Diagnostic accuracy of lung ultrasound for transient tachypnea: a meta-analysis

Detalhes bibliográficos
Autor(a) principal: Wang,Yueqi
Data de Publicação: 2022
Outros Autores: Li,Na, Qu,Yangming
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Jornal de Pediatria (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0021-75572022000400329
Resumo: Abstract Objective: The objective of this meta-analysis was to study the diagnostic value of lung ultrasound (LUS) for transient tachypnea of the newborn (TTN). Methods: Embase, Cochrane Library, PubMed, Web of Science, and Google Scholar were searched, and the last search date was October 31, 2020. Studies on the diagnostic accuracy of pulmonary ultrasound for transient tachypnea were included. The quality assessment of the included study was assessed using the Diagnostic Accuracy Studies-2 tool. A meta-analysis was performed using Meta-Disc 1.4. A random-effects model was used and subgroup analysis was carried out to identify possible sources of heterogeneity. Results: A total of 378 articles were retrieved and nine studies with 3239 patients were included in the present meta-analysis. The overall quality of the included studies was moderate to high. The result of threshold analysis shows that there was no threshold effect. However, there was a significant heterogeneity caused by non-threshold effects in the included studies. A random-effects model was used. The pooled sensitivity, specificity, PLR and NLR were 0.55 (95% CI: 0.51-0.58), 0.98 (95% CI: 0.98-0.99), 58.30 (95% CI: 14.05-241.88) and 0.28 (95% CI: 0.18-0.43). The pooled DOR and AUC were 689.12 (95% CI: 68.71 to 6911.79) and 0.994. The results of subgroup analysis showed that the LUS diagnostic criteria and gold standard might be responsible for heterogeneity. Choosing "DLP combined with B line" as the diagnostic standard of LUS and choosing CXR as the gold standard could significantly improve the diagnostic performance of LUS. Conclusion: LUS is a promising method to diagnose TTN. Only DLP is not enough to diagnose TTN, while DLP combined with B-line has good diagnostic performance.
id SBPE-1_53aa8e45cb2eb52898c8fa0fd8ee0190
oai_identifier_str oai:scielo:S0021-75572022000400329
network_acronym_str SBPE-1
network_name_str Jornal de Pediatria (Online)
repository_id_str
spelling Diagnostic accuracy of lung ultrasound for transient tachypnea: a meta-analysisTransient tachypneaLung ultrasoundDiagnosisMeta-analysisAbstract Objective: The objective of this meta-analysis was to study the diagnostic value of lung ultrasound (LUS) for transient tachypnea of the newborn (TTN). Methods: Embase, Cochrane Library, PubMed, Web of Science, and Google Scholar were searched, and the last search date was October 31, 2020. Studies on the diagnostic accuracy of pulmonary ultrasound for transient tachypnea were included. The quality assessment of the included study was assessed using the Diagnostic Accuracy Studies-2 tool. A meta-analysis was performed using Meta-Disc 1.4. A random-effects model was used and subgroup analysis was carried out to identify possible sources of heterogeneity. Results: A total of 378 articles were retrieved and nine studies with 3239 patients were included in the present meta-analysis. The overall quality of the included studies was moderate to high. The result of threshold analysis shows that there was no threshold effect. However, there was a significant heterogeneity caused by non-threshold effects in the included studies. A random-effects model was used. The pooled sensitivity, specificity, PLR and NLR were 0.55 (95% CI: 0.51-0.58), 0.98 (95% CI: 0.98-0.99), 58.30 (95% CI: 14.05-241.88) and 0.28 (95% CI: 0.18-0.43). The pooled DOR and AUC were 689.12 (95% CI: 68.71 to 6911.79) and 0.994. The results of subgroup analysis showed that the LUS diagnostic criteria and gold standard might be responsible for heterogeneity. Choosing "DLP combined with B line" as the diagnostic standard of LUS and choosing CXR as the gold standard could significantly improve the diagnostic performance of LUS. Conclusion: LUS is a promising method to diagnose TTN. Only DLP is not enough to diagnose TTN, while DLP combined with B-line has good diagnostic performance.Sociedade Brasileira de Pediatria2022-07-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0021-75572022000400329Jornal de Pediatria v.98 n.4 2022reponame:Jornal de Pediatria (Online)instname:Sociedade Brasileira de Pediatria (SBP)instacron:SBPE10.1016/j.jped.2021.10.003info:eu-repo/semantics/openAccessWang,YueqiLi,NaQu,Yangmingeng2022-07-20T00:00:00Zoai:scielo:S0021-75572022000400329Revistahttp://www.jped.com.br/https://old.scielo.br/oai/scielo-oai.php||jped@jped.com.br1678-47820021-7557opendoar:2022-07-20T00:00Jornal de Pediatria (Online) - Sociedade Brasileira de Pediatria (SBP)false
dc.title.none.fl_str_mv Diagnostic accuracy of lung ultrasound for transient tachypnea: a meta-analysis
title Diagnostic accuracy of lung ultrasound for transient tachypnea: a meta-analysis
spellingShingle Diagnostic accuracy of lung ultrasound for transient tachypnea: a meta-analysis
Wang,Yueqi
Transient tachypnea
Lung ultrasound
Diagnosis
Meta-analysis
title_short Diagnostic accuracy of lung ultrasound for transient tachypnea: a meta-analysis
title_full Diagnostic accuracy of lung ultrasound for transient tachypnea: a meta-analysis
title_fullStr Diagnostic accuracy of lung ultrasound for transient tachypnea: a meta-analysis
title_full_unstemmed Diagnostic accuracy of lung ultrasound for transient tachypnea: a meta-analysis
title_sort Diagnostic accuracy of lung ultrasound for transient tachypnea: a meta-analysis
author Wang,Yueqi
author_facet Wang,Yueqi
Li,Na
Qu,Yangming
author_role author
author2 Li,Na
Qu,Yangming
author2_role author
author
dc.contributor.author.fl_str_mv Wang,Yueqi
Li,Na
Qu,Yangming
dc.subject.por.fl_str_mv Transient tachypnea
Lung ultrasound
Diagnosis
Meta-analysis
topic Transient tachypnea
Lung ultrasound
Diagnosis
Meta-analysis
description Abstract Objective: The objective of this meta-analysis was to study the diagnostic value of lung ultrasound (LUS) for transient tachypnea of the newborn (TTN). Methods: Embase, Cochrane Library, PubMed, Web of Science, and Google Scholar were searched, and the last search date was October 31, 2020. Studies on the diagnostic accuracy of pulmonary ultrasound for transient tachypnea were included. The quality assessment of the included study was assessed using the Diagnostic Accuracy Studies-2 tool. A meta-analysis was performed using Meta-Disc 1.4. A random-effects model was used and subgroup analysis was carried out to identify possible sources of heterogeneity. Results: A total of 378 articles were retrieved and nine studies with 3239 patients were included in the present meta-analysis. The overall quality of the included studies was moderate to high. The result of threshold analysis shows that there was no threshold effect. However, there was a significant heterogeneity caused by non-threshold effects in the included studies. A random-effects model was used. The pooled sensitivity, specificity, PLR and NLR were 0.55 (95% CI: 0.51-0.58), 0.98 (95% CI: 0.98-0.99), 58.30 (95% CI: 14.05-241.88) and 0.28 (95% CI: 0.18-0.43). The pooled DOR and AUC were 689.12 (95% CI: 68.71 to 6911.79) and 0.994. The results of subgroup analysis showed that the LUS diagnostic criteria and gold standard might be responsible for heterogeneity. Choosing "DLP combined with B line" as the diagnostic standard of LUS and choosing CXR as the gold standard could significantly improve the diagnostic performance of LUS. Conclusion: LUS is a promising method to diagnose TTN. Only DLP is not enough to diagnose TTN, while DLP combined with B-line has good diagnostic performance.
publishDate 2022
dc.date.none.fl_str_mv 2022-07-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0021-75572022000400329
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0021-75572022000400329
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1016/j.jped.2021.10.003
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Pediatria
publisher.none.fl_str_mv Sociedade Brasileira de Pediatria
dc.source.none.fl_str_mv Jornal de Pediatria v.98 n.4 2022
reponame:Jornal de Pediatria (Online)
instname:Sociedade Brasileira de Pediatria (SBP)
instacron:SBPE
instname_str Sociedade Brasileira de Pediatria (SBP)
instacron_str SBPE
institution SBPE
reponame_str Jornal de Pediatria (Online)
collection Jornal de Pediatria (Online)
repository.name.fl_str_mv Jornal de Pediatria (Online) - Sociedade Brasileira de Pediatria (SBP)
repository.mail.fl_str_mv ||jped@jped.com.br
_version_ 1752122323304972288