (Online) - Sociedade Brasileira de Ortopedia e Traumatologia (SBOT)false |
dc.title.none.fl_str_mv |
COMPARISON OF BICONDYLAR TIBIAL PLATEAU FRACTURES WITH DOUBLE OR SINGLE LATERAL LOCKED PLATE |
title |
COMPARISON OF BICONDYLAR TIBIAL PLATEAU FRACTURES WITH DOUBLE OR SINGLE LATERAL LOCKED PLATE |
spellingShingle |
COMPARISON OF BICONDYLAR TIBIAL PLATEAU FRACTURES WITH DOUBLE OR SINGLE LATERAL LOCKED PLATE Arouca,Matheus Manolo Tibial Fractures. Fracture Fixation Internal. Orthopedic Fixation Devices |
title_short |
COMPARISON OF BICONDYLAR TIBIAL PLATEAU FRACTURES WITH DOUBLE OR SINGLE LATERAL LOCKED PLATE |
title_full |
COMPARISON OF BICONDYLAR TIBIAL PLATEAU FRACTURES WITH DOUBLE OR SINGLE LATERAL LOCKED PLATE |
title_fullStr |
COMPARISON OF BICONDYLAR TIBIAL PLATEAU FRACTURES WITH DOUBLE OR SINGLE LATERAL LOCKED PLATE |
title_full_unstemmed |
COMPARISON OF BICONDYLAR TIBIAL PLATEAU FRACTURES WITH DOUBLE OR SINGLE LATERAL LOCKED PLATE |
title_sort |
COMPARISON OF BICONDYLAR TIBIAL PLATEAU FRACTURES WITH DOUBLE OR SINGLE LATERAL LOCKED PLATE |
author |
Arouca,Matheus Manolo |
author_facet |
Arouca,Matheus Manolo Costa,Guilherme Henrique Ricardo da Leonhardt,Marcos Camargo Barbosa,Dennis Silva,Jorge dos Santos Kojima,Kodi Edson |
author_role |
author |
author2 |
Costa,Guilherme Henrique Ricardo da Leonhardt,Marcos Camargo Barbosa,Dennis Silva,Jorge dos Santos Kojima,Kodi Edson |
author2_role |
author author author author author |
dc.contributor.author.fl_str_mv |
Arouca,Matheus Manolo Costa,Guilherme Henrique Ricardo da Leonhardt,Marcos Camargo Barbosa,Dennis Silva,Jorge dos Santos Kojima,Kodi Edson |
dc.subject.por.fl_str_mv |
Tibial Fractures. Fracture Fixation Internal. Orthopedic Fixation Devices |
topic |
Tibial Fractures. Fracture Fixation Internal. Orthopedic Fixation Devices |
description |
ABSTRACT Objective: To compare postoperative radiographic outcomes of Schatzker type V and VI tibial plateau fractures treated with double-plate or single lateral locked plate. Methods: Sixty-three patients operated from December 2011 to February 2016 were selected, 47 from the double-plate group and 16 from the single lateral locked plate group. Minimum follow-up for all patients was 6 months. Fracture reduction evaluation was based on radiographic parameters: joint reduction, sagittal alignment, coronal alignment, and condylar width. Results: Radiographic evaluation showed no statistical difference in the immediate or late postoperative periods. Conclusion: Despite the reduced sample, this study is aligned with current results published in the medical literature. The severity of Schatzker type V and VI tibial plateau fractures can be minimized by the correct indication for the implant regarding fracture morphology. Level of Evidence III, Retrospective comparative study. |
publishDate |
2020 |
dc.date.none.fl_str_mv |
2020-08-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-78522020000400182 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-78522020000400182 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/1413-785220202804233122 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
ATHA EDITORA |
publisher.none.fl_str_mv |
ATHA EDITORA |
dc.source.none.fl_str_mv |
Acta Ortopédica Brasileira v.28 n.4 2020 reponame:Acta Ortopédica Brasileira (Online) instname:Sociedade Brasileira de Ortopedia e Traumatologia (SBOT) instacron:SBOT |
instname_str |
Sociedade Brasileira de Ortopedia e Traumatologia (SBOT) |
instacron_str |
SBOT |
institution |
SBOT |
reponame_str |
Acta Ortopédica Brasileira (Online) |
collection |
Acta Ortopédica Brasileira (Online) |
repository.name.fl_str_mv |
Acta Ortopédica Brasileira (Online) - Sociedade Brasileira de Ortopedia e Traumatologia (SBOT) |
repository.mail.fl_str_mv |
1atha@uol.com.br||actaortopedicabrasileira@uol.com.br |
_version_ |
1752122276558405632 |