Homogeneity study of the internal quality control sera for immunodiagnosis of HIV/AIDS
Autor(a) principal: | |
---|---|
Data de Publicação: | 2014 |
Outros Autores: | , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Jornal Brasileiro de Patologia e Medicina Laboratorial (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1676-24442014000100046 |
Resumo: | Introduction: The present study reports the data from the first homogeneity assessment of samples composing the serum panels produced at the Immunology Center of Instituto Adolfo Lutz, São Paulo. These samples have been distributed to the public laboratories and those partaking in the Brazilian Unified Health System, and to the participants in the Internal Quality Control Program for human immunodeficiency virus (HIV) antibody (Ab) testing. Objective: To assess the homogeneity of serum samples in panels from different lots for HIV/acquired immunodeficiency syndrome (AIDS) immunodiagnosis by using the statistical method to ensure quality of the reference material. Method: Sera homogeneity was evaluated by means of enzyme-linked immunoassay/enzyme immunoassay (ELISA/EIA) for detection of HIV Ab, and the one-way analysis of variance was employed for analyzing the data. No statistically significant differences were found among the several serum vials. Conclusion: The sera dispensed in the vials were homogeneous in the respective lots. |
id |
SBP-1_b2673268cf09c3d40a83c23e25bd55d5 |
---|---|
oai_identifier_str |
oai:scielo:S1676-24442014000100046 |
network_acronym_str |
SBP-1 |
network_name_str |
Jornal Brasileiro de Patologia e Medicina Laboratorial (Online) |
repository_id_str |
|
spelling |
Homogeneity study of the internal quality control sera for immunodiagnosis of HIV/AIDSreference materialHIVquality controlimmunoenzyme techniques Introduction: The present study reports the data from the first homogeneity assessment of samples composing the serum panels produced at the Immunology Center of Instituto Adolfo Lutz, São Paulo. These samples have been distributed to the public laboratories and those partaking in the Brazilian Unified Health System, and to the participants in the Internal Quality Control Program for human immunodeficiency virus (HIV) antibody (Ab) testing. Objective: To assess the homogeneity of serum samples in panels from different lots for HIV/acquired immunodeficiency syndrome (AIDS) immunodiagnosis by using the statistical method to ensure quality of the reference material. Method: Sera homogeneity was evaluated by means of enzyme-linked immunoassay/enzyme immunoassay (ELISA/EIA) for detection of HIV Ab, and the one-way analysis of variance was employed for analyzing the data. No statistically significant differences were found among the several serum vials. Conclusion: The sera dispensed in the vials were homogeneous in the respective lots. Sociedade Brasileira de Patologia Clínica2014-02-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1676-24442014000100046Jornal Brasileiro de Patologia e Medicina Laboratorial v.50 n.1 2014reponame:Jornal Brasileiro de Patologia e Medicina Laboratorial (Online)instname:Sociedade Brasileira de Patologia (SBP)instacron:SBP10.1590/S1676-24442014000100006info:eu-repo/semantics/openAccessCastejon,Márcia JorgeYamashiro,RosemeireOliveira,Camila Cardoso deOlivieri,José CarlosOliveira,Carmem Aparecida de FreitasUeda,Mirtheseng2014-03-31T00:00:00Zoai:scielo:S1676-24442014000100046Revistahttp://www.scielo.br/jbpmlhttps://old.scielo.br/oai/scielo-oai.php||jbpml@sbpc.org.br1678-47741676-2444opendoar:2014-03-31T00:00Jornal Brasileiro de Patologia e Medicina Laboratorial (Online) - Sociedade Brasileira de Patologia (SBP)false |
dc.title.none.fl_str_mv |
Homogeneity study of the internal quality control sera for immunodiagnosis of HIV/AIDS |
title |
Homogeneity study of the internal quality control sera for immunodiagnosis of HIV/AIDS |
spellingShingle |
Homogeneity study of the internal quality control sera for immunodiagnosis of HIV/AIDS Castejon,Márcia Jorge reference material HIV quality control immunoenzyme techniques |
title_short |
Homogeneity study of the internal quality control sera for immunodiagnosis of HIV/AIDS |
title_full |
Homogeneity study of the internal quality control sera for immunodiagnosis of HIV/AIDS |
title_fullStr |
Homogeneity study of the internal quality control sera for immunodiagnosis of HIV/AIDS |
title_full_unstemmed |
Homogeneity study of the internal quality control sera for immunodiagnosis of HIV/AIDS |
title_sort |
Homogeneity study of the internal quality control sera for immunodiagnosis of HIV/AIDS |
author |
Castejon,Márcia Jorge |
author_facet |
Castejon,Márcia Jorge Yamashiro,Rosemeire Oliveira,Camila Cardoso de Olivieri,José Carlos Oliveira,Carmem Aparecida de Freitas Ueda,Mirthes |
author_role |
author |
author2 |
Yamashiro,Rosemeire Oliveira,Camila Cardoso de Olivieri,José Carlos Oliveira,Carmem Aparecida de Freitas Ueda,Mirthes |
author2_role |
author author author author author |
dc.contributor.author.fl_str_mv |
Castejon,Márcia Jorge Yamashiro,Rosemeire Oliveira,Camila Cardoso de Olivieri,José Carlos Oliveira,Carmem Aparecida de Freitas Ueda,Mirthes |
dc.subject.por.fl_str_mv |
reference material HIV quality control immunoenzyme techniques |
topic |
reference material HIV quality control immunoenzyme techniques |
description |
Introduction: The present study reports the data from the first homogeneity assessment of samples composing the serum panels produced at the Immunology Center of Instituto Adolfo Lutz, São Paulo. These samples have been distributed to the public laboratories and those partaking in the Brazilian Unified Health System, and to the participants in the Internal Quality Control Program for human immunodeficiency virus (HIV) antibody (Ab) testing. Objective: To assess the homogeneity of serum samples in panels from different lots for HIV/acquired immunodeficiency syndrome (AIDS) immunodiagnosis by using the statistical method to ensure quality of the reference material. Method: Sera homogeneity was evaluated by means of enzyme-linked immunoassay/enzyme immunoassay (ELISA/EIA) for detection of HIV Ab, and the one-way analysis of variance was employed for analyzing the data. No statistically significant differences were found among the several serum vials. Conclusion: The sera dispensed in the vials were homogeneous in the respective lots. |
publishDate |
2014 |
dc.date.none.fl_str_mv |
2014-02-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1676-24442014000100046 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1676-24442014000100046 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/S1676-24442014000100006 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira de Patologia Clínica |
publisher.none.fl_str_mv |
Sociedade Brasileira de Patologia Clínica |
dc.source.none.fl_str_mv |
Jornal Brasileiro de Patologia e Medicina Laboratorial v.50 n.1 2014 reponame:Jornal Brasileiro de Patologia e Medicina Laboratorial (Online) instname:Sociedade Brasileira de Patologia (SBP) instacron:SBP |
instname_str |
Sociedade Brasileira de Patologia (SBP) |
instacron_str |
SBP |
institution |
SBP |
reponame_str |
Jornal Brasileiro de Patologia e Medicina Laboratorial (Online) |
collection |
Jornal Brasileiro de Patologia e Medicina Laboratorial (Online) |
repository.name.fl_str_mv |
Jornal Brasileiro de Patologia e Medicina Laboratorial (Online) - Sociedade Brasileira de Patologia (SBP) |
repository.mail.fl_str_mv |
||jbpml@sbpc.org.br |
_version_ |
1752122295902535680 |