Intraoperative graft decontamination during ACL reconstruction surgery
Autor(a) principal: | |
---|---|
Data de Publicação: | 2020 |
Outros Autores: | , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Revista Brasileira de Ortopedia (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-36162020000400410 |
Resumo: | Abstract Objective To evaluate different decontaminants for tendon grafts, proposing an antiseptic protocol for contaminated grafts. Methods A total of 25 patients were tissue donors for the study. Each participant donated a 2.5-cm tendon sample, which was divided into 5 fragments with 5 mm each during anterior cruciate ligament (ACL) reconstruction surgery. The collected material was divided into 5 groups, totaling 125 samples. In total, four fragments of each patient were placed on the operating room floor for one minute for contamination, simulating the fall of the graft on the floor during surgery. The other fragment was immediately placed in a sterile container (group 1). One of the contaminated fragments was placed in the sterile container without being previously immersed in decontaminating solution (group 2). The remaining fragments were immersed for ten minutes in decontaminating solution: 0.5% chlorhexidine (group 3), 0.9% saline (group 4) and 0.55% ortho-phthalaldehyde (group 5), and, after this time, they were individually placed in a sterile container. The samples from the 5 groups were submitted to microbiological examination. Results Bacteria were detected in 26% of the total samples in the microbiological tests, and in group 1 there was no growth of microorganisms. In group 2, bacterial growth was observed in 16 samples. Considering the evaluation of test groups 3, 4 and 5, the percentage of decontamination was higher than the growth of microorganisms in the respective cultures. Conclusion The protocol suggested by the study showed that intraoperative graft decontamination is possible. |
id |
SBOT-2_4d4ea0d95dfbe123c3f4379856e14dda |
---|---|
oai_identifier_str |
oai:scielo:S0102-36162020000400410 |
network_acronym_str |
SBOT-2 |
network_name_str |
Revista Brasileira de Ortopedia (Online) |
repository_id_str |
|
spelling |
Intraoperative graft decontamination during ACL reconstruction surgeryautograftanterior cruciate ligamentdecontaminationAbstract Objective To evaluate different decontaminants for tendon grafts, proposing an antiseptic protocol for contaminated grafts. Methods A total of 25 patients were tissue donors for the study. Each participant donated a 2.5-cm tendon sample, which was divided into 5 fragments with 5 mm each during anterior cruciate ligament (ACL) reconstruction surgery. The collected material was divided into 5 groups, totaling 125 samples. In total, four fragments of each patient were placed on the operating room floor for one minute for contamination, simulating the fall of the graft on the floor during surgery. The other fragment was immediately placed in a sterile container (group 1). One of the contaminated fragments was placed in the sterile container without being previously immersed in decontaminating solution (group 2). The remaining fragments were immersed for ten minutes in decontaminating solution: 0.5% chlorhexidine (group 3), 0.9% saline (group 4) and 0.55% ortho-phthalaldehyde (group 5), and, after this time, they were individually placed in a sterile container. The samples from the 5 groups were submitted to microbiological examination. Results Bacteria were detected in 26% of the total samples in the microbiological tests, and in group 1 there was no growth of microorganisms. In group 2, bacterial growth was observed in 16 samples. Considering the evaluation of test groups 3, 4 and 5, the percentage of decontamination was higher than the growth of microorganisms in the respective cultures. Conclusion The protocol suggested by the study showed that intraoperative graft decontamination is possible.Sociedade Brasileira de Ortopedia e Traumatologia2020-08-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-36162020000400410Revista Brasileira de Ortopedia v.55 n.4 2020reponame:Revista Brasileira de Ortopedia (Online)instname:Sociedade Brasileira de Ortopedia e Traumatologia (SBOT)instacron:SBOT10.1055/s-0039-1700830info:eu-repo/semantics/openAccessLuciano,Roberto CunhaMacedo,Ígor SeverinoPereira,Rafael Henrique NavesPereira,Daniel BarrosLuciano,Dyego Vilelaeng2020-09-28T00:00:00Zoai:scielo:S0102-36162020000400410Revistahttp://www.rbo.org.br/https://old.scielo.br/oai/scielo-oai.php||rbo@sbot.org.br1982-43780102-3616opendoar:2020-09-28T00:00Revista Brasileira de Ortopedia (Online) - Sociedade Brasileira de Ortopedia e Traumatologia (SBOT)false |
dc.title.none.fl_str_mv |
Intraoperative graft decontamination during ACL reconstruction surgery |
title |
Intraoperative graft decontamination during ACL reconstruction surgery |
spellingShingle |
Intraoperative graft decontamination during ACL reconstruction surgery Luciano,Roberto Cunha autograft anterior cruciate ligament decontamination |
title_short |
Intraoperative graft decontamination during ACL reconstruction surgery |
title_full |
Intraoperative graft decontamination during ACL reconstruction surgery |
title_fullStr |
Intraoperative graft decontamination during ACL reconstruction surgery |
title_full_unstemmed |
Intraoperative graft decontamination during ACL reconstruction surgery |
title_sort |
Intraoperative graft decontamination during ACL reconstruction surgery |
author |
Luciano,Roberto Cunha |
author_facet |
Luciano,Roberto Cunha Macedo,Ígor Severino Pereira,Rafael Henrique Naves Pereira,Daniel Barros Luciano,Dyego Vilela |
author_role |
author |
author2 |
Macedo,Ígor Severino Pereira,Rafael Henrique Naves Pereira,Daniel Barros Luciano,Dyego Vilela |
author2_role |
author author author author |
dc.contributor.author.fl_str_mv |
Luciano,Roberto Cunha Macedo,Ígor Severino Pereira,Rafael Henrique Naves Pereira,Daniel Barros Luciano,Dyego Vilela |
dc.subject.por.fl_str_mv |
autograft anterior cruciate ligament decontamination |
topic |
autograft anterior cruciate ligament decontamination |
description |
Abstract Objective To evaluate different decontaminants for tendon grafts, proposing an antiseptic protocol for contaminated grafts. Methods A total of 25 patients were tissue donors for the study. Each participant donated a 2.5-cm tendon sample, which was divided into 5 fragments with 5 mm each during anterior cruciate ligament (ACL) reconstruction surgery. The collected material was divided into 5 groups, totaling 125 samples. In total, four fragments of each patient were placed on the operating room floor for one minute for contamination, simulating the fall of the graft on the floor during surgery. The other fragment was immediately placed in a sterile container (group 1). One of the contaminated fragments was placed in the sterile container without being previously immersed in decontaminating solution (group 2). The remaining fragments were immersed for ten minutes in decontaminating solution: 0.5% chlorhexidine (group 3), 0.9% saline (group 4) and 0.55% ortho-phthalaldehyde (group 5), and, after this time, they were individually placed in a sterile container. The samples from the 5 groups were submitted to microbiological examination. Results Bacteria were detected in 26% of the total samples in the microbiological tests, and in group 1 there was no growth of microorganisms. In group 2, bacterial growth was observed in 16 samples. Considering the evaluation of test groups 3, 4 and 5, the percentage of decontamination was higher than the growth of microorganisms in the respective cultures. Conclusion The protocol suggested by the study showed that intraoperative graft decontamination is possible. |
publishDate |
2020 |
dc.date.none.fl_str_mv |
2020-08-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-36162020000400410 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-36162020000400410 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1055/s-0039-1700830 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira de Ortopedia e Traumatologia |
publisher.none.fl_str_mv |
Sociedade Brasileira de Ortopedia e Traumatologia |
dc.source.none.fl_str_mv |
Revista Brasileira de Ortopedia v.55 n.4 2020 reponame:Revista Brasileira de Ortopedia (Online) instname:Sociedade Brasileira de Ortopedia e Traumatologia (SBOT) instacron:SBOT |
instname_str |
Sociedade Brasileira de Ortopedia e Traumatologia (SBOT) |
instacron_str |
SBOT |
institution |
SBOT |
reponame_str |
Revista Brasileira de Ortopedia (Online) |
collection |
Revista Brasileira de Ortopedia (Online) |
repository.name.fl_str_mv |
Revista Brasileira de Ortopedia (Online) - Sociedade Brasileira de Ortopedia e Traumatologia (SBOT) |
repository.mail.fl_str_mv |
||rbo@sbot.org.br |
_version_ |
1752122362452508672 |