TRH stimulation test in patients with repeatedly elevated TSH and normal FT4
Autor(a) principal: | |
---|---|
Data de Publicação: | 2020 |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Jornal Brasileiro de Patologia e Medicina Laboratorial (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1676-24442020000100425 |
Resumo: | ABSTRACT Subclinical hypothyroidism (SCH) is defined by elevated thyroid-stimulating hormone (TSH) with normal free thyroxine (FT4). We aimed to evaluate the thyrotropin-releasing hormone (TRH) stimulation test in patients with repeatedly elevated TSH (up to 10 mIU/l) and normal FT4, but without apparent thyroid disease. Women with TSH > 4.5 and ≤ 10 mIU/l (in two measurements) and normal FT4 were selected. Women with a known non-thyroid cause of TSH elevation, those treated with anti-thyroid drugs, amiodarone, lithium, and those with a history of thyroidectomy, neck radiotherapy and 131I treatment were excluded. Seventy women had negative antithyroperoxidase antibodies. Ultrasonography revealed a eutopic thyroid, usual echogenicity, and a volume ≤ 15 ml, and they underwent the TRH stimulation test during initial evaluation. After stimulation with TRH, TSH > 30 mIU/l was observed in 38 women (expected response), while 32 women had TSH < 20 mIU/l (inadequate response). Age, basal TSH or thyroid volume did not differ between both groups, but FT4 concentrations were significantly lower in the first group. Follow-up was available for 66/70 women. Seven women developed a need for levothyroxine, all of them in the group with an adequate response to TRH [7/36 (19.4%) versus 0/30]. The results suggest that some cases of TSH elevation (even persistent) do not represent the early stage of thyroid insufficiency. |
id |
SBP-1_74c98ec17696e23d4f2224dd3a8ac955 |
---|---|
oai_identifier_str |
oai:scielo:S1676-24442020000100425 |
network_acronym_str |
SBP-1 |
network_name_str |
Jornal Brasileiro de Patologia e Medicina Laboratorial (Online) |
repository_id_str |
|
spelling |
TRH stimulation test in patients with repeatedly elevated TSH and normal FT4subclinical hypothyroidismthyrotropin-releasing hormonethyroid function testsABSTRACT Subclinical hypothyroidism (SCH) is defined by elevated thyroid-stimulating hormone (TSH) with normal free thyroxine (FT4). We aimed to evaluate the thyrotropin-releasing hormone (TRH) stimulation test in patients with repeatedly elevated TSH (up to 10 mIU/l) and normal FT4, but without apparent thyroid disease. Women with TSH > 4.5 and ≤ 10 mIU/l (in two measurements) and normal FT4 were selected. Women with a known non-thyroid cause of TSH elevation, those treated with anti-thyroid drugs, amiodarone, lithium, and those with a history of thyroidectomy, neck radiotherapy and 131I treatment were excluded. Seventy women had negative antithyroperoxidase antibodies. Ultrasonography revealed a eutopic thyroid, usual echogenicity, and a volume ≤ 15 ml, and they underwent the TRH stimulation test during initial evaluation. After stimulation with TRH, TSH > 30 mIU/l was observed in 38 women (expected response), while 32 women had TSH < 20 mIU/l (inadequate response). Age, basal TSH or thyroid volume did not differ between both groups, but FT4 concentrations were significantly lower in the first group. Follow-up was available for 66/70 women. Seven women developed a need for levothyroxine, all of them in the group with an adequate response to TRH [7/36 (19.4%) versus 0/30]. The results suggest that some cases of TSH elevation (even persistent) do not represent the early stage of thyroid insufficiency.Sociedade Brasileira de Patologia Clínica2020-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1676-24442020000100425Jornal Brasileiro de Patologia e Medicina Laboratorial v.56 2020reponame:Jornal Brasileiro de Patologia e Medicina Laboratorial (Online)instname:Sociedade Brasileira de Patologia (SBP)instacron:SBP10.5935/1676-2444.20200043info:eu-repo/semantics/openAccessRosario,Pedro Weslleyeng2020-06-29T00:00:00Zoai:scielo:S1676-24442020000100425Revistahttp://www.scielo.br/jbpmlhttps://old.scielo.br/oai/scielo-oai.php||jbpml@sbpc.org.br1678-47741676-2444opendoar:2020-06-29T00:00Jornal Brasileiro de Patologia e Medicina Laboratorial (Online) - Sociedade Brasileira de Patologia (SBP)false |
dc.title.none.fl_str_mv |
TRH stimulation test in patients with repeatedly elevated TSH and normal FT4 |
title |
TRH stimulation test in patients with repeatedly elevated TSH and normal FT4 |
spellingShingle |
TRH stimulation test in patients with repeatedly elevated TSH and normal FT4 Rosario,Pedro Weslley subclinical hypothyroidism thyrotropin-releasing hormone thyroid function tests |
title_short |
TRH stimulation test in patients with repeatedly elevated TSH and normal FT4 |
title_full |
TRH stimulation test in patients with repeatedly elevated TSH and normal FT4 |
title_fullStr |
TRH stimulation test in patients with repeatedly elevated TSH and normal FT4 |
title_full_unstemmed |
TRH stimulation test in patients with repeatedly elevated TSH and normal FT4 |
title_sort |
TRH stimulation test in patients with repeatedly elevated TSH and normal FT4 |
author |
Rosario,Pedro Weslley |
author_facet |
Rosario,Pedro Weslley |
author_role |
author |
dc.contributor.author.fl_str_mv |
Rosario,Pedro Weslley |
dc.subject.por.fl_str_mv |
subclinical hypothyroidism thyrotropin-releasing hormone thyroid function tests |
topic |
subclinical hypothyroidism thyrotropin-releasing hormone thyroid function tests |
description |
ABSTRACT Subclinical hypothyroidism (SCH) is defined by elevated thyroid-stimulating hormone (TSH) with normal free thyroxine (FT4). We aimed to evaluate the thyrotropin-releasing hormone (TRH) stimulation test in patients with repeatedly elevated TSH (up to 10 mIU/l) and normal FT4, but without apparent thyroid disease. Women with TSH > 4.5 and ≤ 10 mIU/l (in two measurements) and normal FT4 were selected. Women with a known non-thyroid cause of TSH elevation, those treated with anti-thyroid drugs, amiodarone, lithium, and those with a history of thyroidectomy, neck radiotherapy and 131I treatment were excluded. Seventy women had negative antithyroperoxidase antibodies. Ultrasonography revealed a eutopic thyroid, usual echogenicity, and a volume ≤ 15 ml, and they underwent the TRH stimulation test during initial evaluation. After stimulation with TRH, TSH > 30 mIU/l was observed in 38 women (expected response), while 32 women had TSH < 20 mIU/l (inadequate response). Age, basal TSH or thyroid volume did not differ between both groups, but FT4 concentrations were significantly lower in the first group. Follow-up was available for 66/70 women. Seven women developed a need for levothyroxine, all of them in the group with an adequate response to TRH [7/36 (19.4%) versus 0/30]. The results suggest that some cases of TSH elevation (even persistent) do not represent the early stage of thyroid insufficiency. |
publishDate |
2020 |
dc.date.none.fl_str_mv |
2020-01-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1676-24442020000100425 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1676-24442020000100425 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.5935/1676-2444.20200043 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira de Patologia Clínica |
publisher.none.fl_str_mv |
Sociedade Brasileira de Patologia Clínica |
dc.source.none.fl_str_mv |
Jornal Brasileiro de Patologia e Medicina Laboratorial v.56 2020 reponame:Jornal Brasileiro de Patologia e Medicina Laboratorial (Online) instname:Sociedade Brasileira de Patologia (SBP) instacron:SBP |
instname_str |
Sociedade Brasileira de Patologia (SBP) |
instacron_str |
SBP |
institution |
SBP |
reponame_str |
Jornal Brasileiro de Patologia e Medicina Laboratorial (Online) |
collection |
Jornal Brasileiro de Patologia e Medicina Laboratorial (Online) |
repository.name.fl_str_mv |
Jornal Brasileiro de Patologia e Medicina Laboratorial (Online) - Sociedade Brasileira de Patologia (SBP) |
repository.mail.fl_str_mv |
||jbpml@sbpc.org.br |
_version_ |
1752122297644220416 |