Biomechanical evaluation between the modified Mason-Allen stitch and the locked double-tie stitch on the infraspinatus of sheep,

Detalhes bibliográficos
Autor(a) principal: Miyazaki,Alberto Naoki
Data de Publicação: 2014
Outros Autores: Fregoneze,Marcelo, Santos,Pedro Doneux, Silva,Luciana Andrade da, Sella,Guilherme do Val, Zanella,Luiz Antonio Zanotelli, Salvia,João Caron La, Checchia,Sergio Luiz
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Revista Brasileira de Ortopedia (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-36162014000600630
Resumo: Objectives:To evaluate and compare the in vitro biomechanical results from two stitches: the Mason-Allen stitch, as modified by Habermeyer; and the locked double-tie stitch developed at our service, on tendons of the infraspinatus muscle of sheep.Methods:Twenty tendons from the infraspinatus muscle of sheep were randomly divided into two groups: LDT, on which the locked double-tie stitch was performed; and MA, with the modified Mason-Allen stitch. The evaluation was performed in the mechanics laboratory, using a standard test machine with unidirectional traction, constant velocity of 20 mm per second and a 500 N load cell, without force cycling.Results:We observed that LDT was superior to MA, for the force needed to form spaces of both 5 mm (p = 0.01) and 10 mm (p = 0.002) and also for the maximum traction resistance (p = 0.003).Conclusion:We confirmed our hypothesis that LDT stitches are superior to MA stitches from a biomechanical point of view. This is a further stitching option for surgeons, when fragile and poorly vascularized tendons need to be sutured, and it improves the quality of fixation without increasing the "strangulation" and, consequently, the ischemic area.
id SBOT-2_b4512573be0e90761a21be8014a65d4c
oai_identifier_str oai:scielo:S0102-36162014000600630
network_acronym_str SBOT-2
network_name_str Revista Brasileira de Ortopedia (Online)
repository_id_str
spelling Biomechanical evaluation between the modified Mason-Allen stitch and the locked double-tie stitch on the infraspinatus of sheep,Suturing techniquesShoulderRotator cuffObjectives:To evaluate and compare the in vitro biomechanical results from two stitches: the Mason-Allen stitch, as modified by Habermeyer; and the locked double-tie stitch developed at our service, on tendons of the infraspinatus muscle of sheep.Methods:Twenty tendons from the infraspinatus muscle of sheep were randomly divided into two groups: LDT, on which the locked double-tie stitch was performed; and MA, with the modified Mason-Allen stitch. The evaluation was performed in the mechanics laboratory, using a standard test machine with unidirectional traction, constant velocity of 20 mm per second and a 500 N load cell, without force cycling.Results:We observed that LDT was superior to MA, for the force needed to form spaces of both 5 mm (p = 0.01) and 10 mm (p = 0.002) and also for the maximum traction resistance (p = 0.003).Conclusion:We confirmed our hypothesis that LDT stitches are superior to MA stitches from a biomechanical point of view. This is a further stitching option for surgeons, when fragile and poorly vascularized tendons need to be sutured, and it improves the quality of fixation without increasing the "strangulation" and, consequently, the ischemic area.Sociedade Brasileira de Ortopedia e Traumatologia2014-12-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-36162014000600630Revista Brasileira de Ortopedia v.49 n.6 2014reponame:Revista Brasileira de Ortopedia (Online)instname:Sociedade Brasileira de Ortopedia e Traumatologia (SBOT)instacron:SBOT10.1016/j.rboe.2014.10.001info:eu-repo/semantics/openAccessMiyazaki,Alberto NaokiFregoneze,MarceloSantos,Pedro DoneuxSilva,Luciana Andrade daSella,Guilherme do ValZanella,Luiz Antonio ZanotelliSalvia,João Caron LaChecchia,Sergio Luizeng2015-09-23T00:00:00Zoai:scielo:S0102-36162014000600630Revistahttp://www.rbo.org.br/https://old.scielo.br/oai/scielo-oai.php||rbo@sbot.org.br1982-43780102-3616opendoar:2015-09-23T00:00Revista Brasileira de Ortopedia (Online) - Sociedade Brasileira de Ortopedia e Traumatologia (SBOT)false
dc.title.none.fl_str_mv Biomechanical evaluation between the modified Mason-Allen stitch and the locked double-tie stitch on the infraspinatus of sheep,
title Biomechanical evaluation between the modified Mason-Allen stitch and the locked double-tie stitch on the infraspinatus of sheep,
spellingShingle Biomechanical evaluation between the modified Mason-Allen stitch and the locked double-tie stitch on the infraspinatus of sheep,
Miyazaki,Alberto Naoki
Suturing techniques
Shoulder
Rotator cuff
title_short Biomechanical evaluation between the modified Mason-Allen stitch and the locked double-tie stitch on the infraspinatus of sheep,
title_full Biomechanical evaluation between the modified Mason-Allen stitch and the locked double-tie stitch on the infraspinatus of sheep,
title_fullStr Biomechanical evaluation between the modified Mason-Allen stitch and the locked double-tie stitch on the infraspinatus of sheep,
title_full_unstemmed Biomechanical evaluation between the modified Mason-Allen stitch and the locked double-tie stitch on the infraspinatus of sheep,
title_sort Biomechanical evaluation between the modified Mason-Allen stitch and the locked double-tie stitch on the infraspinatus of sheep,
author Miyazaki,Alberto Naoki
author_facet Miyazaki,Alberto Naoki
Fregoneze,Marcelo
Santos,Pedro Doneux
Silva,Luciana Andrade da
Sella,Guilherme do Val
Zanella,Luiz Antonio Zanotelli
Salvia,João Caron La
Checchia,Sergio Luiz
author_role author
author2 Fregoneze,Marcelo
Santos,Pedro Doneux
Silva,Luciana Andrade da
Sella,Guilherme do Val
Zanella,Luiz Antonio Zanotelli
Salvia,João Caron La
Checchia,Sergio Luiz
author2_role author
author
author
author
author
author
author
dc.contributor.author.fl_str_mv Miyazaki,Alberto Naoki
Fregoneze,Marcelo
Santos,Pedro Doneux
Silva,Luciana Andrade da
Sella,Guilherme do Val
Zanella,Luiz Antonio Zanotelli
Salvia,João Caron La
Checchia,Sergio Luiz
dc.subject.por.fl_str_mv Suturing techniques
Shoulder
Rotator cuff
topic Suturing techniques
Shoulder
Rotator cuff
description Objectives:To evaluate and compare the in vitro biomechanical results from two stitches: the Mason-Allen stitch, as modified by Habermeyer; and the locked double-tie stitch developed at our service, on tendons of the infraspinatus muscle of sheep.Methods:Twenty tendons from the infraspinatus muscle of sheep were randomly divided into two groups: LDT, on which the locked double-tie stitch was performed; and MA, with the modified Mason-Allen stitch. The evaluation was performed in the mechanics laboratory, using a standard test machine with unidirectional traction, constant velocity of 20 mm per second and a 500 N load cell, without force cycling.Results:We observed that LDT was superior to MA, for the force needed to form spaces of both 5 mm (p = 0.01) and 10 mm (p = 0.002) and also for the maximum traction resistance (p = 0.003).Conclusion:We confirmed our hypothesis that LDT stitches are superior to MA stitches from a biomechanical point of view. This is a further stitching option for surgeons, when fragile and poorly vascularized tendons need to be sutured, and it improves the quality of fixation without increasing the "strangulation" and, consequently, the ischemic area.
publishDate 2014
dc.date.none.fl_str_mv 2014-12-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-36162014000600630
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-36162014000600630
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1016/j.rboe.2014.10.001
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Ortopedia e Traumatologia
publisher.none.fl_str_mv Sociedade Brasileira de Ortopedia e Traumatologia
dc.source.none.fl_str_mv Revista Brasileira de Ortopedia v.49 n.6 2014
reponame:Revista Brasileira de Ortopedia (Online)
instname:Sociedade Brasileira de Ortopedia e Traumatologia (SBOT)
instacron:SBOT
instname_str Sociedade Brasileira de Ortopedia e Traumatologia (SBOT)
instacron_str SBOT
institution SBOT
reponame_str Revista Brasileira de Ortopedia (Online)
collection Revista Brasileira de Ortopedia (Online)
repository.name.fl_str_mv Revista Brasileira de Ortopedia (Online) - Sociedade Brasileira de Ortopedia e Traumatologia (SBOT)
repository.mail.fl_str_mv ||rbo@sbot.org.br
_version_ 1752122359538515968