Subjective results of joint lavage and viscosupplementation in hemophilic arthropathy

Detalhes bibliográficos
Autor(a) principal: Rezende,Márcia Uchoa de
Data de Publicação: 2015
Outros Autores: Rosa,Thiago Bittencourt Carvalho, Pasqualin,Thiago, Frucchi,Renato, Okazaki,Erica, Villaça,Paula Ribeiro
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Acta Ortopédica Brasileira (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-78522015000300162
Resumo: OBJECTIVE: To assess whether joint lavage, viscosupplementation and triamcinolone improve joint pain, function and quality of life in patients with severe hemophilic arthropathy. METHODS: Fourteen patients with knee and/or ankle hemophilic arthritis with and without involvement of other joints underwent joint lavage and subsequent injection of hylan G-F20 and triamcinolone in all affected joints. The patients answered algo-functional questionnaires (Lequesne and WOMAC), visual analog scale for pain (VAS) and SF-36 preoperatively, and at one, three, six and twelve months postoperatively. RESULTS: Sixteen knees, 15 ankles, 8 elbows and one shoulder were treated in 14 patients. Six patients had musculoskeletal bleeding [ankle (1), leg muscle (2) and knees (4)] at 3 months affecting the results. Pain did not improve significantly. Function improved (WOMAC p=0.02 and Lequesne p=0.01). The physical component of SF-36 improved at all time points except at 3 months, with best results at one-year follow-up (baseline = 33.4; 1 month = 39.6; 3 months= 37.6; 6 months 39.6 and 1 year = 44.6; p < 0.001). CONCLUSION: Joint lavage followed by injection of triamcinolone and hylan G-F20 improves function and quality of life progressively up to a year, even in severe hemophilic arthropathy. Level of Evidence IV, Case Series.
id SBOT-1_cef86b514cad7671500695157ff0b4d8
oai_identifier_str oai:scielo:S1413-78522015000300162
network_acronym_str SBOT-1
network_name_str Acta Ortopédica Brasileira (Online)
repository_id_str
spelling Subjective results of joint lavage and viscosupplementation in hemophilic arthropathyHemophiliaOsteoarthritis, kneeHyaluronic acid/administration &amp; dosageHyaluronic acid/therapeutic use OBJECTIVE: To assess whether joint lavage, viscosupplementation and triamcinolone improve joint pain, function and quality of life in patients with severe hemophilic arthropathy. METHODS: Fourteen patients with knee and/or ankle hemophilic arthritis with and without involvement of other joints underwent joint lavage and subsequent injection of hylan G-F20 and triamcinolone in all affected joints. The patients answered algo-functional questionnaires (Lequesne and WOMAC), visual analog scale for pain (VAS) and SF-36 preoperatively, and at one, three, six and twelve months postoperatively. RESULTS: Sixteen knees, 15 ankles, 8 elbows and one shoulder were treated in 14 patients. Six patients had musculoskeletal bleeding [ankle (1), leg muscle (2) and knees (4)] at 3 months affecting the results. Pain did not improve significantly. Function improved (WOMAC p=0.02 and Lequesne p=0.01). The physical component of SF-36 improved at all time points except at 3 months, with best results at one-year follow-up (baseline = 33.4; 1 month = 39.6; 3 months= 37.6; 6 months 39.6 and 1 year = 44.6; p < 0.001). CONCLUSION: Joint lavage followed by injection of triamcinolone and hylan G-F20 improves function and quality of life progressively up to a year, even in severe hemophilic arthropathy. Level of Evidence IV, Case Series. ATHA EDITORA2015-06-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-78522015000300162Acta Ortopédica Brasileira v.23 n.3 2015reponame:Acta Ortopédica Brasileira (Online)instname:Sociedade Brasileira de Ortopedia e Traumatologia (SBOT)instacron:SBOT10.1590/1413-785220152302145885info:eu-repo/semantics/openAccessRezende,Márcia Uchoa deRosa,Thiago Bittencourt CarvalhoPasqualin,ThiagoFrucchi,RenatoOkazaki,EricaVillaça,Paula Ribeiroeng2015-07-27T00:00:00Zoai:scielo:S1413-78522015000300162Revistahttp://www.actaortopedica.com.br/https://old.scielo.br/oai/scielo-oai.php1atha@uol.com.br||actaortopedicabrasileira@uol.com.br1809-44061413-7852opendoar:2015-07-27T00:00Acta Ortopédica Brasileira (Online) - Sociedade Brasileira de Ortopedia e Traumatologia (SBOT)false
dc.title.none.fl_str_mv Subjective results of joint lavage and viscosupplementation in hemophilic arthropathy
title Subjective results of joint lavage and viscosupplementation in hemophilic arthropathy
spellingShingle Subjective results of joint lavage and viscosupplementation in hemophilic arthropathy
Rezende,Márcia Uchoa de
Hemophilia
Osteoarthritis, knee
Hyaluronic acid/administration &amp; dosage
Hyaluronic acid/therapeutic use
title_short Subjective results of joint lavage and viscosupplementation in hemophilic arthropathy
title_full Subjective results of joint lavage and viscosupplementation in hemophilic arthropathy
title_fullStr Subjective results of joint lavage and viscosupplementation in hemophilic arthropathy
title_full_unstemmed Subjective results of joint lavage and viscosupplementation in hemophilic arthropathy
title_sort Subjective results of joint lavage and viscosupplementation in hemophilic arthropathy
author Rezende,Márcia Uchoa de
author_facet Rezende,Márcia Uchoa de
Rosa,Thiago Bittencourt Carvalho
Pasqualin,Thiago
Frucchi,Renato
Okazaki,Erica
Villaça,Paula Ribeiro
author_role author
author2 Rosa,Thiago Bittencourt Carvalho
Pasqualin,Thiago
Frucchi,Renato
Okazaki,Erica
Villaça,Paula Ribeiro
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv Rezende,Márcia Uchoa de
Rosa,Thiago Bittencourt Carvalho
Pasqualin,Thiago
Frucchi,Renato
Okazaki,Erica
Villaça,Paula Ribeiro
dc.subject.por.fl_str_mv Hemophilia
Osteoarthritis, knee
Hyaluronic acid/administration &amp; dosage
Hyaluronic acid/therapeutic use
topic Hemophilia
Osteoarthritis, knee
Hyaluronic acid/administration &amp; dosage
Hyaluronic acid/therapeutic use
description OBJECTIVE: To assess whether joint lavage, viscosupplementation and triamcinolone improve joint pain, function and quality of life in patients with severe hemophilic arthropathy. METHODS: Fourteen patients with knee and/or ankle hemophilic arthritis with and without involvement of other joints underwent joint lavage and subsequent injection of hylan G-F20 and triamcinolone in all affected joints. The patients answered algo-functional questionnaires (Lequesne and WOMAC), visual analog scale for pain (VAS) and SF-36 preoperatively, and at one, three, six and twelve months postoperatively. RESULTS: Sixteen knees, 15 ankles, 8 elbows and one shoulder were treated in 14 patients. Six patients had musculoskeletal bleeding [ankle (1), leg muscle (2) and knees (4)] at 3 months affecting the results. Pain did not improve significantly. Function improved (WOMAC p=0.02 and Lequesne p=0.01). The physical component of SF-36 improved at all time points except at 3 months, with best results at one-year follow-up (baseline = 33.4; 1 month = 39.6; 3 months= 37.6; 6 months 39.6 and 1 year = 44.6; p < 0.001). CONCLUSION: Joint lavage followed by injection of triamcinolone and hylan G-F20 improves function and quality of life progressively up to a year, even in severe hemophilic arthropathy. Level of Evidence IV, Case Series.
publishDate 2015
dc.date.none.fl_str_mv 2015-06-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-78522015000300162
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-78522015000300162
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/1413-785220152302145885
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv ATHA EDITORA
publisher.none.fl_str_mv ATHA EDITORA
dc.source.none.fl_str_mv Acta Ortopédica Brasileira v.23 n.3 2015
reponame:Acta Ortopédica Brasileira (Online)
instname:Sociedade Brasileira de Ortopedia e Traumatologia (SBOT)
instacron:SBOT
instname_str Sociedade Brasileira de Ortopedia e Traumatologia (SBOT)
instacron_str SBOT
institution SBOT
reponame_str Acta Ortopédica Brasileira (Online)
collection Acta Ortopédica Brasileira (Online)
repository.name.fl_str_mv Acta Ortopédica Brasileira (Online) - Sociedade Brasileira de Ortopedia e Traumatologia (SBOT)
repository.mail.fl_str_mv 1atha@uol.com.br||actaortopedicabrasileira@uol.com.br
_version_ 1752122275155410944