APSI scaphoid hemiarthroplasty - long-term results
Autor(a) principal: | |
---|---|
Data de Publicação: | 2018 |
Outros Autores: | , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Revista Brasileira de Ortopedia (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-36162018000500582 |
Resumo: | ABSTRACT Objective: This study is aimed at evaluating the long-term results of proximal scaphoid hemiarthroplasty for post-traumatic avascular necrosis at this institution. Methods: Twelve patients who underwent this procedure were identified, and the mean follow-up time was 6.5 years (range: 5-8 years). All patients were male, with a mean age of 39 years (range: 28-55 years). In eight patients, the non-dominant limb was affected. The procedure was carried out through a dorsal approach and all patients underwent the same rehabilitation protocol. Cases were evaluated regarding complications, pain, range of motion, functional status (Mayo Wrist Score), and disability (QuickDASH Score). Results: No immediate post-operative complications, such as infection or dislocation of the implant, were observed. All patients presented with peri-implant osteolysis at follow-up, on a radiograph study. None of the patients was forced to abandon their previous professional activity, although about 50% required some type of adaptation at their workplace. The mean functional capacity was, according to the Mayo Wrist Score, of 67.5 points (range: 50-80), corresponding to a satisfactory degree of function. The QuickDASH disability score presented a mean of 25 (range: 3-47.7). Conclusion: The results of this series are in line with previously published studies about this technique. Hemiarthroplasty with a pyrocarbon implant is a safe technique for the treatment of post-fracture avascular necrosis of the scaphoid proximal pole. This technique allowed for satisfactory functional results at a mean follow-up of 6.5 years. |
id |
SBOT-2_259b84daa11124c082e03fbbb2a135eb |
---|---|
oai_identifier_str |
oai:scielo:S0102-36162018000500582 |
network_acronym_str |
SBOT-2 |
network_name_str |
Revista Brasileira de Ortopedia (Online) |
repository_id_str |
|
spelling |
APSI scaphoid hemiarthroplasty - long-term resultsHemiarthroplastyScaphoid boneNecrosisWristABSTRACT Objective: This study is aimed at evaluating the long-term results of proximal scaphoid hemiarthroplasty for post-traumatic avascular necrosis at this institution. Methods: Twelve patients who underwent this procedure were identified, and the mean follow-up time was 6.5 years (range: 5-8 years). All patients were male, with a mean age of 39 years (range: 28-55 years). In eight patients, the non-dominant limb was affected. The procedure was carried out through a dorsal approach and all patients underwent the same rehabilitation protocol. Cases were evaluated regarding complications, pain, range of motion, functional status (Mayo Wrist Score), and disability (QuickDASH Score). Results: No immediate post-operative complications, such as infection or dislocation of the implant, were observed. All patients presented with peri-implant osteolysis at follow-up, on a radiograph study. None of the patients was forced to abandon their previous professional activity, although about 50% required some type of adaptation at their workplace. The mean functional capacity was, according to the Mayo Wrist Score, of 67.5 points (range: 50-80), corresponding to a satisfactory degree of function. The QuickDASH disability score presented a mean of 25 (range: 3-47.7). Conclusion: The results of this series are in line with previously published studies about this technique. Hemiarthroplasty with a pyrocarbon implant is a safe technique for the treatment of post-fracture avascular necrosis of the scaphoid proximal pole. This technique allowed for satisfactory functional results at a mean follow-up of 6.5 years.Sociedade Brasileira de Ortopedia e Traumatologia2018-10-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-36162018000500582Revista Brasileira de Ortopedia v.53 n.5 2018reponame:Revista Brasileira de Ortopedia (Online)instname:Sociedade Brasileira de Ortopedia e Traumatologia (SBOT)instacron:SBOT10.1016/j.rboe.2018.07.011info:eu-repo/semantics/openAccessSantos,Filipe LimaFerreira,AndreiaGrazina,RitaSá,DavidCanela,PedroLemos,Ruieng2018-10-16T00:00:00Zoai:scielo:S0102-36162018000500582Revistahttp://www.rbo.org.br/https://old.scielo.br/oai/scielo-oai.php||rbo@sbot.org.br1982-43780102-3616opendoar:2018-10-16T00:00Revista Brasileira de Ortopedia (Online) - Sociedade Brasileira de Ortopedia e Traumatologia (SBOT)false |
dc.title.none.fl_str_mv |
APSI scaphoid hemiarthroplasty - long-term results |
title |
APSI scaphoid hemiarthroplasty - long-term results |
spellingShingle |
APSI scaphoid hemiarthroplasty - long-term results Santos,Filipe Lima Hemiarthroplasty Scaphoid bone Necrosis Wrist |
title_short |
APSI scaphoid hemiarthroplasty - long-term results |
title_full |
APSI scaphoid hemiarthroplasty - long-term results |
title_fullStr |
APSI scaphoid hemiarthroplasty - long-term results |
title_full_unstemmed |
APSI scaphoid hemiarthroplasty - long-term results |
title_sort |
APSI scaphoid hemiarthroplasty - long-term results |
author |
Santos,Filipe Lima |
author_facet |
Santos,Filipe Lima Ferreira,Andreia Grazina,Rita Sá,David Canela,Pedro Lemos,Rui |
author_role |
author |
author2 |
Ferreira,Andreia Grazina,Rita Sá,David Canela,Pedro Lemos,Rui |
author2_role |
author author author author author |
dc.contributor.author.fl_str_mv |
Santos,Filipe Lima Ferreira,Andreia Grazina,Rita Sá,David Canela,Pedro Lemos,Rui |
dc.subject.por.fl_str_mv |
Hemiarthroplasty Scaphoid bone Necrosis Wrist |
topic |
Hemiarthroplasty Scaphoid bone Necrosis Wrist |
description |
ABSTRACT Objective: This study is aimed at evaluating the long-term results of proximal scaphoid hemiarthroplasty for post-traumatic avascular necrosis at this institution. Methods: Twelve patients who underwent this procedure were identified, and the mean follow-up time was 6.5 years (range: 5-8 years). All patients were male, with a mean age of 39 years (range: 28-55 years). In eight patients, the non-dominant limb was affected. The procedure was carried out through a dorsal approach and all patients underwent the same rehabilitation protocol. Cases were evaluated regarding complications, pain, range of motion, functional status (Mayo Wrist Score), and disability (QuickDASH Score). Results: No immediate post-operative complications, such as infection or dislocation of the implant, were observed. All patients presented with peri-implant osteolysis at follow-up, on a radiograph study. None of the patients was forced to abandon their previous professional activity, although about 50% required some type of adaptation at their workplace. The mean functional capacity was, according to the Mayo Wrist Score, of 67.5 points (range: 50-80), corresponding to a satisfactory degree of function. The QuickDASH disability score presented a mean of 25 (range: 3-47.7). Conclusion: The results of this series are in line with previously published studies about this technique. Hemiarthroplasty with a pyrocarbon implant is a safe technique for the treatment of post-fracture avascular necrosis of the scaphoid proximal pole. This technique allowed for satisfactory functional results at a mean follow-up of 6.5 years. |
publishDate |
2018 |
dc.date.none.fl_str_mv |
2018-10-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-36162018000500582 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-36162018000500582 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1016/j.rboe.2018.07.011 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira de Ortopedia e Traumatologia |
publisher.none.fl_str_mv |
Sociedade Brasileira de Ortopedia e Traumatologia |
dc.source.none.fl_str_mv |
Revista Brasileira de Ortopedia v.53 n.5 2018 reponame:Revista Brasileira de Ortopedia (Online) instname:Sociedade Brasileira de Ortopedia e Traumatologia (SBOT) instacron:SBOT |
instname_str |
Sociedade Brasileira de Ortopedia e Traumatologia (SBOT) |
instacron_str |
SBOT |
institution |
SBOT |
reponame_str |
Revista Brasileira de Ortopedia (Online) |
collection |
Revista Brasileira de Ortopedia (Online) |
repository.name.fl_str_mv |
Revista Brasileira de Ortopedia (Online) - Sociedade Brasileira de Ortopedia e Traumatologia (SBOT) |
repository.mail.fl_str_mv |
||rbo@sbot.org.br |
_version_ |
1752122361529761792 |