Twisted Plating - A Method of Distal Fibula Fixation
Autor(a) principal: | |
---|---|
Data de Publicação: | 2020 |
Outros Autores: | , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Revista Brasileira de Ortopedia (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-36162020000100033 |
Resumo: | Abstract Objective The literature entails various intramedullary and extramedullary methods for distal fibula fracture fixation; with no consensus yet over the ideal method of fixation. We have retrospectively analyzed the results of using a twisted and contoured 3.5 mm locking compression plate (LCP) as a posterior buttress plate. Methods Of the 62 cases with ankle fractures managed at our institute by the senior author from 1st January 2012 to 31st December 2015, 41 patients met our inclusion criteria (Danis-Weber types B and C). Results All 41 distal fibular fractures healed uneventfully, at a mean of 10.4 weeks (8-14 weeks) (Figs. 6, 7, 8 to 9) with no complications. The mean American Orthopaedic Foot & Ankle Society (AOFAS) score was 92.6 (86-100) at a mean follow-up of 31.5 months (14-61 months). Conclusions We have achieved excellent clinical and radiological outcomes using a twisted 3.5 mm LCP as a posterior buttress by combining the advantages of posterior antiglide plating and lateral LCP. |
id |
SBOT-2_30c976c3600cbbb36bf5a4ea631bdd60 |
---|---|
oai_identifier_str |
oai:scielo:S0102-36162020000100033 |
network_acronym_str |
SBOT-2 |
network_name_str |
Revista Brasileira de Ortopedia (Online) |
repository_id_str |
|
spelling |
Twisted Plating - A Method of Distal Fibula Fixationankle fracturesfracture fixation, internalfractures, bonefibulabone platesAbstract Objective The literature entails various intramedullary and extramedullary methods for distal fibula fracture fixation; with no consensus yet over the ideal method of fixation. We have retrospectively analyzed the results of using a twisted and contoured 3.5 mm locking compression plate (LCP) as a posterior buttress plate. Methods Of the 62 cases with ankle fractures managed at our institute by the senior author from 1st January 2012 to 31st December 2015, 41 patients met our inclusion criteria (Danis-Weber types B and C). Results All 41 distal fibular fractures healed uneventfully, at a mean of 10.4 weeks (8-14 weeks) (Figs. 6, 7, 8 to 9) with no complications. The mean American Orthopaedic Foot & Ankle Society (AOFAS) score was 92.6 (86-100) at a mean follow-up of 31.5 months (14-61 months). Conclusions We have achieved excellent clinical and radiological outcomes using a twisted 3.5 mm LCP as a posterior buttress by combining the advantages of posterior antiglide plating and lateral LCP.Sociedade Brasileira de Ortopedia e Traumatologia2020-02-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-36162020000100033Revista Brasileira de Ortopedia v.55 n.1 2020reponame:Revista Brasileira de Ortopedia (Online)instname:Sociedade Brasileira de Ortopedia e Traumatologia (SBOT)instacron:SBOT10.1055/s-0039-1700820info:eu-repo/semantics/openAccessAgarwala,SanjayMenon,AdityaBhadiyadra,Ravieng2020-03-27T00:00:00Zoai:scielo:S0102-36162020000100033Revistahttp://www.rbo.org.br/https://old.scielo.br/oai/scielo-oai.php||rbo@sbot.org.br1982-43780102-3616opendoar:2020-03-27T00:00Revista Brasileira de Ortopedia (Online) - Sociedade Brasileira de Ortopedia e Traumatologia (SBOT)false |
dc.title.none.fl_str_mv |
Twisted Plating - A Method of Distal Fibula Fixation |
title |
Twisted Plating - A Method of Distal Fibula Fixation |
spellingShingle |
Twisted Plating - A Method of Distal Fibula Fixation Agarwala,Sanjay ankle fractures fracture fixation, internal fractures, bone fibula bone plates |
title_short |
Twisted Plating - A Method of Distal Fibula Fixation |
title_full |
Twisted Plating - A Method of Distal Fibula Fixation |
title_fullStr |
Twisted Plating - A Method of Distal Fibula Fixation |
title_full_unstemmed |
Twisted Plating - A Method of Distal Fibula Fixation |
title_sort |
Twisted Plating - A Method of Distal Fibula Fixation |
author |
Agarwala,Sanjay |
author_facet |
Agarwala,Sanjay Menon,Aditya Bhadiyadra,Ravi |
author_role |
author |
author2 |
Menon,Aditya Bhadiyadra,Ravi |
author2_role |
author author |
dc.contributor.author.fl_str_mv |
Agarwala,Sanjay Menon,Aditya Bhadiyadra,Ravi |
dc.subject.por.fl_str_mv |
ankle fractures fracture fixation, internal fractures, bone fibula bone plates |
topic |
ankle fractures fracture fixation, internal fractures, bone fibula bone plates |
description |
Abstract Objective The literature entails various intramedullary and extramedullary methods for distal fibula fracture fixation; with no consensus yet over the ideal method of fixation. We have retrospectively analyzed the results of using a twisted and contoured 3.5 mm locking compression plate (LCP) as a posterior buttress plate. Methods Of the 62 cases with ankle fractures managed at our institute by the senior author from 1st January 2012 to 31st December 2015, 41 patients met our inclusion criteria (Danis-Weber types B and C). Results All 41 distal fibular fractures healed uneventfully, at a mean of 10.4 weeks (8-14 weeks) (Figs. 6, 7, 8 to 9) with no complications. The mean American Orthopaedic Foot & Ankle Society (AOFAS) score was 92.6 (86-100) at a mean follow-up of 31.5 months (14-61 months). Conclusions We have achieved excellent clinical and radiological outcomes using a twisted 3.5 mm LCP as a posterior buttress by combining the advantages of posterior antiglide plating and lateral LCP. |
publishDate |
2020 |
dc.date.none.fl_str_mv |
2020-02-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-36162020000100033 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-36162020000100033 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1055/s-0039-1700820 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira de Ortopedia e Traumatologia |
publisher.none.fl_str_mv |
Sociedade Brasileira de Ortopedia e Traumatologia |
dc.source.none.fl_str_mv |
Revista Brasileira de Ortopedia v.55 n.1 2020 reponame:Revista Brasileira de Ortopedia (Online) instname:Sociedade Brasileira de Ortopedia e Traumatologia (SBOT) instacron:SBOT |
instname_str |
Sociedade Brasileira de Ortopedia e Traumatologia (SBOT) |
instacron_str |
SBOT |
institution |
SBOT |
reponame_str |
Revista Brasileira de Ortopedia (Online) |
collection |
Revista Brasileira de Ortopedia (Online) |
repository.name.fl_str_mv |
Revista Brasileira de Ortopedia (Online) - Sociedade Brasileira de Ortopedia e Traumatologia (SBOT) |
repository.mail.fl_str_mv |
||rbo@sbot.org.br |
_version_ |
1752122362346602496 |