COMPARISON OF BICONDYLAR TIBIAL PLATEAU FRACTURES WITH DOUBLE OR SINGLE LATERAL LOCKED PLATE

Detalhes bibliográficos
Autor(a) principal: Arouca,Matheus Manolo
Data de Publicação: 2020
Outros Autores: Costa,Guilherme Henrique Ricardo da, Leonhardt,Marcos Camargo, Barbosa,Dennis, Silva,Jorge dos Santos, Kojima,Kodi Edson
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Acta Ortopédica Brasileira (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-78522020000400182
Resumo: ABSTRACT Objective: To compare postoperative radiographic outcomes of Schatzker type V and VI tibial plateau fractures treated with double-plate or single lateral locked plate. Methods: Sixty-three patients operated from December 2011 to February 2016 were selected, 47 from the double-plate group and 16 from the single lateral locked plate group. Minimum follow-up for all patients was 6 months. Fracture reduction evaluation was based on radiographic parameters: joint reduction, sagittal alignment, coronal alignment, and condylar width. Results: Radiographic evaluation showed no statistical difference in the immediate or late postoperative periods. Conclusion: Despite the reduced sample, this study is aligned with current results published in the medical literature. The severity of Schatzker type V and VI tibial plateau fractures can be minimized by the correct indication for the implant regarding fracture morphology. Level of Evidence III, Retrospective comparative study.
id SBOT-1_886342c2deae34dfeaa57dbe3b14f616
oai_identifier_str oai:scielo:S1413-78522020000400182
network_acronym_str SBOT-1
network_name_str Acta Ortopédica Brasileira (Online)
repository_id_str
spelling COMPARISON OF BICONDYLAR TIBIAL PLATEAU FRACTURES WITH DOUBLE OR SINGLE LATERAL LOCKED PLATETibial Fractures. Fracture FixationInternal. Orthopedic Fixation DevicesABSTRACT Objective: To compare postoperative radiographic outcomes of Schatzker type V and VI tibial plateau fractures treated with double-plate or single lateral locked plate. Methods: Sixty-three patients operated from December 2011 to February 2016 were selected, 47 from the double-plate group and 16 from the single lateral locked plate group. Minimum follow-up for all patients was 6 months. Fracture reduction evaluation was based on radiographic parameters: joint reduction, sagittal alignment, coronal alignment, and condylar width. Results: Radiographic evaluation showed no statistical difference in the immediate or late postoperative periods. Conclusion: Despite the reduced sample, this study is aligned with current results published in the medical literature. The severity of Schatzker type V and VI tibial plateau fractures can be minimized by the correct indication for the implant regarding fracture morphology. Level of Evidence III, Retrospective comparative study.ATHA EDITORA2020-08-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-78522020000400182Acta Ortopédica Brasileira v.28 n.4 2020reponame:Acta Ortopédica Brasileira (Online)instname:Sociedade Brasileira de Ortopedia e Traumatologia (SBOT)instacron:SBOT10.1590/1413-785220202804233122info:eu-repo/semantics/openAccessArouca,Matheus ManoloCosta,Guilherme Henrique Ricardo daLeonhardt,Marcos CamargoBarbosa,DennisSilva,Jorge dos SantosKojima,Kodi Edsoneng2020-10-14T00:00:00Zoai:scielo:S1413-78522020000400182Revistahttp://www.actaortopedica.com.br/https://old.scielo.br/oai/scielo-oai.php1atha@uol.com.br||actaortopedicabrasileira@uol.com.br1809-44061413-7852opendoar:2020-10-14T00:00Acta Ortopédica Brasileira (Online) - Sociedade Brasileira de Ortopedia e Traumatologia (SBOT)false
dc.title.none.fl_str_mv COMPARISON OF BICONDYLAR TIBIAL PLATEAU FRACTURES WITH DOUBLE OR SINGLE LATERAL LOCKED PLATE
title COMPARISON OF BICONDYLAR TIBIAL PLATEAU FRACTURES WITH DOUBLE OR SINGLE LATERAL LOCKED PLATE
spellingShingle COMPARISON OF BICONDYLAR TIBIAL PLATEAU FRACTURES WITH DOUBLE OR SINGLE LATERAL LOCKED PLATE
Arouca,Matheus Manolo
Tibial Fractures. Fracture Fixation
Internal. Orthopedic Fixation Devices
title_short COMPARISON OF BICONDYLAR TIBIAL PLATEAU FRACTURES WITH DOUBLE OR SINGLE LATERAL LOCKED PLATE
title_full COMPARISON OF BICONDYLAR TIBIAL PLATEAU FRACTURES WITH DOUBLE OR SINGLE LATERAL LOCKED PLATE
title_fullStr COMPARISON OF BICONDYLAR TIBIAL PLATEAU FRACTURES WITH DOUBLE OR SINGLE LATERAL LOCKED PLATE
title_full_unstemmed COMPARISON OF BICONDYLAR TIBIAL PLATEAU FRACTURES WITH DOUBLE OR SINGLE LATERAL LOCKED PLATE
title_sort COMPARISON OF BICONDYLAR TIBIAL PLATEAU FRACTURES WITH DOUBLE OR SINGLE LATERAL LOCKED PLATE
author Arouca,Matheus Manolo
author_facet Arouca,Matheus Manolo
Costa,Guilherme Henrique Ricardo da
Leonhardt,Marcos Camargo
Barbosa,Dennis
Silva,Jorge dos Santos
Kojima,Kodi Edson
author_role author
author2 Costa,Guilherme Henrique Ricardo da
Leonhardt,Marcos Camargo
Barbosa,Dennis
Silva,Jorge dos Santos
Kojima,Kodi Edson
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv Arouca,Matheus Manolo
Costa,Guilherme Henrique Ricardo da
Leonhardt,Marcos Camargo
Barbosa,Dennis
Silva,Jorge dos Santos
Kojima,Kodi Edson
dc.subject.por.fl_str_mv Tibial Fractures. Fracture Fixation
Internal. Orthopedic Fixation Devices
topic Tibial Fractures. Fracture Fixation
Internal. Orthopedic Fixation Devices
description ABSTRACT Objective: To compare postoperative radiographic outcomes of Schatzker type V and VI tibial plateau fractures treated with double-plate or single lateral locked plate. Methods: Sixty-three patients operated from December 2011 to February 2016 were selected, 47 from the double-plate group and 16 from the single lateral locked plate group. Minimum follow-up for all patients was 6 months. Fracture reduction evaluation was based on radiographic parameters: joint reduction, sagittal alignment, coronal alignment, and condylar width. Results: Radiographic evaluation showed no statistical difference in the immediate or late postoperative periods. Conclusion: Despite the reduced sample, this study is aligned with current results published in the medical literature. The severity of Schatzker type V and VI tibial plateau fractures can be minimized by the correct indication for the implant regarding fracture morphology. Level of Evidence III, Retrospective comparative study.
publishDate 2020
dc.date.none.fl_str_mv 2020-08-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-78522020000400182
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-78522020000400182
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/1413-785220202804233122
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv ATHA EDITORA
publisher.none.fl_str_mv ATHA EDITORA
dc.source.none.fl_str_mv Acta Ortopédica Brasileira v.28 n.4 2020
reponame:Acta Ortopédica Brasileira (Online)
instname:Sociedade Brasileira de Ortopedia e Traumatologia (SBOT)
instacron:SBOT
instname_str Sociedade Brasileira de Ortopedia e Traumatologia (SBOT)
instacron_str SBOT
institution SBOT
reponame_str Acta Ortopédica Brasileira (Online)
collection Acta Ortopédica Brasileira (Online)
repository.name.fl_str_mv Acta Ortopédica Brasileira (Online) - Sociedade Brasileira de Ortopedia e Traumatologia (SBOT)
repository.mail.fl_str_mv 1atha@uol.com.br||actaortopedicabrasileira@uol.com.br
_version_ 1752122276558405632