Resumo: Abstract Objective The literature entails various intramedullary and extramedullary methods for distal fibula fracture fixation; with no consensus yet over the ideal method of fixation. We have retrospectively analyzed the results of using a twisted and contoured 3.5 mm locking compression plate (LCP) as a posterior buttress plate. Methods Of the 62 cases with ankle fractures managed at our institute by the senior author from 1st January 2012 to 31st December 2015, 41 patients met our inclusion criteria (Danis-Weber types B and C). Results All 41 distal fibular fractures healed uneventfully, at a mean of 10.4 weeks (8-14 weeks) (Figs. 6, 7, 8 to 9) with no complications. The mean American Orthopaedic Foot & Ankle Society (AOFAS) score was 92.6 (86-100) at a mean follow-up of 31.5 months (14-61 months). Conclusions We have achieved excellent clinical and radiological outcomes using a twisted 3.5 mm LCP as a posterior buttress by combining the advantages of posterior antiglide plating and lateral LCP.
id SBOT-2_30c976c3600cbbb36bf5a4ea631bdd60
oai_identifier_str oai:scielo:S0102-36162020000100033
network_acronym_str SBOT-2
network_name_str Revista Brasileira de Ortopedia (Online)
repository_id_str
spelling Twisted Plating - A Method of Distal Fibula Fixationankle fracturesfracture fixation, internalfractures, bonefibulabone platesAbstract Objective The literature entails various intramedullary and extramedullary methods for distal fibula fracture fixation; with no consensus yet over the ideal method of fixation. We have retrospectively analyzed the results of using a twisted and contoured 3.5 mm locking compression plate (LCP) as a posterior buttress plate. Methods Of the 62 cases with ankle fractures managed at our institute by the senior author from 1st January 2012 to 31st December 2015, 41 patients met our inclusion criteria (Danis-Weber types B and C). Results All 41 distal fibular fractures healed uneventfully, at a mean of 10.4 weeks (8-14 weeks) (Figs. 6, 7, 8 to 9) with no complications. The mean American Orthopaedic Foot & Ankle Society (AOFAS) score was 92.6 (86-100) at a mean follow-up of 31.5 months (14-61 months). Conclusions We have achieved excellent clinical and radiological outcomes using a twisted 3.5 mm LCP as a posterior buttress by combining the advantages of posterior antiglide plating and lateral LCP.Sociedade Brasileira de Ortopedia e Traumatologia2020-02-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-36162020000100033Revista Brasileira de Ortopedia v.55 n.1 2020reponame:Revista Brasileira de Ortopedia (Online)instname:Sociedade Brasileira de Ortopedia e Traumatologia (SBOT)instacron:SBOT10.1055/s-0039-1700820info:eu-repo/semantics/openAccessAgarwala,SanjayMenon,AdityaBhadiyadra,Ravieng2020-03-27T00:00:00Zoai:scielo:S0102-36162020000100033Revistahttp://www.rbo.org.br/https://old.scielo.br/oai/scielo-oai.php||rbo@sbot.org.br1982-43780102-3616opendoar:2020-03-27T00:00Revista Brasileira de Ortopedia (Online) - Sociedade Brasileira de Ortopedia e Traumatologia (SBOT)false
dc.title.none.fl_str_mv Twisted Plating - A Method of Distal Fibula Fixation
title Twisted Plating - A Method of Distal Fibula Fixation
spellingShingle Twisted Plating - A Method of Distal Fibula Fixation
Agarwala,Sanjay
ankle fractures
fracture fixation, internal
fractures, bone
fibula
bone plates
title_short Twisted Plating - A Method of Distal Fibula Fixation
title_full Twisted Plating - A Method of Distal Fibula Fixation
title_fullStr Twisted Plating - A Method of Distal Fibula Fixation
title_full_unstemmed Twisted Plating - A Method of Distal Fibula Fixation
title_sort Twisted Plating - A Method of Distal Fibula Fixation
author Agarwala,Sanjay
author_facet Agarwala,Sanjay
Menon,Aditya
Bhadiyadra,Ravi
author_role author
author2 Menon,Aditya
Bhadiyadra,Ravi
author2_role author
author
dc.contributor.author.fl_str_mv Agarwala,Sanjay
Menon,Aditya
Bhadiyadra,Ravi
dc.subject.por.fl_str_mv ankle fractures
fracture fixation, internal
fractures, bone
fibula
bone plates
topic ankle fractures
fracture fixation, internal
fractures, bone
fibula
bone plates
description Abstract Objective The literature entails various intramedullary and extramedullary methods for distal fibula fracture fixation; with no consensus yet over the ideal method of fixation. We have retrospectively analyzed the results of using a twisted and contoured 3.5 mm locking compression plate (LCP) as a posterior buttress plate. Methods Of the 62 cases with ankle fractures managed at our institute by the senior author from 1st January 2012 to 31st December 2015, 41 patients met our inclusion criteria (Danis-Weber types B and C). Results All 41 distal fibular fractures healed uneventfully, at a mean of 10.4 weeks (8-14 weeks) (Figs. 6, 7, 8 to 9) with no complications. The mean American Orthopaedic Foot & Ankle Society (AOFAS) score was 92.6 (86-100) at a mean follow-up of 31.5 months (14-61 months). Conclusions We have achieved excellent clinical and radiological outcomes using a twisted 3.5 mm LCP as a posterior buttress by combining the advantages of posterior antiglide plating and lateral LCP.
publishDate 2020
dc.date.none.fl_str_mv 2020-02-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-36162020000100033
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-36162020000100033
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1055/s-0039-1700820
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Ortopedia e Traumatologia
publisher.none.fl_str_mv Sociedade Brasileira de Ortopedia e Traumatologia
dc.source.none.fl_str_mv Revista Brasileira de Ortopedia v.55 n.1 2020
reponame:Revista Brasileira de Ortopedia (Online)
instname:Sociedade Brasileira de Ortopedia e Traumatologia (SBOT)
instacron:SBOT
instname_str Sociedade Brasileira de Ortopedia e Traumatologia (SBOT)
instacron_str SBOT
institution SBOT
reponame_str Revista Brasileira de Ortopedia (Online)
collection Revista Brasileira de Ortopedia (Online)
repository.name.fl_str_mv Revista Brasileira de Ortopedia (Online) - Sociedade Brasileira de Ortopedia e Traumatologia (SBOT)
repository.mail.fl_str_mv ||rbo@sbot.org.br
_version_ 1752122362346602496