Evaluation of MALDI-TOF mass spectrometry (VITEK-MS) compared to the ANC card (VITEK 2) for the identification of clinically significant anaerobes

Detalhes bibliográficos
Autor(a) principal: Tsukimoto,Eliane R.
Data de Publicação: 2018
Outros Autores: Rossi,Flávia
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Jornal Brasileiro de Patologia e Medicina Laboratorial (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1676-24442018000400206
Resumo: ABSTRACT Introduction: The identification of anaerobic bacteria by conventional methods employed in clinical laboratories requires a lot of work and a long response time [turnaround time (TAT)]. Matrix assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) is an accurate, rapid and inexpensive technique with promising results for bacterial identification. Objective: To evaluate the MALDI-TOF mass spectrometry (VITEK-MS, bioMérieux, France) compared to the ANC card (VITEK 2, bioMérieux, France) for the identification of anaerobes, and also veriying the cost variation between both methodologies. Methods: 421 anaerobes were concomitantly identified by ANC (VITEK 2) and MALDI-TOF (VITEK MS). The conflicting results or those presenting low differentiation of the species were subjected to the 16S ribosomal ribonucleic acid (rRNA) sequencing. Results: Thirty-five strains were not identified by ANC (VITEK 2), and only one isolate was not identified by MALDI-TOF (VITEK MS). From the 386 anaerobes identified by the two methodologies, 97% agreement was observed on the identification of genus and species between the methodologies. Thirteen (3%) isolates were submitted to 16S sequencing. The agreement observed was 70% using ANC (VITEK 2) using 92% by MALDI-TOF (VITEK MS). Conclusion: Both methodologies showed an excellent performance for the identification of the strains tested with great differences in relation to cost-benefit. MALDI-TOF MS allowed 35 additional identifications and a saving of BRL$ 7,786 with the release of culture positive result five days ahead of the ANC (VITEK 2). TAT reduction may contribute to a successful clinical resolution.
id SBP-1_b5d1959e0a28d1d370c6620c6ea8ec90
oai_identifier_str oai:scielo:S1676-24442018000400206
network_acronym_str SBP-1
network_name_str Jornal Brasileiro de Patologia e Medicina Laboratorial (Online)
repository_id_str
spelling Evaluation of MALDI-TOF mass spectrometry (VITEK-MS) compared to the ANC card (VITEK 2) for the identification of clinically significant anaerobesmatrix assisted laser desorption ionization-time of flight mass spectrometryclinical laboratory techniquesbacteroides infectionsanaerobic bacteriaClostridium infectionsABSTRACT Introduction: The identification of anaerobic bacteria by conventional methods employed in clinical laboratories requires a lot of work and a long response time [turnaround time (TAT)]. Matrix assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) is an accurate, rapid and inexpensive technique with promising results for bacterial identification. Objective: To evaluate the MALDI-TOF mass spectrometry (VITEK-MS, bioMérieux, France) compared to the ANC card (VITEK 2, bioMérieux, France) for the identification of anaerobes, and also veriying the cost variation between both methodologies. Methods: 421 anaerobes were concomitantly identified by ANC (VITEK 2) and MALDI-TOF (VITEK MS). The conflicting results or those presenting low differentiation of the species were subjected to the 16S ribosomal ribonucleic acid (rRNA) sequencing. Results: Thirty-five strains were not identified by ANC (VITEK 2), and only one isolate was not identified by MALDI-TOF (VITEK MS). From the 386 anaerobes identified by the two methodologies, 97% agreement was observed on the identification of genus and species between the methodologies. Thirteen (3%) isolates were submitted to 16S sequencing. The agreement observed was 70% using ANC (VITEK 2) using 92% by MALDI-TOF (VITEK MS). Conclusion: Both methodologies showed an excellent performance for the identification of the strains tested with great differences in relation to cost-benefit. MALDI-TOF MS allowed 35 additional identifications and a saving of BRL$ 7,786 with the release of culture positive result five days ahead of the ANC (VITEK 2). TAT reduction may contribute to a successful clinical resolution.Sociedade Brasileira de Patologia Clínica2018-07-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1676-24442018000400206Jornal Brasileiro de Patologia e Medicina Laboratorial v.54 n.4 2018reponame:Jornal Brasileiro de Patologia e Medicina Laboratorial (Online)instname:Sociedade Brasileira de Patologia (SBP)instacron:SBP10.5935/1676-2444.20180036info:eu-repo/semantics/openAccessTsukimoto,Eliane R.Rossi,Fláviaeng2018-09-20T00:00:00Zoai:scielo:S1676-24442018000400206Revistahttp://www.scielo.br/jbpmlhttps://old.scielo.br/oai/scielo-oai.php||jbpml@sbpc.org.br1678-47741676-2444opendoar:2018-09-20T00:00Jornal Brasileiro de Patologia e Medicina Laboratorial (Online) - Sociedade Brasileira de Patologia (SBP)false
dc.title.none.fl_str_mv Evaluation of MALDI-TOF mass spectrometry (VITEK-MS) compared to the ANC card (VITEK 2) for the identification of clinically significant anaerobes
title Evaluation of MALDI-TOF mass spectrometry (VITEK-MS) compared to the ANC card (VITEK 2) for the identification of clinically significant anaerobes
spellingShingle Evaluation of MALDI-TOF mass spectrometry (VITEK-MS) compared to the ANC card (VITEK 2) for the identification of clinically significant anaerobes
Tsukimoto,Eliane R.
matrix assisted laser desorption ionization-time of flight mass spectrometry
clinical laboratory techniques
bacteroides infections
anaerobic bacteria
Clostridium infections
title_short Evaluation of MALDI-TOF mass spectrometry (VITEK-MS) compared to the ANC card (VITEK 2) for the identification of clinically significant anaerobes
title_full Evaluation of MALDI-TOF mass spectrometry (VITEK-MS) compared to the ANC card (VITEK 2) for the identification of clinically significant anaerobes
title_fullStr Evaluation of MALDI-TOF mass spectrometry (VITEK-MS) compared to the ANC card (VITEK 2) for the identification of clinically significant anaerobes
title_full_unstemmed Evaluation of MALDI-TOF mass spectrometry (VITEK-MS) compared to the ANC card (VITEK 2) for the identification of clinically significant anaerobes
title_sort Evaluation of MALDI-TOF mass spectrometry (VITEK-MS) compared to the ANC card (VITEK 2) for the identification of clinically significant anaerobes
author Tsukimoto,Eliane R.
author_facet Tsukimoto,Eliane R.
Rossi,Flávia
author_role author
author2 Rossi,Flávia
author2_role author
dc.contributor.author.fl_str_mv Tsukimoto,Eliane R.
Rossi,Flávia
dc.subject.por.fl_str_mv matrix assisted laser desorption ionization-time of flight mass spectrometry
clinical laboratory techniques
bacteroides infections
anaerobic bacteria
Clostridium infections
topic matrix assisted laser desorption ionization-time of flight mass spectrometry
clinical laboratory techniques
bacteroides infections
anaerobic bacteria
Clostridium infections
description ABSTRACT Introduction: The identification of anaerobic bacteria by conventional methods employed in clinical laboratories requires a lot of work and a long response time [turnaround time (TAT)]. Matrix assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) is an accurate, rapid and inexpensive technique with promising results for bacterial identification. Objective: To evaluate the MALDI-TOF mass spectrometry (VITEK-MS, bioMérieux, France) compared to the ANC card (VITEK 2, bioMérieux, France) for the identification of anaerobes, and also veriying the cost variation between both methodologies. Methods: 421 anaerobes were concomitantly identified by ANC (VITEK 2) and MALDI-TOF (VITEK MS). The conflicting results or those presenting low differentiation of the species were subjected to the 16S ribosomal ribonucleic acid (rRNA) sequencing. Results: Thirty-five strains were not identified by ANC (VITEK 2), and only one isolate was not identified by MALDI-TOF (VITEK MS). From the 386 anaerobes identified by the two methodologies, 97% agreement was observed on the identification of genus and species between the methodologies. Thirteen (3%) isolates were submitted to 16S sequencing. The agreement observed was 70% using ANC (VITEK 2) using 92% by MALDI-TOF (VITEK MS). Conclusion: Both methodologies showed an excellent performance for the identification of the strains tested with great differences in relation to cost-benefit. MALDI-TOF MS allowed 35 additional identifications and a saving of BRL$ 7,786 with the release of culture positive result five days ahead of the ANC (VITEK 2). TAT reduction may contribute to a successful clinical resolution.
publishDate 2018
dc.date.none.fl_str_mv 2018-07-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1676-24442018000400206
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1676-24442018000400206
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.5935/1676-2444.20180036
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv
Sociedade Brasileira de Patologia Clínica
publisher.none.fl_str_mv
Sociedade Brasileira de Patologia Clínica
dc.source.none.fl_str_mv Jornal Brasileiro de Patologia e Medicina Laboratorial v.54 n.4 2018
reponame:Jornal Brasileiro de Patologia e Medicina Laboratorial (Online)
instname:Sociedade Brasileira de Patologia (SBP)
instacron:SBP
instname_str Sociedade Brasileira de Patologia (SBP)
instacron_str SBP
institution SBP
reponame_str Jornal Brasileiro de Patologia e Medicina Laboratorial (Online)
collection Jornal Brasileiro de Patologia e Medicina Laboratorial (Online)
repository.name.fl_str_mv Jornal Brasileiro de Patologia e Medicina Laboratorial (Online) - Sociedade Brasileira de Patologia (SBP)
repository.mail.fl_str_mv ||jbpml@sbpc.org.br
_version_ 1752122297125175296