Analysis of stress induced by screws in the vertebral fixation system

Detalhes bibliográficos
Autor(a) principal: Fakhouri,Sarah Fakher
Data de Publicação: 2014
Outros Autores: Shimano,Marcos Massao, Araújo,Cleudmar Amaral de, Defino,Helton Luiz Aparecido, Shimano,Antônio Carlos
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Acta Ortopédica Brasileira (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-78522014000100017
Resumo: Objective: To compare, using photoelasticity, internal stress produced by USS II type screw with 5.2 and 6.2 mm external diameters, when submitted to three different pullout strengths. Methods: Two photoelastic models were especially made. The simulation was performed using loads of 1.8, 2.4 e 3.3 kgf.The fringe orders were evaluated around the screws. In all the models analyzed the shear stress were calculated. Results: Independently of the applied load, the smaller screw showed higher values of shear stress. Conclusion: According to the analysis performed, we observed that the place of highest stress was in the first thread of the lead, close to the head of the screws. Experimental study.
id SBOT-1_91ecda14b4240e65091f22777aabbaaf
oai_identifier_str oai:scielo:S1413-78522014000100017
network_acronym_str SBOT-1
network_name_str Acta Ortopédica Brasileira (Online)
repository_id_str
spelling Analysis of stress induced by screws in the vertebral fixation systemTensile strengthElasticityBiomechanicsQuantitative analysisQualitative analysis Objective: To compare, using photoelasticity, internal stress produced by USS II type screw with 5.2 and 6.2 mm external diameters, when submitted to three different pullout strengths. Methods: Two photoelastic models were especially made. The simulation was performed using loads of 1.8, 2.4 e 3.3 kgf.The fringe orders were evaluated around the screws. In all the models analyzed the shear stress were calculated. Results: Independently of the applied load, the smaller screw showed higher values of shear stress. Conclusion: According to the analysis performed, we observed that the place of highest stress was in the first thread of the lead, close to the head of the screws. Experimental study. ATHA EDITORA2014-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-78522014000100017Acta Ortopédica Brasileira v.22 n.1 2014reponame:Acta Ortopédica Brasileira (Online)instname:Sociedade Brasileira de Ortopedia e Traumatologia (SBOT)instacron:SBOT10.1590/S1413-78522014000100002info:eu-repo/semantics/openAccessFakhouri,Sarah FakherShimano,Marcos MassaoAraújo,Cleudmar Amaral deDefino,Helton Luiz AparecidoShimano,Antônio Carloseng2014-03-28T00:00:00Zoai:scielo:S1413-78522014000100017Revistahttp://www.actaortopedica.com.br/https://old.scielo.br/oai/scielo-oai.php1atha@uol.com.br||actaortopedicabrasileira@uol.com.br1809-44061413-7852opendoar:2014-03-28T00:00Acta Ortopédica Brasileira (Online) - Sociedade Brasileira de Ortopedia e Traumatologia (SBOT)false
dc.title.none.fl_str_mv Analysis of stress induced by screws in the vertebral fixation system
title Analysis of stress induced by screws in the vertebral fixation system
spellingShingle Analysis of stress induced by screws in the vertebral fixation system
Fakhouri,Sarah Fakher
Tensile strength
Elasticity
Biomechanics
Quantitative analysis
Qualitative analysis
title_short Analysis of stress induced by screws in the vertebral fixation system
title_full Analysis of stress induced by screws in the vertebral fixation system
title_fullStr Analysis of stress induced by screws in the vertebral fixation system
title_full_unstemmed Analysis of stress induced by screws in the vertebral fixation system
title_sort Analysis of stress induced by screws in the vertebral fixation system
author Fakhouri,Sarah Fakher
author_facet Fakhouri,Sarah Fakher
Shimano,Marcos Massao
Araújo,Cleudmar Amaral de
Defino,Helton Luiz Aparecido
Shimano,Antônio Carlos
author_role author
author2 Shimano,Marcos Massao
Araújo,Cleudmar Amaral de
Defino,Helton Luiz Aparecido
Shimano,Antônio Carlos
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Fakhouri,Sarah Fakher
Shimano,Marcos Massao
Araújo,Cleudmar Amaral de
Defino,Helton Luiz Aparecido
Shimano,Antônio Carlos
dc.subject.por.fl_str_mv Tensile strength
Elasticity
Biomechanics
Quantitative analysis
Qualitative analysis
topic Tensile strength
Elasticity
Biomechanics
Quantitative analysis
Qualitative analysis
description Objective: To compare, using photoelasticity, internal stress produced by USS II type screw with 5.2 and 6.2 mm external diameters, when submitted to three different pullout strengths. Methods: Two photoelastic models were especially made. The simulation was performed using loads of 1.8, 2.4 e 3.3 kgf.The fringe orders were evaluated around the screws. In all the models analyzed the shear stress were calculated. Results: Independently of the applied load, the smaller screw showed higher values of shear stress. Conclusion: According to the analysis performed, we observed that the place of highest stress was in the first thread of the lead, close to the head of the screws. Experimental study.
publishDate 2014
dc.date.none.fl_str_mv 2014-01-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-78522014000100017
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-78522014000100017
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S1413-78522014000100002
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv ATHA EDITORA
publisher.none.fl_str_mv ATHA EDITORA
dc.source.none.fl_str_mv Acta Ortopédica Brasileira v.22 n.1 2014
reponame:Acta Ortopédica Brasileira (Online)
instname:Sociedade Brasileira de Ortopedia e Traumatologia (SBOT)
instacron:SBOT
instname_str Sociedade Brasileira de Ortopedia e Traumatologia (SBOT)
instacron_str SBOT
institution SBOT
reponame_str Acta Ortopédica Brasileira (Online)
collection Acta Ortopédica Brasileira (Online)
repository.name.fl_str_mv Acta Ortopédica Brasileira (Online) - Sociedade Brasileira de Ortopedia e Traumatologia (SBOT)
repository.mail.fl_str_mv 1atha@uol.com.br||actaortopedicabrasileira@uol.com.br
_version_ 1752122274753806336